본문 바로가기
KERD
논문KCI 등재

Implantable Bladder Sensors: A Methodological Review

2

조회

0

다운로드

4

인용

0

참고문헌

키워드

초록

The loss of urinary bladder control/sensation, also known as urinary incontinence (UI), is a common clinical problem in autistic children, diabetics, and the elderly. UI not only causes discomfort for patients but may also lead to kidney failure, infections, and even death. The increase of bladder urine volume/pressure above normal ranges without sensation of UI patients necessitates the need for bladder sensors. Currently, a catheter-based sensor is introduced directly through the urethra into the bladder to measure pressure variations. Unfortunately, this method is inaccurate because measurement is affected by disturbances in catheter lines as well as delays in response time owing to the inertia of urine inside the bladder. Moreover, this technique can cause infection during prolonged use; hence, it is only suitable for short-term measurement. Development of discrete wireless implantable sensors to measure bladder volume/pressure would allow for long-term monitoring within the bladder, while maintaining the patient’s quality of life. With the recent advances in microfabrication, the size of implantable bladder sensors has been significantly reduced. However, microfabricated sensors face hostility from the bladder environment and require surgical intervention for implantation inside the bladder. Here, we explore the various types of implantable bladder sensors and current efforts to solve issues like hermeticity, biocompatibility, drift, telemetry, power, and compatibility issues with popular imaging tools such as computed tomography and magnetic resonance imaging. We also discuss some possible improvements/emerging trends in the design of an implantable bladder sensor.

Abstract

The loss of urinary bladder control/sensation, also known as urinary incontinence (UI), is a common clinical problem in autistic children, diabetics, and the elderly. UI not only causes discomfort for patients but may also lead to kidney failure, infections, and even death. The increase of bladder urine volume/pressure above normal ranges without sensation of UI patients necessitates the need for bladder sensors. Currently, a catheter-based sensor is introduced directly through the urethra into the bladder to measure pressure variations. Unfortunately, this method is inaccurate because measurement is affected by disturbances in catheter lines as well as delays in response time owing to the inertia of urine inside the bladder. Moreover, this technique can cause infection during prolonged use; hence, it is only suitable for short-term measurement. Development of discrete wireless implantable sensors to measure bladder volume/pressure would allow for long-term monitoring within the bladder, while maintaining the patient’s quality of life. With the recent advances in microfabrication, the size of implantable bladder sensors has been significantly reduced. However, microfabricated sensors face hostility from the bladder environment and require surgical intervention for implantation inside the bladder. Here, we explore the various types of implantable bladder sensors and current efforts to solve issues like hermeticity, biocompatibility, drift, telemetry, power, and compatibility issues with popular imaging tools such as computed tomography and magnetic resonance imaging. We also discuss some possible improvements/emerging trends in the design of an implantable bladder sensor.

참고문헌 (61)

