본문 바로가기
KERD
논문KCI 등재

Predictors of Continuous Positive Airway Pressure Adherence and Comparison of Clinical Factors and Polysomnography Findings Between Compliant and Non-Compliant Korean Adults With Obstructive Sleep Apnea

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류정신과학

초록

Objective Continuous positive airway pressure (CPAP) is the preferred treatment for obstructive sleep apnea (OSA). However, compliance with CPAP therapy varies among studies, and studies on its predictors are insufficient in Korea. This study aimed to identify factors that predict compliance with CPAP therapy in patients with OSA.Methods We retrospectively reviewed medical records, polysomnography (PSG) records, and self-report questionnaires of patients w ith OSA. Criteria for compliance was the use of CPAP devices for ≥4 h per night for ≥70% of the consecutive 30 nights (i.e., 21 days) during the first 3 months of treatment initiation. The patients were classified into two groups: compliant and non-compliant. Logistic regression analyses were performed to identify the clinical factors and PSG parameters associated with CPAP compliance.Results Of the 188 participants, 80 were classified into the compliant group and 108 into the non-compliant group. The ratios of stage N1 (p=0.011) and health insurance coverage (p=0.007) were significantly associated with compliance with CPAP, with an explanatory power of 18.6% (R<sup>2</sup>=0.186, p<0.001).Conclusion Stage N1 ratio and health insurance coverage were significant predictors of CPAP compliance. It is necessary to confirm whether the relationship between a high stage N1 ratio and compliance can be reproduced in a larger sample and in individuals from other countries.

Abstract

Objective Continuous positive airway pressure (CPAP) is the preferred treatment for obstructive sleep apnea (OSA). However, compliance with CPAP therapy varies among studies, and studies on its predictors are insufficient in Korea. This study aimed to identify factors that predict compliance with CPAP therapy in patients with OSA.Methods We retrospectively reviewed medical records, polysomnography (PSG) records, and self-report questionnaires of patients w ith OSA. Criteria for compliance was the use of CPAP devices for ≥4 h per night for ≥70% of the consecutive 30 nights (i.e., 21 days) during the first 3 months of treatment initiation. The patients were classified into two groups: compliant and non-compliant. Logistic regression analyses were performed to identify the clinical factors and PSG parameters associated with CPAP compliance.Results Of the 188 participants, 80 were classified into the compliant group and 108 into the non-compliant group. The ratios of stage N1 (p=0.011) and health insurance coverage (p=0.007) were significantly associated with compliance with CPAP, with an explanatory power of 18.6% (R<sup>2</sup>=0.186, p<0.001).Conclusion Stage N1 ratio and health insurance coverage were significant predictors of CPAP compliance. It is necessary to confirm whether the relationship between a high stage N1 ratio and compliance can be reproduced in a larger sample and in individuals from other countries.

참고문헌 (45)

