Neuromodulation was introduced for patients with poor outcomes from the existing traditional treatment approaches. It is well-established as an alternative, novel treatment option for voiding dysfunction. The current system of neuromodulation uses an open-loop system that only delivers continuous stimulation without considering the patient’s state changes. Though the conventional open-loop system has shown positive clinical results, it can cause problems such as decreased efficacy over time due to neural habituation, higher risk of tissue damage, and lower battery life. Therefore, there is a need for a closed-loop system to overcome the disadvantages of existing systems. The closed-loop neuromodulation includes a system to monitor and stimulate micturition reflex pathways from the lower urinary tract, as well as the central nervous system. In this paper, we reviewed the current technological status to measure biomarker for closed-loop neuromodulation systems for voiding dysfunction.

Abstract

Neuromodulation was introduced for patients with poor outcomes from the existing traditional treatment approaches. It is well-established as an alternative, novel treatment option for voiding dysfunction. The current system of neuromodulation uses an open-loop system that only delivers continuous stimulation without considering the patient’s state changes. Though the conventional open-loop system has shown positive clinical results, it can cause problems such as decreased efficacy over time due to neural habituation, higher risk of tissue damage, and lower battery life. Therefore, there is a need for a closed-loop system to overcome the disadvantages of existing systems. The closed-loop neuromodulation includes a system to monitor and stimulate micturition reflex pathways from the lower urinary tract, as well as the central nervous system. In this paper, we reviewed the current technological status to measure biomarker for closed-loop neuromodulation systems for voiding dysfunction.

참고문헌 (62)