  1. Coyne KS, "Economic burden of urgency urinary incontinence in the United States: a systematic review", J Manag Care Pharm, 20, pp.130~140 (2014)
  2. Ramesh MV, "Design of wireless real time artificial sphincter control system for urinary incontinence", 2014 International Symposium on Technology Management and Emerging Technologies (ISTMET 2014) (2014), IEEE;
  3. Yu L, "Chronically implanted pressure sensors: challenges and state of the field", Sensors (Basel), 14, pp.20620~20644 (2014)
  4. Mendez A, "Estimation of bladder volume from afferent neural activity", IEEE Trans Neural Syst Rehabil Eng, 21, pp.704~715 (2013)
  5. Waltz FM, "Bladder volume sensing by resistance measurement", IEEE Trans Biomed Eng, 18, pp.42~46 (1971)
  6. Dreher RD, "Bladder volume sensing by local distension measurement", IEEE Trans Biomed Eng, 19, pp.247~248 (1972)
  7. Rise MT, "An ultrasonic bladder-volume sensor", IEEE Trans Biomed Eng, 26, pp.709~711 (1979)
  8. Holmes J, "Hydrodynamics of mictwition" (1971), Thomas
  9. West KA, "Sonocystography: a method for measuring residual urine", Scan J Urol Nephrol, 1, pp.68~70 (1967)
  10. Doust BD, "Determination of organ volume by means of ultrasonic B-mode scanning", J Clin Ultrasound, 2, pp.127~130 (1974)
  11. Pedersen JF, "Residual urine determination by ultrasonic scanning", Am J Roentgenol Radium Ther Nucl Med, 125, pp.474~478 (1975)
  12. McLean GK, "Determination of bladder volumes by gray scale ultrasonography", Radiology, 128, pp.181~182 (1978)
  13. Ulrich WD, "Ultrasound dosage for nontherapeutic use on human beings: extrapolations from a literature survey", IEEE Trans Biomed Eng, 21, pp.48~51 (1974)
  14. Rajagopalan S, "A polypyrrole-based strain sensor dedicated to measure bladder volume in patients with urinary dysfunction", Sensors, 8, pp.5081~5095 (2008)
  15. Gutierrez CA, "Low-cost carbon thick-film strain sensors for implantable applications", J Micromech Microeng, 20, pp.095028~ (2010)
  16. Hung C, "A wireless bladder volume monitoring system using a flexible capacitance- based sensor", 2013 IEEE topical conference on biomedical wireless technologies, networks, and sensing systems (BioWireless) (2013), IEEE
  17. Williams DF, "Corrosion of implant materials", Ann Rev Mater Sci, 6, pp.237~266 (1976)
  18. Yuen T, "Neural prostheses: fundamental studies", pp.171~321 (1990), Prentice Hall
  19. Kotzar G, "Evaluation of MEMS materials of construction for implantable medical devices", Biomaterials, 23, pp.2737~2750 (2002)
  20. Jiang G, "Design challenges of implantable pressure monitoring system", Front Neurosci, 4, pp.29~ (2010)
  21. 정연호, "Development of Implantable Medical Devices: From an Engineering Perspective", International Neurourology Journal, 17(3), pp.98~106 (2013), 대한배뇨장애요실금학회[DOI]
  22. Rogers T, "Selection of glass, anodic bonding conditions and material compatibility for silicon-glass capacitive sensors", Sens Actuator A, 46, pp.113~120 (1995)
  23. Harz M, "Curvature changing or flatening of anodically bonded silicon and borosilicate glass", Sens Actuator A, 55, pp.201~209 (1996)
  24. Zhou D, "Accelerated corrosion tests on Silicon wafers for implantable medical devices", Proceedings of 198th Electrochemical Society Meeting (2000), Electrochemical Society
  25. Akyildiz IF, "Sankarasubramaniam Y, Cayirci E. Wireless sensor networks: a survey", Computer Netw, 38, pp.393~422 (2002)
  26. Budinger TF, "Biomonitoring with wireless communications", Annu Rev Biomed Eng, 5, pp.383~412 (2003)
  27. Poon AS, "Optimal frequency for wireless power transmission into dispersive tissue", IEEE Trans Antenna Propag, 58, pp.1739~1750 (2010)
  28. DeHennis AD, "Remotely-powered wireless monitoring systems", Ph.D, pp.2004
  29. Yu H, "A wireless microsystem for multichannel neural recording microprobes", Ph.D, pp.2004
  30. Abouei J, "Energy efficiency and reliability in wireless biomedical implant systems", IEEE Trans Inf Technol Biomed, 15, pp.456~466 (2011)
  31. Puers R, "Linking sensors with telemetry: impact on the system design", Sens Actuator A, 52, pp.169~174 (1996)
  32. Suster M, "Wireless recharging of battery over large distance for implantable bladder pressure chronic monitoring", Proceedings of the 16th International on Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS) (2011), IEEE
  33. Chow EY, "Fully wireless implantable cardiovascular pressure monitor integrated with a medical stent", IEEE Trans. Biomed. Eng, 57, pp.1487~1496 (2010)
