원통형 물체 쥐기 시 건강한 성인과 척수마비 환자의 최대 손가락 끝 힘 분포 비교
Comparison of Maximum Fingertip Force Distribution in Cylindrical Grasping Between Healthy Adults and Patients With Spinal Cord Injury
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background: It is known that hand strength and fingertip force are used as an indicator of muscle strength and are also highly related to the various chronic symptoms and even lifes-pan. To use the individual fingertip force (IFF) as a quantitative index for clinical evaluation, the IFF should be measured and analyzed with various variables from various subjects, such as the normal range of fingertip force and the difference in its distribution by disease. Objects: We tried to measure and analyze the mean maximum IFF distribution during grasp-ing a cylindrical object in healthy adults and patients with spinal cord injury (SCI). Methods: Five Force-sensitive resistor (FSR) sensors were attached to the fingertips of 24 healthy people and 13 patients with SCI. They were asked to grip the object three times for five seconds with their maximum effort. Results: The mean maximum IFF of the healthy adult group’s thumb, index, and middle fin-ger was similar statistically and showed relatively larger than IFF of the ring and small finger. It is a 3-point pinch grip pattern. All fingertip forces of patients with SCI decreased by more than 50% to the healthy group, and their IFF of the middle finger was relatively the largest among the five fingertip forces. The cervical level injured SCI patients showed significantly decreased IFFs compared to thoracic level injured SCI patients. Conclusion: We expect that this study results would be helpful for rehabilitation diagnosis and therapy goal decision with robust further study.
Abstract
Background: It is known that hand strength and fingertip force are used as an indicator of muscle strength and are also highly related to the various chronic symptoms and even lifes-pan. To use the individual fingertip force (IFF) as a quantitative index for clinical evaluation, the IFF should be measured and analyzed with various variables from various subjects, such as the normal range of fingertip force and the difference in its distribution by disease. Objects: We tried to measure and analyze the mean maximum IFF distribution during grasp-ing a cylindrical object in healthy adults and patients with spinal cord injury (SCI). Methods: Five Force-sensitive resistor (FSR) sensors were attached to the fingertips of 24 healthy people and 13 patients with SCI. They were asked to grip the object three times for five seconds with their maximum effort. Results: The mean maximum IFF of the healthy adult group’s thumb, index, and middle fin-ger was similar statistically and showed relatively larger than IFF of the ring and small finger. It is a 3-point pinch grip pattern. All fingertip forces of patients with SCI decreased by more than 50% to the healthy group, and their IFF of the middle finger was relatively the largest among the five fingertip forces. The cervical level injured SCI patients showed significantly decreased IFFs compared to thoracic level injured SCI patients. Conclusion: We expect that this study results would be helpful for rehabilitation diagnosis and therapy goal decision with robust further study.
참고문헌 (39)
- Nordin M, "Basic biomechanics of the musculoskeletal system", pp.691~748 (2012), Baltimore(MD) : Lippincott Williams & Wilkins
- Feix T, "The GRASP taxonomy of human grasp types", IEEE Trans Hum Mach Syst, 46(1), pp.66~77 (2016)
- Ranganathan VK, "Effects of aging on hand function", J Am Geriatr Soc, 49(11), pp.1478~1484 (2001)
- Gurram R, "Grip pressure distribution under static and dynamic loading", Exp Mech, 33(3), pp.169~173 (1993)
- Musalek C, "Grip strength as an indicator of health-related quality of life in old age-a pilot study", Int J Environ Res Public Health, 14(12), pp.1447~ (2017)
- Bohannon RW, "Dynamometer measurements of hand-grip strength predict multiple outcomes", Percept Mot Skills, 93(2), pp.323~328 (2001)
- Stenholm S, "Long-term determinants of muscle strength decline : prospective evidence from the 22-year mini-Finland follow-up survey", J Am Geriatr Soc, 60(1), pp.77~85 (2012)
- Cheung CL, "Association of handgrip strength with chronic diseases and multimorbidity:a cross-sectional study", Age(Dordr), 35(3), pp.929~941 (2013)
- Rijk JM, "Prognostic value of handgrip strength in people aged 60 years and older : a systematic review and meta-analysis", Geriatr Gerontol Int, 16(1), pp.5~20 (2016)