  1. Greenberg H, "Principles and practice of sleep medicine", pp.110~1124 (2017), Elsevier
  2. Anders TF, "Sleep and sleepiness in chil dren and adolescents", Pediatr Clin North Am, 27, pp.29~43 (1980)
  3. Freedman NS, "Primary care sleep medicine (current clinical practice)", pp.131~146 (2007), man Press
  4. Holty JE, "Surgical options for the treatment of ob structive sleep apnea", Med Clin North Am, 94, pp.479~515 (2010)
  5. Campos-Rodriguez F, "Long-term effect of continuous posi tive airway pressure on BP in patients with hypertension and sleep ap nea", Chest, 132, pp.1847~1852 (2007)
  6. Marin JM, "Long-term cardiovascular outcomes in men with obstructive sleep apnoea-hypopnoea with or without treatment with continuous positive airway pressure : an obser vational study", Lancet, 365, pp.1046~1053 (2005)
  7. Parthasarathy S, "A multicenter prospective comparative effectiveness study of the effect of physician certification and center accreditation on patient-centered outcomes in obstructive sleep apnea", J Clin Sleep Med, 10, pp.243~249 (2014)
  8. Kribbs NB, "Objective measurement of patterns of nasal CPAP use by patients with obstructive sleep apnea", Am Rev Respir Dis, 147, pp.887~895 (1993)
  9. McArdle N, "Long-term use of CPAP therapy for sleep apnea", hypopnea syndrome, 1999, pp.159(4 Pt 1), 1108~1114
  10. Choi JA, "Subjective and objective CPAP com pliance in patients with obstructive sleep apnea syndrome", Sleep Med Res, 2, pp.63~68 (2011)
  11. Wang JH, "Compliance of auto-ad justing positive airway pressure in Korean obstructive sleep apnea pa tients", J Rhinol, 13, pp.92~96 (2006)
  12. Pieh C, "Insomnia symptoms influence CPAP compliance", Sleep Breath, 17, pp.99~104 (2013)
  13. Massie CA, "Effects of humidification on nasal symptoms and compliance in sleep apnea patients using con tinuous positive airway pressure", Chest, 116, pp.403~408 (1999)
  14. Philip P, "Spe cific insomnia symptoms and self-efficacy explain CPAP compliance in a sample of OSAS patients", PLoS One, 13, pp.e0195343~ (2018)
  15. Lewis KE, "Early predictors of CPAP use for the treatment of obstructive sleep apnea", Sleep, 27, pp.134~138 (2004)
  16. Kwon OE, "Various factors affecting short-term com pliance rates of CPAP in OSA patients : in the age of insurance coverage in Korea", J Rhinol, 28, pp.36~43 (2021)
  17. Collen J, "Clinical and polysomnographic predictors of short-term continuous positive airway pressure compli ance", Chest, 135, pp.704~709 (2009)
  18. Platt AB, "Neigh borhood of residence is associated with daily adherence to CPAP ther apy", Sleep, 32, pp.799~806 (2009)
  19. American Academy of Sleep Medicine, "International classification of sleep disorders-third edition(ICSD-3)" (2014), American Academy of Sleep Medicine
  20. Sohn SI, "The reliability and validity of the Korean version of the Pittsburgh Sleep Quality Index", Sleep Breath, 16, pp.803~812 (2012)
  21. Cho YW, "Validation of a Korean version of the insomnia severity index", J Clin Neurol, 10, pp.210~215 (2014)
  22. Cho YW, "The reliability and validity of the Korean version of the Epworth sleepiness scale", Sleep Breath, 15, pp.377~384 (2011)
  23. Rhee MK, "A standardization study of Beck Depression Inventory 1-Korean version(K-BDI) : reliability and factor analysis", Kor J Psychopathol, 4, pp.7795~ (1995)
  24. Iber C, "The AASM manual for the scoring of sleep and associated events : rules, terminology and technical specification" (2007), American Academy of Sleep Medicine
  25. Zampogna E, "Adherence to continuous positive airway pressure in patients with obstructive sleep apnoea. A ten year real life study", Respir Med, 150, pp.95~100 (2019)
  26. Tan B, "Adherence to con tinuous positive airway pressure therapy in Singaporean patients with obstructive sleep apnea", Am J Otolaryngol, 39, pp.501~506 (2018)
  27. Kim MJ, "Predictors of adherence with positive airway pressure treatment in patients with obstructive sleep apnea in Korean", J Rhinol, 22, pp.89~95 (2015)
  28. Park P, "Influencing factors on CPAP adherence and anatomic characteristics of upper air way in OSA subjects", Medicine(Baltimore), 96, pp.e8818~ (2017)
  29. Tsuyumu M, "Ten-year adherence to continuous positive airway pressure treatment in patients with moderate-to-severe obstructive sleep apnea", Sleep Breath, 24, pp.1565~1571 (2020)
  30. Campos-Rodriguez F, "Long-term adherence to continuous positive airway pressure therapy in non-sleepy sleep apnea patients", Sleep Med, 17, pp.1~6 (2016)
  31. Nsair A, "Factors influ encing adherence to auto-CPAP : an observational monocentric study comparing patients with and without cardiovascular diseases", Front Neurol, 10, pp.801~ (2019)
  32. Lee CHK, "Acceptance and adher ence to continuous positive airway pressure therapy in patients with obstructive sleep apnea(OSA)in a Southeast Asian privately funded healthcare system", Sleep Sci, 10, pp.57~63 (2017)
  33. Florés M, "Predictors of long-term adherence to continuous positive airway pressure in patients with obstructive sleep apnoea and acute coronary syndrome", J Thorac Dis, 10(Suppl 1), pp.S124~S134 (2018)
  34. Palm A, "Factors influencing adherence to continuous positive air way pressure treatment in obstructive sleep apnea and mortality asso ciated with treatment failure-a national registry-based cohort study", Sleep Med, 51, pp.85~91 (2018)
  35. Wallace DM, "Determi nants of continuous positive airway pressure adherence in a sleep clinic cohort of South Florida Hispanic veterans", Sleep Breath, 17, pp.351363~ (2013)
  36. Drake CL, "Sleep during titration predicts continuous positive airway pressure compli ance", Sleep, 26, pp.308~311 (2003)
  37. Shirahata T, "Improvement of sleep parameters by titration polysomnography could predict adherence to positive airway pressure therapy in obstruc tive sleep apnea", J Clin Sleep Med, 19, pp.1465~1473 (2023)
  38. Madbouly EM, "T he role of severity of obstructive sleep apnea measured by apnea-hy popnea index in predicting compliance with pressure therapy, a meta analysis", Am J Ther, 21, pp.260~264 (2014)
  39. Turnbull CD, "In patients with minimally symptomatic OSA can baseline characteristics and ear ly patterns of CPAP usage predict those who are likely to be longer-term users of CPAP", J Thorac Dis, 8, pp.276~281 (2016)
  40. Wallace DM, "Comorbid insomnia symptoms predict lower 6-month adherence to CPAP in US veterans with ob structive sleep apnea", Sleep Breath, 22, pp.5~15 (2018)
  41. Wickwire EM, "Sleep maintenance insomnia complaints predict poor CPAP adherence : a clinical case se ries", Sleep Med, 11, pp.772~776 (2010)
  42. Riachy M, "Factors predicting CPAP adherence in obstructive sleep apnea syn drome", Sleep Breath, 21, pp.295~302 (2017)
  43. Eguchi K, "Investigation on factors related to poor CPAP adherence using machine learning : a pilot study", Sci Rep, 12, pp.19563~ (2022)
  44. Campbell A, "Ethnicity and socioeconomic status pre dict initial continuous positive airway pressure compliance in New Zealand adults with obstructive sleep apnoea", Intern Med J, 42, pp.e95~e101 (2012)
  45. McMillan A, "A multicentre randomised controlled trial and economic evaluation of continuous positive airway pressure for the treatment of obstructive sleep apnoea syndrome in older people : PREDICT", Health Technol Assess, 19, pp.1~188 (2015)