  34. Kim J, "Fabrication and evaluation of implantable pressure sensor using strain gauge", Proceedings of the Biomedical Engineering International Conference (BMEiCON) (2012), IEEE
  35. Fonseca MA, "Flexible wireless passive pressure sensors for biomedical applications", Proceedings of the Solid-State Sensor, Actuator, and Microsystems Workshop (2006), Wireless Integrated MicroSensing & Systems
  36. Cong P, "Wireless batteryless implantable blood pressure monitoring microsystem for small laboratory animals", IEEE Sens J, 10, pp.243~254 (2010)
  37. Majerus SJ, "Low-power wireless micromanometer system for acute and chronic bladderpressure monitoring", IEEE Trans Biomed Eng, 58, pp.763~767 (2011)
  38. Axisa F, "Design and fabrication of a low cost implantable bladder pressure monitor", Conf Proc IEEE Eng Med Biol Soc, pp.4864~4867 (2009)
  39. Chen PJ, "Microfabricated implantable Parylene-based wireless passive intraocular pressure sensors", J Microelectromec Syst, 17, pp.1342~1351 (2008)
  40. Siwapornsathain E, "A telemetry and sensor platform for ambulatory urodynamics", Proceedings of the Biology 2nd Annual International IEEE-EMB Special Topic Conference on Microtechnologies in Medicine, pp.283~287 (2002)
  41. Takahata K, "A wireless microsensor for monitoring flow and pressure in a blood vessel utilizing a dual-inductor antenna stent and two pressure sensors", Proceedings of the 17th IEEE International Conference on Micro ElectroMechanical Systems (2004), IEEE
  42. Chen PJ, "Implantable micromechanical parylene-based pressure sensors for unpowered intraocular pressure sensing", J Micromech Microeng, 17, pp.1931~1938 (2007)
  43. Aquilina K, "Preliminary evaluation of a novel intraparenchymal capacitive intracranial pressure monitor laboratory investigation", J Neurosurg, 115, pp.561~569 (2011)
  44. Fan Z, "Parylene surface-micromachined membranes for sensor applications", J Microelectromec Syst, 13, pp.484~490 (2004)
  45. Jourand P, "The BladderPill: an in-body system logging bladder pressure", Sens Actuator A, 162, pp.160~166 (2010)
  46. Schnakenberg U, "Intravascular pressure monitoring system", Sens Actuator A, 110, pp.61~67 (2004)
  47. Gutierrez C, "A subnanowatt microbubble pressure sensor based on electrochemical impedance transduction in a flexible allparylene", parylene package, 2011, ~[DOI]
  48. Cleven NJ, "A novel fully implantable wireless sensor system for monitoring hypertension patients", IEEE Trans Biomed Eng, 59, pp.3124~3130 (2012)
  49. Hierold C, "Implantable low power integrated pressure sensor system for minimal invasive telemetric patient monitoring", Proceedings of the the 11th Annual International Workshop on Micro Electro Mechanical Systems (1998), IEEE
  50. Tan R, "Development of a fully implantable wireless pressure monitoring system", Biomed Microdevices, 11, pp.259~264 (2009)
  51. Koley G, "Miniaturized implantable pressure and oxygen sensors based on polydimethylsiloxane thin films", Mater Sci Eng R Rep, 29, pp.685~690 (2009)
  52. Majerus SJ, "Wireless, ultra-low-power implantable sensor for chronic bladder pressure monitoring", ACM J Emerg Technol Comput Syst, 8(11) (2012)
  53. Liang B, "A novel implantable saw sensor for blood pressure monitoring", Proceedings of the 16th International on Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS) (2011), IEEE
  54. Chua-Chin Wang, "A Mini-Invasive Long-Term Bladder Urine Pressure Measurement ASIC and System", IEEE Trans Biomed Circuits Syst, 2, pp.44~49 (2008)
  55. Li C, "Dual-mode operation of flexible piezoelectric polymer diaphragm for intracranial pressure measurement", Appl Phys Lett, 96, pp.053502~ (2010)
  56. Bott TR, "Biofouling control with ultrasound", Heat Transf Eng, 21, pp.43~49 (2000)
  57. Frischholz M, "Telemetric implantable pressure sensor for shortand long-term monitoring of intracranial pressure", Conf Proc IEEE Eng Med Biol Soc, pp.514~ (2007)
  58. Fletter PC, "Wireless micromanometer system for chronic bladder pressure monitoring", Proceedings of the 2009 Sixth International Conference on Networked Sensing Systems (INSS) (2009), IEEE
  59. Kilinc EG, "Remotely powered implantable heart monitoring system for freely moving animals", Proceedings of the 2013 5th IEEE International Workshop on Advances in Sensors and Interfaces (IWASI) (2013), IEEE
  60. Coosemans J, "An autonomous bladder pressure monitoring system", Sens Actuator A, 123, pp.155~161 (2005)
  61. Kim A, "An implantable pressure sensing system with electromechanical interrogation scheme", IEEE Trans Biomed Eng, 61, pp.2209~2217 (2014)

이 간행물의 다른 논문 (13건)