  1. Chu CM, "The impact of treatment of overactive bladder on physical activity limitations", J Womens Health (Larchmt), 25, pp.801~805 (2016)
  2. Po-Fan Hsieh, "Botulinum toxin A for the Treatment of Overactive Bladder", Toxins, 8(3), pp.59~ (2016), MDPI AG[DOI]
  3. 장현종, "Central Regulation of Micturition and Its Association With Epilepsy", International Neurourology Journal, 22(1), pp.2~8 (2018), 대한배뇨장애요실금학회
  4. Wolz-Beck M, "Physiotherapy and behavior therapy for the treatment of overactive bladder syndrome: a prospective cohort study", Arch Gynecol Obstet, 295, pp.1211~1217 (2017)
  5. Karl-Erik Andersson, "Current Pharmacologic Approaches in Painful Bladder Research: An Update", International Neurourology Journal, 21(4), pp.235~242 (2017), 대한배뇨장애요실금학회
  6. Ladi-Seyedian SS, "Pharmacological treatments available for the management of underactive bladder in neurological conditions", Expert Rev Clin Pharmacol, 11, pp.193~204 (2018)
  7. Abello A, "Electrical neuromodulation in the management of lower urinary tract dysfunction: evidence, experience and future prospects", Ther Adv Urol, 10, pp.165~173 (2018)
  8. Toby C. Chai, "New therapeutic directions to treat underactive bladder", Investigative and Clinical Urology, 58, pp.99~106 (2017), 대한비뇨의학회[DOI]
  9. Lay AH, "The role of neuromodulation in patients with neurogenic overactive bladder", Curr Urol Rep, 13, pp.343~347 (2012)
  10. Sanford MT, "Neuromodulation in neurogenic bladder", Transl Androl Urol, 5, pp.117~126 (2016)
  11. Tanagho EA, "Neural stimulation for control of voiding dysfunction: a preliminary report in 22 patients with serious neuropathic voiding disorders", J Urol, 142(2 Pt 1), pp.340~345 (1989)
  12. Medtronic, Inc, "premarket approval of the Interstim Sacral Nerve Stimulation (SNS) System--FDA", Notice. Fed Regist, 63, pp.4457~ (1998)
  13. Chancellor MB, "Principles of sacral nerve stimulation (SNS) for the treatment of bladder and urethral sphincter dysfunctions", Neuromodulation, 3, pp.16~26 (2000)
  14. McGuire E, "Control of reflex detrusor activity in normal and spinal injured non-human primates", J Urol, 129, pp.197~199 (1983)
  15. Govier FE, "Percutaneous afferent neuromodulation for the refractory overactive bladder:results of a multicenter study", J Urol, 165, pp.1193~1198 (2001)
  16. Karam R, "Real-time, autonomous bladder event classification and closedloop control from single-channel pressure data", Conf Proc IEEE Eng Med Biol Soc, pp.5789~5792 (2016)
  17. 이지웅, "Emerging Neural Stimulation Technologies for Bladder Dysfunctions", International Neurourology Journal, 19(1), pp.3~11 (2015), 대한배뇨장애요실금학회
  18. Wenzel BJ, "Closed loop electrical control of urinary continence", J Urol, 175, pp.1559~1563 (2006)
  19. Sagawa K, "Closed-loop physiological control of the heart", Ann Biomed Eng, 8, pp.415~429 (1980)
  20. Paul V, "Closed loop control of rate adaptive pacing: clinical assessment of a system analyzing the ventricular depolarization gradient", Pacing Clin Electrophysiol, 12, pp.1896~1902 (1989)
  21. Lillehei CW, "Transitor pacemaker for treatment of complete atrioventricular dissociation", J Am Med Assoc, 172, pp.2006~2010 (1960)
  22. Sutton R, "History of electrical therapy for the heart", Eur Heart J Suppl, 9, pp.13~10 (2007)
  23. Rickards AF, "Relation between QT interval and heart rate. New design of physiologically adaptive cardiac pacemaker", Br Heart J, 45, pp.56~61 (1981)
  24. Miller JD, "The implantable cardioverter-defibrillator:an update", Trends Cardiovasc Med, 25, pp.606~611 (2015)
  25. Shirvalkar P, "Closed-loop deep brain stimulation for refractory chronic pain", Front Comput Neurosci, 12, pp.18~ (2018)
  26. Bina RW, "Closed loop deep brain stimulation for PTSD, addiction, and disorders of affective facial interpretation: review and discussion of potential biomarkers and stimulation paradigms", Front Neurosci, 12, pp.300~ (2018)
  27. Hoang KB, "Biomarkers and stimulation algorithms for adaptive brain stimulation", Front Neurosci, 11, pp.564~ (2017)
  28. Meidahl AC, "Adaptive deep brain stimulation for movement disorders:the long road to clinical therapy", Mov Disord, 32, pp.810~819 (2017)
  29. Johnson LA, "Closed-Loop deep brain stimulation effects on Parkinsonian motor symptoms in a non-human primate - Is beta enough?", Brain Stimul, 9, pp.892~896 (2016)
  30. Powell CR, "Conditional electrical stimulation in animal and human models for neurogenic bladder: working toward a neuroprosthesis", Curr Bladder Dysfunct Rep, 11, pp.379~385 (2016)
  31. van Balken MR, "The use of electrical devices for the treatment of bladder dysfunction: a review of methods", J Urol, 172, pp.846~851 (2004)
  32. Gaziev G, "Percutaneous tibial nerve stimulation (PTNS) efficacy in the treatment of lower urinary tract dysfunctions: a systematic review", BMC Urol, 13, pp.61~ (2013)
  33. Gobbi C, "Percutaneous posterior tibial nerve stimulation as an effective treatment of refractory lower urinary tract symptoms in patients with multiple sclerosis: preliminary data from a multicentre, prospective, open label trial", Mult Scler, 17, pp.1514~1519 (2011)
