2

조회

0

다운로드

7

인용

0

참고문헌

키워드

초록

We investigated a trait of odor and the relationship between odor unit and odorous compounds using multiple regression analysis based on data compiled from Sihwa (SIC), Banwol (BIC), Banwol plating (BPIC) and Poseung industrial complex (PIC). These areas are odor control areas in Gyeonggi province. It was revealed that NH3 and styrene concentrations in SIC and BPIC were relatively higher and H2S concentration especially in BIC was more than five times higher than other areas. As a result of regression analysis using SAS, intensity of odor unit was highly related to concentrations of H2S, TMA, styrene and n-valeraldehyde in SIC, H2S, acetaldehyde, and butyraldehyde in BPIC and NH3 in BIC.

Abstract

We investigated a trait of odor and the relationship between odor unit and odorous compounds using multiple regression analysis based on data compiled from Sihwa (SIC), Banwol (BIC), Banwol plating (BPIC) and Poseung industrial complex (PIC). These areas are odor control areas in Gyeonggi province. It was revealed that NH3 and styrene concentrations in SIC and BPIC were relatively higher and H2S concentration especially in BIC was more than five times higher than other areas. As a result of regression analysis using SAS, intensity of odor unit was highly related to concentrations of H2S, TMA, styrene and n-valeraldehyde in SIC, H2S, acetaldehyde, and butyraldehyde in BPIC and NH3 in BIC.

참고문헌 (13)

  1. The ministry of environment (Korea), "A handbook of odor control", 2~3 (2007)
  2. The ministry of environment (Korea), "The method of odor examination", ~ (2007)
  3. 김종보, "반월?시화공단 주변 주거지역의 악취현황 및황화합물의 체감도", 한국대기환경학회지, 23(2), pp.147~157 (2007), 한국대기환경학회
  4. Koe, L. C. C., "Hydrogensulphide odor in sewage atmospheres", Water Air Soil Pollution, 24, pp.2997~306 (1985)
  5. Gostelow, P, "Sewage treatment works odour measurement", Water Science and Technology, 41(6), pp.33~40 (2000)
  6. Kim, S. T, "A fundamental study of SOQ, odor unit and odor intensity interrelations for odor phenomenon evaluation", Proceeding of the 39th Meeting of KOSAE, pp.290~291 (2005)
  7. 김만구, "관능법과 기기분석법을 접목한 악취원인물질 평가방법", 한국냄새환경학회지, 1(1), pp.31~38 (2002), 한국냄새환경학회
  8. Kim, S. T, "An analysis between odor concentration quotient and odor concentration unit", Proceeding of the 38th Meeting of KOSAE, pp.270~271 (2004)
  9. Kim, J. B, "A study on the relatinship between odor unit and odorous compounds in the industrial complex", Proceeding of the 46th Meeting of KOSAE, pp.471~472 (2008)
  10. Kim,J.B, "A study on the relationshipX between odor unit and odorous compounds in industrial complex", Proceeding of the Korean Environmental Sciences Society Conference, pp.134~137 (2008)
  11. Heo, M. H., "SAS regression analysis" (2001), Free Academy Inc.
  12. Kang, H. C, "An introduction of SAS data analysis" (2005), Free Academy Inc.
  13. Drew, G. H., "Appropriateness of selecting different averaging times for modelling chronic and acute exposure to environmental odours", Atmospheric Environment, 41, pp.2870~2880 (2007)

이 간행물의 다른 논문 (12건)