초록

Purpose: Fluid-attenuated inversion recovery (FLAIR) imaging can be obtained faster with shorter repletion time (TR), but it gets noisier. We hypothesized that shorter- TR FLAIR obtained at 3 tesla (3T) with a 32-channel coil may be comparable to conventional FLAIR. The aim of this study was to compare the diagnostic value between conventional FLAIR (TR = 9000 ms, FLAIR9000) and shorter-TR FLAIR (TR = 6000 ms, FLAIR6000) at 3T in terms of diffusion-weighted imaging-FLAIR mismatch. Materials and Methods: We recruited 184 patients with acute ischemic stroke (28 patients < 4.5 hours) who had undergone 5-mm diffusion-weighted imaging (DWI) and two successive 5-mm FLAIR images (no gap; in-plane resolution, 0.9 x 0.9 mm) at 3T with a 32-channel coil. The acquisition times for FLAIR9000 and FLAIR6000 were 108 seconds (generalized autocalibrating partially parallel acquisitions [GRAPPA] = 2) and 60 seconds (GRAPPA = 3), respectively. Two radiologists independently assessed the paired imaging sets (DWI-FLAIR9000 and DWI-FLAIR6000) for the presence of matched hyperintense lesions on each FLAIR imaging. The signal intensity ratios (area of DWI lesion to contralateral normal-appearing region) on both FLAIR imaging sets were compared. Results: DWI-FLAIR9000 mismatch was present in 39 of 184 (21.2%) patients, which was perfectly the same on FLAIR6000. Three of 145 patients (2%) with DWImatched lesions on FLAIR9000 had discrepancy on FLAIR6000, showing no significant difference (P > 0.05). Interobserver agreement was excellent for both DWI-FLAIR9000 and DWI-FLAIR6000 (k = 0.904 and 0.883, respectively). Between the two FLAIR imaging sets, there was no significant difference of signal intensity ratio (mean, standard deviation; 1.25 ± 0.20; 1.24 ± 0.20, respectively) (P > 0.05). Conclusion: For the determination of mismatch or match between DWI and FLAIR imaging, there is no significant difference between FLAIR9000 and FLAIR6000 at 3T with a 32-channel coil.

Abstract

Purpose: Fluid-attenuated inversion recovery (FLAIR) imaging can be obtained faster with shorter repletion time (TR), but it gets noisier. We hypothesized that shorter- TR FLAIR obtained at 3 tesla (3T) with a 32-channel coil may be comparable to conventional FLAIR. The aim of this study was to compare the diagnostic value between conventional FLAIR (TR = 9000 ms, FLAIR9000) and shorter-TR FLAIR (TR = 6000 ms, FLAIR6000) at 3T in terms of diffusion-weighted imaging-FLAIR mismatch. Materials and Methods: We recruited 184 patients with acute ischemic stroke (28 patients < 4.5 hours) who had undergone 5-mm diffusion-weighted imaging (DWI) and two successive 5-mm FLAIR images (no gap; in-plane resolution, 0.9 x 0.9 mm) at 3T with a 32-channel coil. The acquisition times for FLAIR9000 and FLAIR6000 were 108 seconds (generalized autocalibrating partially parallel acquisitions [GRAPPA] = 2) and 60 seconds (GRAPPA = 3), respectively. Two radiologists independently assessed the paired imaging sets (DWI-FLAIR9000 and DWI-FLAIR6000) for the presence of matched hyperintense lesions on each FLAIR imaging. The signal intensity ratios (area of DWI lesion to contralateral normal-appearing region) on both FLAIR imaging sets were compared. Results: DWI-FLAIR9000 mismatch was present in 39 of 184 (21.2%) patients, which was perfectly the same on FLAIR6000. Three of 145 patients (2%) with DWImatched lesions on FLAIR9000 had discrepancy on FLAIR6000, showing no significant difference (P > 0.05). Interobserver agreement was excellent for both DWI-FLAIR9000 and DWI-FLAIR6000 (k = 0.904 and 0.883, respectively). Between the two FLAIR imaging sets, there was no significant difference of signal intensity ratio (mean, standard deviation; 1.25 ± 0.20; 1.24 ± 0.20, respectively) (P > 0.05). Conclusion: For the determination of mismatch or match between DWI and FLAIR imaging, there is no significant difference between FLAIR9000 and FLAIR6000 at 3T with a 32-channel coil.

