본문 바로가기
KERD
논문

수용액중 극미량 니켈(Ⅱ)과 아연(Ⅱ)의 흡착농축 및 ICP-AES정량에관한 연구

Adsorptive Preconcentration and ICP-AES Determination forTrace Amount of Ni(ll) and Zn(ll) in Aqueous Solution

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

A determination method of trace Ni(II) and Zn(II) in aqueous solution was studied and developed by adsorbing on titanium dioxide. For this purpose, several conditions were optimized such as the pH of sample solution, adsorption time, the types and concentration acid, and desorption time. The titanium dioxide was added in sample solution which was pH adjusted. Then, the sample solution was stirred for 5 minutes. This mixture was stored in room temperature for 30 minutes to allow adsorption. After filtering and washing the titanium dioxide, the analytes were dissolved from the titanium dioxide on membrane filter by an ultrasonic vibration for 10 minutes in 1.0 M HNO3 solution. Then, this sample solution was analysed using ICP-AES. The adsorption equilibrium was achieved in 30 minutes. The desorption was the most of effective with 1.0 M(mol/l) nitric acid solution, and desorption time was 10 minutes. This procedure was applied for the analysis of two real samples, i.e., brown seaweed and tangle. The recoveries of Ni(II) and Zn(II) in spiked samples were 89.4~98.9% for analytes.

Abstract

A determination method of trace Ni(II) and Zn(II) in aqueous solution was studied and developed by adsorbing on titanium dioxide. For this purpose, several conditions were optimized such as the pH of sample solution, adsorption time, the types and concentration acid, and desorption time. The titanium dioxide was added in sample solution which was pH adjusted. Then, the sample solution was stirred for 5 minutes. This mixture was stored in room temperature for 30 minutes to allow adsorption. After filtering and washing the titanium dioxide, the analytes were dissolved from the titanium dioxide on membrane filter by an ultrasonic vibration for 10 minutes in 1.0 M HNO3 solution. Then, this sample solution was analysed using ICP-AES. The adsorption equilibrium was achieved in 30 minutes. The desorption was the most of effective with 1.0 M(mol/l) nitric acid solution, and desorption time was 10 minutes. This procedure was applied for the analysis of two real samples, i.e., brown seaweed and tangle. The recoveries of Ni(II) and Zn(II) in spiked samples were 89.4~98.9% for analytes.

참고문헌 (10)

  1. "Preconcentration and determination of trace cobalt and nickel by the adsorption of Metal-PDC complexes on the anion-exchange resin suspension", 13(5), pp.608~615 (2000)
  2. "Photocatalytic oxidation of Cadimum-EDTA with titanium dioxide", 33
  3. "Adsorption of Cr onto TiO2 from dilute aqueous solution", 35(7), pp.55~62 (1997)
  4. "Adsorption characteristics of As(III) and As(V) with titanium dioxide loaded amberite XAD-7 resin.", 18, pp.1345~1349 (2002)
  5. "Simultaneous adsorption of sodium dodecyl sulfate and poly on titanium dioxide with quaternary ammonium groups", 155, pp.413~417 (1999)
  6. "Adsorption of metal ion and aromatic compounds by anionic surfactant-coated particles of titanium dioxide", 144, pp.210~206 (1998)
  7. "Investigation of the electrical double layer in a metal oxide", monovalent electrolyte solution system, 1997, pp.187, 381~387
  8. "Adsorption of Au atoms on stoichiometric and reduced TiO2", 542, pp.72~80 (2003), a first principles study
  9. "Surface charge properties of colloidal titanium dioxide in ethylene glycol and water", 203, pp.229~236 (2002), and Vincent
  10. "Hwahak Konghak", (1), pp.~42 (2000)

관련 논문AI추천

이 간행물의 다른 논문 (13건)