본문 바로가기
KERD
논문KCI 등재

남녀 청소년의 심폐지구력 평가를 위한 Step test 추정식의 일치도 평가

Assessing Agreement of Step Test Equations to Estimate VO2max in Korean Male and Female Youths Aged 13-18 Years

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE: To assess the agreement between maximal oxygen consumption (VO2max) measured directly when performing the maximal graded exercise test (GXT) and estimated VO2max from two different equations in Korean male and female youths aged 13-18 years. METHODS: Sixty-six adolescents (15.3±1.7 years, 166.0±7.8 cm, 58. 7±10.0 kg, BMI 21.2±2.7) performed GXT on a treadmill and Astrand-Ryhming step test (AR test) to measure VO2max and VO2max estimates, respectively. The participants wore a portable device (Polar CS300) to measure heart rate (HR) during the tests. RESULTS: Correlation coefficients (r) between VO2max of the equations and VO2max of the measured value were 0.321 (p<0.05) and 0.713 (P<0.01), respectively. The mean difference ranged from -0.234 mL·kg-1 ·min-1 to -3.63 mL·kg-1 ·min-1. The AR equation tended to be somewhat underestimated measured VO2max. The standard error of the estimate (SEE) ranged from 4.95 mL·kg-1 ·min-1 to 7.60 mL·kg-1 ·min-1, and the percentage error (%Error) ranged from 26.6% to 193.7%. CONCLUSIONS: The results of this study suggest that the equation provides the closet agreement with directly measured VO2max in Korean male and female youths aged 13-18 years. A further study needs to develop a step test estimation equation targeting adults and elderly people in which validity and reliability are secured.

Abstract

PURPOSE: To assess the agreement between maximal oxygen consumption (VO2max) measured directly when performing the maximal graded exercise test (GXT) and estimated VO2max from two different equations in Korean male and female youths aged 13-18 years. METHODS: Sixty-six adolescents (15.3±1.7 years, 166.0±7.8 cm, 58. 7±10.0 kg, BMI 21.2±2.7) performed GXT on a treadmill and Astrand-Ryhming step test (AR test) to measure VO2max and VO2max estimates, respectively. The participants wore a portable device (Polar CS300) to measure heart rate (HR) during the tests. RESULTS: Correlation coefficients (r) between VO2max of the equations and VO2max of the measured value were 0.321 (p<0.05) and 0.713 (P<0.01), respectively. The mean difference ranged from -0.234 mL·kg-1 ·min-1 to -3.63 mL·kg-1 ·min-1. The AR equation tended to be somewhat underestimated measured VO2max. The standard error of the estimate (SEE) ranged from 4.95 mL·kg-1 ·min-1 to 7.60 mL·kg-1 ·min-1, and the percentage error (%Error) ranged from 26.6% to 193.7%. CONCLUSIONS: The results of this study suggest that the equation provides the closet agreement with directly measured VO2max in Korean male and female youths aged 13-18 years. A further study needs to develop a step test estimation equation targeting adults and elderly people in which validity and reliability are secured.

참고문헌 (28)

  1. WHO, "Global Health Risks: Mortality and burden of disease attributable to selected major risks", ~ (2009)
  2. The 12th Korea youth risk behavior survey, "Korea Centers for Disease Control and Prevention", KCDC, ~ (2016)
  3. Development of physical fitness center model Research Report, "Chung JW", Korea Institute of Sport Sciences, ~ (2014)
  4. 국민체력 100대체항목 개발, "Chung JW", ~ (2015)
  5. George JD, "VO2max estimation from a submaximal 1-mile track jog for fit college-age individuals", Med Sci Sports Exerc, 25(3), pp.401~406 (1993)
  6. Zwiren LD, "Estimation of O2max : a comparative analysis of five exercise tests", Res Q Exerc Sport, 62(1), pp.73~78 (1991)
  7. Cink RE, "Validity of the Astrand-Ryhming nomogram for predicting maximal oxygen intake", Br J Sports Med, 15(3), pp.182~185 (1981)
  8. Baek CS, "Analysis of the validity of steptest by bench heights and exercise duration", pp.1999
  9. Kim HS, "A study of validation in the use of variable bench heights in the step test", pp.2000
  10. 송정란, "남녀 청소년들(13-18세)의 VO2max 평가를 위한 Astrand- Ryhming 스텝검사 프로토콜을 기반으로 한 새로운 추정식 개발", 운동과학, 27(1), pp.71~79 (2018), 한국운동생리학회[DOI]
  11. Gellish RL, "Longitudinal modeling of the relationship between age and maximal heart rate", Med Sci Sports Exerc, 39(5), pp.822~829 (2007)
  12. Astrand PO, "A nomogram for calculation of aerobic capacity(physical fitness)from pulse rate during submaximal work", J Appl Physiol, 7(2), pp.218~221 (1954)
  13. Bland JM, "Statistical methods for assessing agreement between two methods of clinical measurement", Lancet, 8, pp.307~310 (1986)
  14. Bland JM, "Comparing methods of measurement : Why plotting difference against standard method is misleading", Lancet, 346, pp.1085~1087 (1995)
  15. Buckley J, "Reliability and validity of measures taken during the Chester step test to predict aerobic power and to prescribe aerobic exercise", Br J Sports Med, 38(2), pp.197~205 (2004)
  16. Sykes K, "The Chester step test—a simple yet effective tool for aerobic capacity", Physiotherapy, 90(1), pp.183~188 (2004)
  17. Chatterjee S, "Validity of Queen’s College step test for use with young Indian men", Br J Sports Med, 38(3), pp.289~291 (2004)
  18. Knight E, "Validation of the step test and exercise prescription tool for adults", Can J Diabetes, 38(3), pp.164~171 (2014)
  19. McArdle WD, "Reliability and interrelationships between maximal oxygen intake, physical work capacity and step-test scores in college women", Med Sci Sports, 4(4), pp.182~186 (1972)
  20. Santo AS, "Predicting maximum oxygen uptake from a modified 3-minute step test", Res Q Exerc Sport, 74(1), pp.110~115 (2003)
  21. Beutner F, "Validation of a brief step-test protocol for estimation of peak oxygen uptake", Eur J Prev Cardiol, 22(4), pp.503~512 (2015)
  22. Aandstad A, "Validity and reliability of the 20 meter shuttle run test in military personnel", Mil Med, 176(5), pp.513~518 (2011)
  23. Flouris AD, "Enhancing the efficacy of the 20 m multistage shuttle run test", Br J Sports Med, 39(3), pp.166~170 (2005)
  24. Léger L, "Validity of the 20 m shuttle run test with 1 min stages to predict V02max in adults", Can J Sport Sci, 14(1), pp.21~26 (1989)
  25. Léger LA, "The multistage 20 metre shuttle run test for aerobic fitness", J Sports Sci, 6(2), pp.93~101 (1988)
  26. Mahar MT, "Estimation of aerobic fitness from 20-m multistage shuttle run test performance", Am J Prev Med, 41(4 Suppl 2), pp.S117~S123 (2011)
  27. Ramsbottom R, "A progressive shuttle run test to estimate maximal oxygen uptake", Br J Sports Med, 22(4), pp.141~144 (1988)
  28. Stickland MK, "Prediction of maximal aerobic power from the 20-m multi-stage shuttle run test", Can J AppI Physiol, 28(2), pp.272~282 (2003)

관련 논문AI추천

이 간행물의 다른 논문 (11건)