Optimal Cardiac Magnetic Resonance Contrast-Enhanced Timing Robust Angiography (CMR-CENTRA) for the Three-Dimensional Reconstruction of the Bilateral Atria in the Electroanatomic Mapping (EAM) of Atrial Fibrillation
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Purpose: To optimize the timing of scans using cardiac magnetic resonance contrastenhanced timing robust angiography (CMR-CENTRA) for electroanatomic mapping (EAM) of the right atrium (RA) and left atrium (LA) in patients with atrial fibrillation (AF). Materials and Methods: Fifty patients with AF (38 men; mean age, 59.6 ± 9.3 years) underwent CMR-CENTRA in preparation for EAM. The CMR-CENTRA data were acquired at five different scan times: 0 seconds, 5 seconds, 10 seconds, 15 seconds, and 20 seconds after an intravenous injection of contrast media. To evaluate the degree of contrast enhancement, right atrial relative contrast (RA-RC) and left atrial relative contrast (LA-RC) on the CMR-CENTRA scans were assessed at each time point. The three-dimensional (3D) reconstruction of the RA and LA for the EAM system was performed using the CMR-CENTRA data. Results: A CMR-CENTRA at a scan time of 10 seconds showed significantly greater LA-RC (P < 0.05) compared with all other scan times. A CMR-CENTRA at a scan time of 15 seconds showed significantly greater RA-RC (P < 0.05) compared with all other scan times. In the 3D reconstruction of the RA, the success rates of CMR-CENTRA at scan times of 10 seconds and 15 seconds were 18% and 100%, respectively. In the 3D reconstruction of the LA, the success rates of CMR-CENTRA at 10- and 15-second scan times were 100%. Conclusion: The CMR-CENTRA data acquired at 15 seconds after the injection of contrast media is appropriate for the preparation of an EAM system that is focused on the RA and LA in patients with AF.
Abstract
Purpose: To optimize the timing of scans using cardiac magnetic resonance contrastenhanced timing robust angiography (CMR-CENTRA) for electroanatomic mapping (EAM) of the right atrium (RA) and left atrium (LA) in patients with atrial fibrillation (AF). Materials and Methods: Fifty patients with AF (38 men; mean age, 59.6 ± 9.3 years) underwent CMR-CENTRA in preparation for EAM. The CMR-CENTRA data were acquired at five different scan times: 0 seconds, 5 seconds, 10 seconds, 15 seconds, and 20 seconds after an intravenous injection of contrast media. To evaluate the degree of contrast enhancement, right atrial relative contrast (RA-RC) and left atrial relative contrast (LA-RC) on the CMR-CENTRA scans were assessed at each time point. The three-dimensional (3D) reconstruction of the RA and LA for the EAM system was performed using the CMR-CENTRA data. Results: A CMR-CENTRA at a scan time of 10 seconds showed significantly greater LA-RC (P < 0.05) compared with all other scan times. A CMR-CENTRA at a scan time of 15 seconds showed significantly greater RA-RC (P < 0.05) compared with all other scan times. In the 3D reconstruction of the RA, the success rates of CMR-CENTRA at scan times of 10 seconds and 15 seconds were 18% and 100%, respectively. In the 3D reconstruction of the LA, the success rates of CMR-CENTRA at 10- and 15-second scan times were 100%. Conclusion: The CMR-CENTRA data acquired at 15 seconds after the injection of contrast media is appropriate for the preparation of an EAM system that is focused on the RA and LA in patients with AF.
참고문헌 (21)
- Fuster V, "ACC", AHA, American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation): developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society, pp.Circulation, 2006[DOI]
- European Heart Rhythm Association, "ACC", AHA, American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation), pp.J Am Coll Cardiol, 2006[DOI]
- Haissaguerre M, "Catheter ablation of long-lasting persistent atrial fibrillation : critical structures for termination", J Cardiovasc Electrophysiol, 16, pp.1125~1137 (2005)
- Oral H, "A randomized assessment of the incremental role of ablation of complex fractionated atrial electrograms after antral pulmonary vein isolation for long-lasting persistent atrial fibrillation", J Am Coll Cardiol, 53, pp.782~789 (2009)
- Nademanee K, "A new approach for catheter ablation of atrial fibrillation : mapping of the electrophysiologic substrate", J Am Coll Cardiol, 43, pp.2044~2053 (2004)
- Hwang SH, "Relation between left atrial wall composition by late gadolinium enhancement and complex fractionated atrial electrograms in patients with persistent atrial fibrillation : influence of non-fibrotic substrate in the left atrium", Int J Cardiovasc Imaging, 31, pp.1191~1199 (2015)
- Dabir D, "High-resolution motion compensated MRA in patients with congenital heart disease using extracellular contrast agent at 3 Tesla", J Cardiovasc Magn Reson, 14, pp.75~ (2012)
- Schonberger M, "Time-resolved MR venography of the pulmonary veins precatheter-based ablation for atrial fibrillation", J Magn Reson Imaging, 37, pp.127~137 (2013)
- 윤연이, "2014 Korean Guidelines for Appropriate Utilization of Cardiovascular Magnetic Resonance Imaging: A Joint Report of the Korean Society of Cardiology and the Korean Society of Radiology", Korean Circulation Journal, 44(6), pp.359~385 (2014), 대한심장학회
- Heist EK, "Factors affecting error in integration of electroanatomic mapping with CT and MR imaging during catheter ablation of atrial fibrillation", J Interv Card Electrophysiol, 17, pp.21~27 (2006)
- Bertaglia E, "Integration of three-dimensional left atrial magnetic resonance images into a real-time electroanatomic mapping system : validation of a registration method", Pacing Clin Electrophysiol, 31, pp.273~282 (2008)
- Jeong HJ, "Time-resolved magnetic resonance angiography : evaluation of intrapulmonary circulation parameters in pulmonary arterial hypertension", J Magn Reson Imaging, 33, pp.225~231 (2011)
- Shrout PE, "Intraclass correlations : uses in assessing rater reliability", Psychol Bull, 86, pp.420~428 (1979)
- Giesel FL, "Three-dimensional multiphase time-resolved low-dose contrast-enhanced magnetic resonance angiography using TWIST on a 32-channel coil at 3 T : a quantitative and qualitative comparison of a conventional gadolinium chelate with a high-relaxivity agent", J Comput Assist Tomogr, 34, pp.678~683 (2010)
- Malik SB, "The right atrium : gateway to the heart--anatomic and pathologic imaging findings", Radiographics, 35, pp.14~31 (2015)
- Callan P, "Right heart catheterisation : indications and interpretation", Heart, 102, pp.147~157 (2016)
- Hwang SH, "Assessment of cor triatriatum dexter and giant eustachian valve with cardiac magnetic resonance", Circulation, 130, pp.1727~1729 (2014)
- Ho SY, "Anatomy of the left atrium : implications for radiofrequency ablation of atrial fibrillation", J Cardiovasc Electrophysiol, 10, pp.1525~1533 (1999)
- Lacomis JM, "Multi-detector row CT of the left atrium and pulmonary veins before radio-frequency catheter ablation for atrial fibrillation", Radiographics, 23, pp.S35~S48 (2003)
- Groarke JD, "Feasibility study of electrocardiographic and respiratory gated, gadolinium enhanced magnetic resonance angiography of pulmonary veins and the impact of heart rate and rhythm on study quality", J Cardiovasc Magn Reson, 16, pp.43~ (2014)
- Hwang SH, "Atrial fibrillation : relationship between left atrial pressure and left atrial appendage emptying determined with velocityencoded cardiac MR imaging", Radiology, 284, pp.381~389 (2017)