본문 바로가기
KERD
논문KCI 등재

인공호흡기 회로 교환주기가 인공호흡기 관련 폐렴에 미치는 영향에 관한 메타 분석

A Meta-Analysis of the Ventilator Circuit Change Period on Ventilator-Associated Pneumonia

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류간호학

초록

Purpose: This meta-analysis was aimed to investigate the evidence of proper period of the ventilator circuit change using existing research. Methods: For this study, 14 published studies between 1995 and 2010 were tested by Macaskill,Funnel Plot, the Odds Ratio of DerSimonian and Laird, Fisher and Liptak analysis. Results: There were no publication bias found in the subjects. The results of the meta-analysis demonstrated no statistically significant differences were observed in neither the Odds Ratio (OR=1.18, 95% CI=0.94-1.47) of the frequency of ventilator-associated pneumonia and the mortality based on the period of the ventilator circuit change (Fisher p=.332, Liptak p=.498), nor the ventilation duration of ventilator (Fisher p=.843, Liptak p=.506), and the hospital length of stay (Fisher p=.254, Liptak p=.480). Conclusion: In order to present more concrete guidelines on the period of the ventilator circuit change, further research is warranted to thoroughly control confounding variables which related to the periods of the ventilator circuit change.

Abstract

Purpose: This meta-analysis was aimed to investigate the evidence of proper period of the ventilator circuit change using existing research. Methods: For this study, 14 published studies between 1995 and 2010 were tested by Macaskill,Funnel Plot, the Odds Ratio of DerSimonian and Laird, Fisher and Liptak analysis. Results: There were no publication bias found in the subjects. The results of the meta-analysis demonstrated no statistically significant differences were observed in neither the Odds Ratio (OR=1.18, 95% CI=0.94-1.47) of the frequency of ventilator-associated pneumonia and the mortality based on the period of the ventilator circuit change (Fisher p=.332, Liptak p=.498), nor the ventilation duration of ventilator (Fisher p=.843, Liptak p=.506), and the hospital length of stay (Fisher p=.254, Liptak p=.480). Conclusion: In order to present more concrete guidelines on the period of the ventilator circuit change, further research is warranted to thoroughly control confounding variables which related to the periods of the ventilator circuit change.

참고문헌 (31)

