본문 바로가기
KERD
논문

인천지역 일부 학교의 실내 및 대기 중 포름알데히드 농도 평가

Assessment of Formaldehyde Concentration in Indoor and Outdoor Environments of Schools in Incheon

2

조회

0

다운로드

10

인용

0

참고문헌

초록

Abstract

This study evaluated formaldehyde concentration in classrooms and on roofs at 4 elementary schools, 3 middle schools and 3 high schools in Incheon City. These schools were chosen based on their surrounding environments that included industrial site, landfill, railway, 8-lane road and harbor. Indoor concentration ranged between 4.65 and 56.25mg/m3, while that of outdoor concentration was 1.23~10.22mg/m3, both of which were below 100mg/m3, a formaldehyde criterion stipulated by the School Health Act. Indoor concentration was higher than outdoor concentration by 1.4~5.9 times, and there was a positive correlation between indoor and outdoor formaldehyde concentrations (R=0.49). As for indoor concentration, multi-use practice rooms had an average 2.8 times higher than that of usual classrooms with a statistically significant difference (p<0.01). Indoor formaldehyde concentration had a positive correlation with the construction year (R=0.55). The school close to the industrial complex had the highest ambient formaldehyde concentration, followed by the one near a landfill. The formaldehyde concentration in school in the vicinity of the industrial complex was twice or more than that of the school located other site. In conclusion, this study suggests that it is crucial to consider surrounding environments in selecting school sites, as it can influence ambient air contamination, as well as using construction material that emit less formaldehyde, in order to protect the health of students, teachers and school staff.

참고문헌 (16)

  1. Levy, "Impact of residential nitrogen dioxide exposure on personal exposure: an international study", 48, pp.553~60 (1998)
  2. EPA, "Indoor air quality(IAQ) tool for school, IAQ coordinator′s guide" (2000), EPA
  3. NRC, "Formaldehyde and other aldehydes. National Academy Press, National Research Council, National" (1981), NRC
  4. International Agency for Research on Cancer(IARC), "IARC monographs Vol. 88 formaldehyde, 2-butoxyethanol" (2005), IARC, Lyon, France
  5. 노동부, "화학물질 및 물리적인자의 노출기준" (2007), 노동부
  6. 교육인적자원부, "학교보건법 시행규칙 제3조 별표 4 의 2. 교사안에서의 실내공기질 유지·관리기준" (2007), 교육인적자원부
  7. WHO, "Air quality guidelines" (2001), WHO
  8. Lee, "Inter-comparison of air pollutant concentrations in different indoor environments in Hong Kong", 36, pp.1929~1940 (2002)
  9. 김윤신, "실내외 포름알데히드 농도에 관한 조 사연구", pp.1~9 (1989)
  10. 하권철, "경남지역 지하생활공간 중 미량 유해물질인 포름알데히드의 농도 분포 특성", 30(5), pp.353~357 (2004)
  11. 윤충식, "유아교육시 설의 위치 및 실내 · 실외에 따른 포름알데히드 농도 변화", 30(3), pp.259~263 (2004)
  12. 환경부, "실내공기질관리 업무편람 2004" (2004), 환경부
  13. National Institute for Occupational Safety & Health (NIOSH), "NIOSH manual of analytical methods", pp.2003~154 (2003), National Institute for Occupational Safety & Health (NIOSH)
  14. Matthews, "Surface emission monitoring of pressed-wood products containing urea-formaldehyde resins", pp.1 301~4 309 (1986)
  15. 심상효, "신축공동주택의 실내공기질 특성 및 평가-휘발성 유기화합물 및 포름알데히드 중심으로", 32(4), pp.275~281 (2006)
  16. 환경부, "다중이용시설등의 실내공기질 관리법 시행 규칙 제3조 별표 2. 실내공기질유지기준" (2006), 환경부

관련 논문AI추천

이 간행물의 다른 논문 (18건)