- Lee J, "Associations between handgrip strength and diseasespecific mortality including cancer, cardiovascular, and respiratory diseases in older adults: a meta-analysis", J Aging Phys Act, 28(2), pp.320~331 (2020)
- Picon RV, "Trends in prevalence of hypertension in Brazil : a systematic review with meta-analysis", PLoS One, 7(10), pp.e48255~ (2012)
- Jenmalm P, "Visual and tactile information about object-curvature control fingertip forces and grasp kinematics in human dexterous manipulation", J Neurophysiol, 84(6), pp.2984~2997 (2000)
- Diermayr G, "Finger force coordination underlying object manipulation in the elderly-a minireview", Gerontology, 57(3), pp.217~227 (2011)
- Cole KJ, "Grasp force control in older adults", J Mot Behav, 23(4), pp.251~258 (1991)
- Kinoshita H, "A comparison of prehension force control in young and elderly individuals", Eur J Appl Physiol Occup Physiol, 74(5), pp.450~460 (1996)
- Cole KJ, "Mechanisms for age-related changes of fingertip forces during precision gripping and lifting in adults", J Neurosci, 19(8), pp.3238~3247 (1999)
- Ehrsson HH, "Cortical activity in precision-versus powergrip tasks : an fMRI study", J Neurophysiol, 83(1), pp.528~536 (2000)
- Ehrsson HH, "Differential fronto-parietal activation depending on force used in a precision grip task : an fMRI study", J Neurophysiol, 85(6), pp.2613~2623 (2001)
- Ehrsson HH, "Evidence for the involvement of the posterior parietal cortex in coordination of fingertip forces for grasp stability in manipulation", J Neurophysiol, 90(5), pp.2978~2986 (2003)
- Kinoshita H, "Functional brain areas used for the lifting of objects using a precision grip : a PET study", Brain Res, 857(1-2), pp.119~130 (2000)
- Kuhtz-Buschbeck JP, "Human brain activity in the control of fine static precision grip forces : an fMRI study", Eur J Neurosci, 14(2), pp.382~390 (2001)
- Schmitz C, "Brain activity during predictable and unpredictable weight changes when lifting objects", J Neurophysiol, 93(3), pp.1498~1509 (2005)
- Ehrsson HH, "Holding an object : neural activity associated with fingertip force adjustments to external perturbations", J Neurophysiol, 97(2), pp.1342~1352 (2007)
- Zariffa J, "Feasibility and efficacy of upper limb robotic rehabilitation in a subacute cervical spinal cord injury population", Spinal Cord, 50(3), pp.220~226 (2012)
- Zariffa J, "Relationship between clinical assessments of function and measurements from an upper-limb robotic rehabilitation device in cervical spinal cord injury", IEEE Trans Neural Syst Rehabil Eng, 20(3), pp.341~350 (2012)
- Mekki M, "Robotic rehabilitation and spinal cord injury : a narrative review", Neurotherapeutics, 15(3), pp.604~617 (2018)
- Francisco GE, "Robot-assisted training of arm and hand movement shows functional improvements for incomplete cervical spinal cord injury", Am J Phys Med Rehabil, 96(10 Suppl 1), pp.171~177 (2017)
- Cappello L, "Assisting hand function after spinal cord injury with a fabric-based soft robotic glove", J Neuroeng Rehabil, 15(1), pp.59~ (2018)
- Schabowsky CN, "Development and pilot testing of HEXORR : hand EXOskeleton rehabilitation robot", J Neuroeng Rehabil, 7, pp.36~ (2010)
- Nakanishi T, "Remarkable hand grip steadiness in individuals with complete spinal cord injury", Exp Brain Res, 237(12), pp.3175~3183 (2019)
- Zariffa J, "Changes in hand muscle synergies in subjects with spinal cord injury : characterization and functional implications", J Spinal Cord Med, 35(5), pp.310~318 (2012)
- "FlexiForceTM standard model A201" (2021)[URL]
- Martim P, "Smart object for physical rehabilitation assessment", Paper presented at : 2018International Conference and Exposition on Electrical and Power Engineering(EPE), pp.0678~0682 (2018), IEEE
- Fess EE, "Clinical assessment recommendations" (1981), American Society of Hand Therapists
- Mathiowetz V, "Reliability and validity of grip and pinch strength evaluations", J Hand Surg Am, 9(2), pp.222~226 (1984)
- Pylatiuk C, "Distribution of grip force in three different functional prehension patterns", J Med Eng Technol, 30(3), pp.176~182 (2006)
- Stival F, "A quantitative taxonomy of human hand grasps", J Neuroeng Rehabil, 16(1), pp.28~ (2019)
- Hall RS, "A technique for conditioning and calibrating force-sensing resistors for repeatable and reliable measurement of compressive force", J Biomech, 41(16), pp.3492~3495 (2008)
- J. A. Florez, "Calibration of force sensing resistors (fsr) for static and dynamic applications", 2010 IEEE ANDESCON, pp.14~17 (2010), IEEE