관련 논문AI추천

폐쇄성 수면무호흡증 환자에서 양압기 치료에 대한 1년 이상 순응군과 비순응군의 비교금상연, 박진우, 박희준, 신승헌, 예미경, 유재호대한이비인후과학회 부산,울산,경남 지부회 · 임상이비인후과2022 · 제33권 제3호The Impact of National Health Insurance Coverage on Compliance With Positive Airway Pressure Therapy in Patients With Obstructive Sleep Apnea배미례, 정유삼, 최우리대한이비인후과학회 · Clinical and Experimental Otorhinolaryngology2022 · 제15권 제1호Adherence to Positive Airway Pressure therapy as Severity of Adult Obstructive Sleep Apnea유준, 박성민, 서민영, 이민규, 이승훈, 한문수, 황선진대한이비인후과학회 · 대한이비인후과학회지 두경부외과학2022 · 제65권 제3호양압기 처방 보험 적용에 따른 순응도김현우, 문수진, 박다희, 조규섭, 조재욱, 최성욱대한이비인후과학회 부산,울산,경남 지부회 · 임상이비인후과2022 · 제33권 제3호Improved Adherence to Positive Airway Pressure Treatment after Covering National Health Insurance in Patient with Obstructive Sleep Apnea: A Tertiary Sleep Center Review윤효은, 이호원, 전지예, 전창진, 황재춘대한수면연구학회 · Journal of sleep medicine2021 · 제18권 제1호건강 보험 적용하에 장기적으로 양압기 치료를 했던 폐쇄성 수면무호흡증 환자에서 중단 요인 분석김성동, 김현수, 박지환, 장서윤, 조규섭, 조현주대한이비인후과학회 부산,울산,경남 지부회 · 임상이비인후과2023 · 제34권 제2호

이 간행물의 다른 논문 (12건)