  34. de Wall LL, "Effectiveness of percutaneous tibial nerve stimulation in the treatment of overactive bladder syndrome", Res Rep Urol, 9, pp.145~157 (2017)
  35. Scaldazza CV, "Percutaneous tibial nerve stimulation versus electrical stimulation with pelvic floor muscle training for overactive bladder syndrome in women: results of a randomized controlled study", Int Braz J Urol, 43, pp.121~126 (2017)
  36. de Sèze M, "Transcutaneous posterior tibial nerve stimulation for treatment of the overactive bladder syndrome in multiple sclerosis:results of a multicenter prospective study", Neurourol Urodyn, 30, pp.306~311 (2011)
  37. Burton C, "Effectiveness of percutaneous posterior tibial nerve stimulation for overactive bladder: a systematic review and meta-analysis", Neurourol Urodyn, 31, pp.1206~1216 (2012)
  38. Peters KM, "Randomized trial of percutaneous tibial nerve stimulation versus Sham efficacy in the treatment of overactive bladder syndrome: results from the SUmiT trial", J Urol, 183, pp.1438~1443 (2010)
  39. Wenzel BJ, "Detection of neurogenic detrusor contractions from the activity of the external anal sphincter in cat and human", Neurourol Urodyn, 25, pp.140~147 (2006)
  40. Horvath EE, "Conditional and continuous electrical stimulation increase cystometric capacity in persons with spinal cord injury", Neurourol Urodyn, 29, pp.401~407 (2010)
  41. Mendez A, "Estimation of bladder volume from afferent neural activity", IEEE Trans Neural Syst Rehabil Eng, 21, pp.704~715 (2013)
  42. Wenzel BJ, "Detecting the onset of hyper-reflexive bladder contractions from the electrical activity of the pudendal nerve", IEEE Trans Neural Syst Rehabil Eng, 13, pp.428~435 (2005)
  43. Macnab AJ, "The evolution of near infrared spectroscopy in urology", Biomed Spectrosc Imaging, 3, pp.311~344 (2014)
  44. Macnab A, "Validation of transcutaneous NIRS monitoring of bladder hemodynamics and oxygenation using a rabbit model", Biomed Spectrosc Imaging, 2, pp.91~99 (2013)
  45. Macnab A, "Bladder anatomy physiology and pathophysiology: elements that suit near infrared spectroscopic evaluation of voiding dysfunction", Biomed Spectrosc Imaging, 1, pp.223~235 (2012)
  46. Macnab AJ, "Wireless near-infrared spectroscopy (NIRS) of the bladder detrusor during uroflow in ambulant children and adults", J Urology, 181(4 Suppl), pp.600~601 (2009)
  47. Macnab AJ, "Ambulant monitoring of bladder oxygenation and hemodynamics using wireless near-infrared spectroscopy", Can Urol Assoc J, 7, pp.E98~E104 (2013)
  48. Macnab A, "Near-infrared spectroscopy of the bladder: new parameters for evaluating voiding dysfunction", Int J Spectrosc, pp.814179~ (2011)
  49. Fong D, "Non-invasive bladder volume sensing for neurogenic bladder dysfunction management", 2018 IEEE 15th International Conference Wearable and Implantable Body Sensor Networks (BSN), pp.82~85 (2018), Institute of Electrical and Electronics Engineers
  50. Molavi B, "Noninvasive optical monitoring of bladder filling to capacity using a wireless near infrared spectroscopy device", IEEE Trans Biomed Circuits Syst, 8, pp.325~333 (2014)
  51. Ingelin Clausen, "Measurement of Urinary Bladder Pressure: A Comparison of Methods", Sensors, 18(7), pp.2128~ (2018), MDPI AG[DOI]
  52. Mathias Naangmenkpeong Dakurah, "Implantable Bladder Sensors: A Methodological Review", International Neurourology Journal, 19(3), pp.133~141 (2015), 대한배뇨장애요실금학회
  53. Opisso E, "Urethral sphincter EMG-controlled dorsal penile", clitoral nerve stimulation to treat neurogenic detrusor overactivity, 2011, pp.8, 036001~
  54. Bruns TM, "Multielectrode array recordings of bladder and perineal primary afferent activity from the sacral dorsal root ganglia", J Neural Eng, 8, pp.056010~ (2011)
  55. Majerus SJ, "Suburothelial bladder contraction detection with implanted pressure sensor", PLoS One, 12, pp.e0168375~ (2017)
  56. Rutter EM, "Detection of bladder contractions from the activity of the external urethral sphincter in rats using sparse regression", IEEE Trans Neural Syst Rehabil Eng, 26, pp.1636~1644 (2018)
  57. Ross SE, "Evaluation of decoding algorithms for estimating bladder pressure from dorsal root ganglia neural recordings", Ann Biomed Eng, 46, pp.233~246 (2018)
  58. Brindley GS, "Electrolytic current-control elements for surgically implanted electrical devices", Med Biol Eng Comput, 24, pp.439~441 (1986)
  59. Kim A, "An Universal packaging technique for low-drift implantable pressure sensors", Biomed Microdevices, 18, pp.32~ (2016)
  60. Young DJ, "Implantable wireless battery recharging system for bladder pressure chronic monitoring", Lab Chip, 15, pp.4338~4347 (2015)
  61. Khurram A, "Chronic monitoring of lower urinary tract activity via a sacral dorsal root ganglia interface", J Neural Eng, 14, pp.036027~ (2017)
  62. Kim MK, "Implantable bladder volume sensor based on resistor ladder network composed of conductive hydrogel composite", Conf Proc IEEE Eng Med Biol Soc, pp.1732~1735 (2017)

이 간행물의 다른 논문 (12건)