서울 지하철 내 공기 중 먼지의 특성에 관한 연구
A Study on Characteristics of Airborne Dusts in SeoulSubway Stations
1
조회
0
다운로드
6
인용
0
참고문헌
초록
Abstract
The purpose of this study was to evaluate airborne concentrations and characteristics of TSP, IPM, TPM and RPM in Seoul subway stations. Sampling was performed at 14 stations from April 11 to 29, 2002. Size-selective dust concentrations and metal concentrations were measured by gravimetric method and ICP-AES, respectively. The geometric mean of TSP, IPM, TPM and RPM concentrations in Seoul subway stations were 176 mg/m3, 348 mg/m3, 158 mg/m3 and 104 mg/m3, respectively. Dust concentrations in pathway were the highest and those in lobby were the lowest. The size distribution of dusts was significantly different by location of collection. When the deposition rate into pulmonary gas exchange region was estimated by size distribution, the deposition rate of dust collected from platform was higher than those of dust collected from lobby and pathway. The lower the basement levels were, the higher the deposition rates of dusts into tracheobronchial region and gas exchange region were. Copper and iron concentrations measured in platform higher were than those in other areas.
참고문헌 (18)
- "다중이용시설등의실내공기질관리법시행규칙", (156) (2004), 환경부령
- "Rationale for particle size-selective aerosol sampling. In", pp.3~27 (1999), ACGIH
- "PM 2.5 Ambient Air Quality Monitoring Program. Region 4, SESD, Athens, Gerogia, EPA" (2002)
- "Ambient particulate matter and respiratory and cardiovascular illness in adults: particle-borne transition metals and the heart-lung axis", 4, pp.331~338 (1997)
- "Labile and bioaccessible fractions of heavy metals in the airborne particulate matter from urban and industrial area", 36, pp.3583~3590 (2002)
- "산업위생학개론", 서울, pp.115~126 (2000), 신광출판사
- "Appendix D - Particle size-selective sampling criteria for airborne particulate matter in annual reports of the committees on threshold limit value and biological exposure indices", pp.73~76 (2002), ACGIH
- "NIOSH manual of analytical Methods 4th ed Method No. 0500 and 7300" (1998), NIOSH
- "용접흄내 중금속분석시 전처리 방법 별 효율비교", 9, pp.135~144 (1999)
- "작업환경 측정 및 평가", pp.162~198 (2002), 신광출판사
- "Progress toward implementation of new aerosol industrial hygiene standards with special reference to the aluminium industry", 163, pp.3~9 (1995)
- "Investigation into the Impact of Introducing Workplace Aerosol Standards Based on the Inhalable Fraction", 121, pp.1207~1214 (1996)
- "Field Comparison of 37 mm Closed-Face Cassettes and IOM Samplers", 17(3), pp.200~208 (2002)
- "Fine particles and human health-a review of epidemiological studies", 149, pp.235~242 (2004)
- "서울시 지하 철역내 분진 오염원의 정량적 기여도의 결정", 16 3, pp.309~319 (1994)
- "서울시 지하철 환경개선 방안 연구", pp.122~192 (1998), 서울특별시 지하철공사
- "서울시 지하 철역의 분진의 농도분포 및 화학적 조성에 관한 연 구 대한환경공학회 춘계학술연구발표회 논문초록집", pp.53~55 (1993)
- "지하철분진 무기원소 분석을 통한 분진 발생 원 양적 기여도 추정" (1998)