  1. 대한병원감염관리학회, "병원감염관리" (2006), 한미의학
  2. 이상오, "전국병원감염감시체계 중환자실 부문 결과 보고: 2007년 7월에서 2008년 6월까지의 자료 정리", 병원감염관리, 13(2), pp.69~82 (2008)
  3. 이진희, "인공호흡기 관련 폐렴 발생률과 위험요인: 일개병원 중환자실을 대상으로", 석사, pp.2008
  4. 장선영, "중환자실의 호흡기관련 폐렴(Ventilatorassociated pneumonia, VAP) 발생과 재원일수 및 진료비 분석", 석사, pp.2001
  5. Alexiou, V. G, "Impact of patient position on the incidence of ventilator-associated pneumonia: A meta-analysis of randomized controlled trials", Journal of Critical Care, 24(4), pp.515~522 (2009)
  6. Chastre, J, "Ventilator-associated pneumonia", American Journal of Respiratory and Critical Care Medicine, 165(7), pp.867~903 (2002)
  7. Dezfulian, C, "Subglottic secretion drainage for preventing ventilatorassociated pneumonia: A meta-analysis", The American Journal of Medicine, 118(1), pp.11~18 (2005)
  8. Dixon, C, "Ventilator-associated pneumonia and ventilator circuit changes: A comparison of 2-day versus 7-day circuit changes", The Canadian Journal of Infection Control, 13(2), pp.51~54 (1998)
  9. Fink, J. B, "Extending ventilator circuit change interval beyond 2 days reduces the likelihood of ventilator-associated pneumonia", Chest, 113(2), pp.405~411 (1998)
  10. Garcia, R, "Reducing ventilator-associated pneumonia through advanced oral-dental care: A 48-month study", American Journal of Critical Care, 18(6), pp.523~532 (2009)
  11. Haley, R. W, "The efficacy of infection surveillance and control programs in preventing nosocomial infections in US hospitals", American Journal of Epidemiology, 121(2), pp.182~205 (1985)
  12. Han, J. N, "Effects of decreasing the frequency of ventilator circuit changes to every 7 days on the rate of ventilator-associated pneumonia in a Beijing Hospital", Respiratory Care, 46(9), pp.891~896 (2001)
  13. Hess, D, "Weekly ventilator circuit changes: A strategy to reduce costs without affecting pneumonia rates", Anesthesiology, 82(4), pp.903~911 (1995)
  14. 김남초, "인공호흡기 튜브교환주기에 따른 인공호흡기 관련 폐렴발생률", 성인간호학회지, 15(3), pp.463~471 (2003), 성인간호학회
  15. Kollef,M.H, "Ventilator associated pneumonia. A multivariate analysis", The Journal of the American Medical Association, 270(16), pp.1965~1970 (1993)
  16. Kollef, M. H, "Mechanical Ventilation with or without 7-day circuit changes", A randomized controlled trial. Annals of Internal Medicine, 123(3), pp.168~174 (1995)
  17. Kotilainen, H. R, "Cost analysis and clinical impact of weekly ventilator circuit changes in patients in intensive care unit", American Journal of Infection Control, 25(2), pp.117~120 (1997)
  18. Lien, T. C, "Ventilatorassociated pneumonia with circuit changes every 2 days versus every week", Chinese Medical Journal, 64(3), pp.161~167 (2001)
  19. Long, M. N, "Prospective, randomized study of ventilator-associated pneumonia in patients with one versus three ventilator circuit changes per week", Infection Control and Hospital Epidemiology, 17(1), pp.14~19 (1996)
  20. Lorente, L, "Periodically changing ventilator circuits is not necessary to prevent ventilator-associated pneumonia when a heat and moisture exchanger is used", Infection Control and hospital Epidemiology, 25(12), pp.1077~1082 (2004)
  21. Makhoul, I. R, "Frequency of change of ventilator circuit in premature infants: Impact on ventilator-associated pneumonia", Pediatric Critical Care Medicine, 2(2), pp.127~132 (2001)
  22. Oh, H. S, "A prospective study on the incidence of ventilator-associated pneumonia in patients with circuit changes every 3days versus weekly changes", Korean Journal of Nosocomial infection Control, 5(1), pp.9~21 (2000)
  23. Powers,J.M, "Factors related to the development of ventilator-associated pneumonia in the neuroscience patient population", doctor, pp.2007
  24. Rello, J, "Associations between empirical antimicrobial therapy at the hospital and mortality in patients with severe community-acquired pneumonia", Intensive Care Medicine, 28(8), pp.1030~1035 (2002)
  25. Samransamruajkit, R, "Effect of frequency of ventilator circuit changes (3 vs 7days) on the rate of ventilator-associated pneumonia in PICU", Journal of Siempos (2009)
  26. I. I, "Closed tracheal suction systems for prevention of ventilator-associated pneumonia.British Journal of", Anaesthesia, 100(3), pp.299~306 (2008)
  27. Tablan, D. C, "Guidelines for preventing health-care-associated pneumonia, 2003: Recommendations of CDC and the healthcare infection control practices advisory committee", MMWR, 53(RR03), pp.1~36 (2004)
  28. Tantipong, H, "Randomized controlled trial and meta-analysis of oral decontamination with 2% chlorhexidine solution for the prevention of ventilator-associated pneumonia", Infection Control and Hospital Epidemiology, 29(2), pp.131~136 (2008)
  29. Thompson,R.E, "Incidence of ventilatorassociated pneumonia (VAP) with 14-day circuit change in a subacute environment", Respiratory Care, 41(7), pp.601~606 (1996)

관련 논문AI추천