참고문헌 (18)

  1. Hacke W, "Association of outcome with early stroke treatment: pooled analysis of ATLANTIS, ECASS, and NINDS rt-PA stroke trials", Lancet, 363, pp.766~774 (2004)
  2. Del Zoppo GJ, "American Heart Association Stroke Council. Expansion of the time window for treatment of acute ischemic stroke with intravenous tissue plasminogen activator: a science advisory from the American Heart Association", American Stroke Association, 2009, pp.40, 2945~2948
  3. Balami JS, "The exact science of stroke thrombolysis and the quiet art of patient selection", Brain, 136, pp.3528~3553 (2013)
  4. European Stroke Organisation (ESO) Executive Committee, "Guidelines for management of ischaemic stroke and transient ischaemic attack 2008", Cerebrovasc Dis, 25, pp.457~507 (2008)
  5. Adams HP Jr, "Guidelines for the early management of adults with ischemic stroke: a guideline from the American Heart Association", American Stroke Association Stroke Council, Clinical Cardiology Council, Cardiovascular Radiology and Intervention Council, and the Atherosclerotic Peripheral Vascular Disease and Quality of Care Outcomes in Research Interdisciplinary Working Groups: The American Academy of Neurology affirms the value of this guideline as an educational tool for neurologists, 2007, pp.115, e478~e534
  6. Barber PA, "Why are stroke patients excluded from TPA therapy? An analysis of patient eligibility", Neurology, 56, pp.1015~1020 (2001)
  7. Thomalla G, "Negative fluid-attenuated inversion recovery imaging identifies acute ischemic stroke at 3 hours or less", Ann Neurol, 65, pp.724~732 (2009)
  8. Thomalla G, "DWI-FLAIR mismatch for the identification of patients with acute ischaemic stroke within 4.5 h of symptom onset (PREFLAIR):a multicentre observational study", Lancet Neurol, 10, pp.978~986 (2011)
  9. Petkova M, "MR imaging helps predict time from symptom onset in patients with acute stroke: implications for patients with unknown onset time", Radiology, 257, pp.782~792 (2010)
  10. Koga M, "THrombolysis for Acute Wake-up and unclear-onset Strokes with alteplase at 0.6mg", kg (THAWS) Trial, 2014, pp.9, 1117~1124
  11. Thomalla G, "A multicenter, randomized, double-blind, placebo-controlled trial to test efficacy and safety of magnetic resonance imaging-based thrombolysis in wake-up stroke (WAKE-UP)", Int J Stroke, 9, pp.829~836 (2014)
  12. Nael K, "Six-minute magnetic resonance imaging protocol for evaluation of acute ischemic stroke: pushing the boundaries", Stroke, 45, pp.1985~1991 (2014)
  13. Griswold MA, "Generalized autocalibrating partially parallel acquisitions (GRAPPA)", Magn Reson Med, 47, pp.1202~1210 (2002)
  14. Wiesinger F, "Potential and feasibility of parallel MRI at high field", NMR Biomed, 19, pp.368~378 (2006)
  15. Meshksar A, "Role of EPI-FLAIR in patients with acute stroke: a comparative analysis with FLAIR", AJNR Am J Neuroradiol, 35, pp.878~883 (2014)
  16. Galinovic I, "Visual and region of interest-based inter-rater agreement in the assessment of the diffusion-weighted imaging- fluid-attenuated inversion recovery mismatch", Stroke, 45, pp.1170~1172 (2014)
  17. Saver JL, "Time is brain--quantified", Stroke, 37, pp.263~266 (2006)
  18. Gagoski BA, "RARE", turbo spin echo imaging with simultaneous multislice wave-CAIPI, 2015, pp.73, 929~938

관련 논문AI추천

The Role of Double Inversion Recovery Imaging in Acute Ischemic Stroke류창우, 박순찬, 이정민, 장건호, 최나영대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2019 · 제23권 제3호Fast MRI in Acute Ischemic Stroke: Applications of MRI Acceleration Techniques for MR-Based Comprehensive Stroke Imaging김병준, Bo Kyu Kim, Sang Eun Park, Sung-Hye You대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2021 · 제25권 제2호Does the ADC Map have Additional Clinical Significance Compared to the DWI in the Brain Infarction?강명진, 윤성국, 이진화, 최순섭, 하동호대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2013 · 제17권 제4호Susceptibility Weighted MR Imaging at 3T in Patients with Occlusion of Middle Cerebral Artery : Comparison with Diffusion Weighted Imaging Score (ASPECTS)김범수, 심희진, 안국진, 정소령, 최현석대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2011 · 제15권 제3호The Added Value of Double Dose Gadolinium Enhanced 3D T2 Fluid-Attenuated Inversion Recovery for Evaluating Small Brain Metastases안성준, 이승구, 장종희, 정태섭연세대학교의과대학 · Yonsei Medical Journal2014 · 제55권 제5호Role of Perfusion-Weighted Imaging in a Diffusion- Weighted-Imaging-Negative Transient Ischemic Attack강동화, 권순억, 김종성, 나현욱, 안성호, 이상헌대한신경과학회 · Journal of Clinical Neurology2017 · 제13권 제2호

이 간행물의 다른 논문 (9건)