Background: Office workers experience neck or back pain due to poor posture, such as flexed head and forward head posture, during long-term sedentary work. Posture correction is used to reduce pain caused by poor posture and ensures proper alignment of the body. Sev-eral assistive devices have been developed to assist in maintaining an ideal posture; however, there are limitations in practical use due to vast size, unproven long-term effects or inconsis-tency of maintaining posture alignment. We developed a headphone and necklace posture correction system (HANPCS) for posture correction using an inertial measurement unit (IMU) sensor that provides visual or auditory feedback. Objects: To demonstrate the test-retest reliability and concurrent validity of neck and upper trunk flexion measurements using a HANPCS, compared with a three-dimensional motion analysis system (3DMAS). Methods: Twenty-nine participants were included in this study. The HANPCS was applied to each participant. The angle for each action was measured simultaneously using the HANPCS and 3DMAS. The data were analyzed using the intraclass correlation coefficient (ICC) = [3,3] with 95% confidence intervals (CIs). Results: The angular measurements of the HANPCS for neck and upper trunk flexions showed high intra- (ICC = 0.954–0.971) and inter-day (ICC = 0.865–0.937) values, standard error of measurement (SEM) values (1.05°–2.04°), and minimal detectable change (MDC) values (2.92°–5.65°). Also, the angular measurements between the HANPCS and 3DMAS had excel-lent ICC values (> 0.90) for all sessions, which indicates high concurrent validity. Conclusion: Our study demonstrates that the HANPCS is as accurate in measuring angle as the gold standard, 3DMAS. Therefore, the HANPCS is reliable and valid because of its angular measurement reliability and validity.

Abstract

Background: Office workers experience neck or back pain due to poor posture, such as flexed head and forward head posture, during long-term sedentary work. Posture correction is used to reduce pain caused by poor posture and ensures proper alignment of the body. Sev-eral assistive devices have been developed to assist in maintaining an ideal posture; however, there are limitations in practical use due to vast size, unproven long-term effects or inconsis-tency of maintaining posture alignment. We developed a headphone and necklace posture correction system (HANPCS) for posture correction using an inertial measurement unit (IMU) sensor that provides visual or auditory feedback. Objects: To demonstrate the test-retest reliability and concurrent validity of neck and upper trunk flexion measurements using a HANPCS, compared with a three-dimensional motion analysis system (3DMAS). Methods: Twenty-nine participants were included in this study. The HANPCS was applied to each participant. The angle for each action was measured simultaneously using the HANPCS and 3DMAS. The data were analyzed using the intraclass correlation coefficient (ICC) = [3,3] with 95% confidence intervals (CIs). Results: The angular measurements of the HANPCS for neck and upper trunk flexions showed high intra- (ICC = 0.954–0.971) and inter-day (ICC = 0.865–0.937) values, standard error of measurement (SEM) values (1.05°–2.04°), and minimal detectable change (MDC) values (2.92°–5.65°). Also, the angular measurements between the HANPCS and 3DMAS had excel-lent ICC values (> 0.90) for all sessions, which indicates high concurrent validity. Conclusion: Our study demonstrates that the HANPCS is as accurate in measuring angle as the gold standard, 3DMAS. Therefore, the HANPCS is reliable and valid because of its angular measurement reliability and validity.

참고문헌 (46)

  1. Brown WJ, "Sitting time and work patterns as indicators of overweight and obesity in Australian adults", Int J Obes Relat Metab Disord, 27(11), pp.1340~1346 (2003)
  2. 이원휘, "컴퓨터 작업시 책상과 체간사이 거리가 전방 머리 자세와 목과 어깨 근육들의 근 활성도에 미치는 영향", 대한물리의학회지, 8(4), pp.601~608 (2013), 대한물리의학회
  3. Burgess-Limerick R, "The effect of imposed and self-selected computer monitor height on posture and gaze angle", Clin Biomech(Bristol, Avon), 13(8), pp.584~592 (1998)
  4. Jung-Ho Kang, "The Effect of The Forward Head Posture on Postural Balance in Long Time Computer Based Worker", Annals of Rehabilitation Medicine, 36(1), pp.98~104 (2012), 대한재활의학회
  5. Lee KS, "Analysis of the change of the forward head posture according to computer using time", J Korean Soc Phys Med, 4(2), pp.117~124 (2009)
  6. Côté P, "The burden and determinants of neck pain in workers", Eur Spine J, 17(Suppl 1), pp.60~74 (2008)
  7. Florencio LL, "Analysis of head posture and activation of the cervical neck extensors during a low-load task in women with chronic migraine and healthy participants", J Manipulative Physiol Ther, 41(9), pp.762~770 (2018)
  8. Mahmoud NF, "The relationship between forward head posture and neck pain : a systematic review and meta-analysis", Curr Rev Musculoskelet Med, 12(4), pp.562~577 (2019)
  9. Patwardhan AG, "Cervical sagittal balance : a biomechanical perspective can help clinical practice", Eur Spine J, 27(Suppl 1), pp.25~38 (2018)
  10. Vasavada AN, "Gravitational demand on the neck musculature during tablet computer use", Ergonomics, 58(6), pp.990~1004 (2015)
  11. Janwantanakul P, "Prevalence of self-reported musculoskeletal symptoms among office workers", Occup Med, 58(6), pp.436~438 (2008)
  12. Bhardwaj Y, "Prevalence of neck pain and disability in computer users", IJSR, 6(8), pp.1288~1290 (2015)
  13. Hafeez K, "Back pain-are health care undergraduates at risk?", Iran J Public Health, 42(8), pp.819~825 (2013)
  14. Poitras S, "Management of work-related low back pain : a population-based survey of physical therapists", Phys Ther, 85(11), pp.1168~1181 (2005)
  15. Park SY, "Effect of EMG-based feedback on posture correction during computer operation", J Occup Health, 54(4), pp.271~277 (2012)
  16. Kendall FP, "Muscles: testing and function with posture and pain" (2005), Lippincott Williams &Wilkins
  17. Claus AP, "Is 'ideal' sitting posture real? Measurement of spinal curves in four sitting postures", Man Ther, 14(4), pp.404~408 (2009)
  18. Carcone SM, "Effects of backrest design on biomechanics and comfort during seated work", Appl Ergon, 38(6), pp.755~764 (2007)
  19. Annetts S, "A pilot investigation into the effects of different office chairs on spinal angles", Eur Spine J, 21(Suppl 2), pp.S165~ (2012)
  20. Baumgartner D, "The spinal curvature of three different sitting positions analysed in an open MRI scanner", ScientificWorldJournal, 2012, pp.184016~ (2012)
  21. Grondin DE, "The effect of a lumbar support pillow on lumbar posture and comfort during a prolonged seated task", Chiropr Man Therap, 21(1), pp.21~ (2013)
  22. Çelenay ŞT, "Spinal postural training:comparison of the postural and mobility effects of electrotherapy, exercise, biofeedback trainer in addition to postural education in university students", J Back Musculoskelet Rehabil, 28(1), pp.135~144 (2015)
  23. Yoo WG, "Effects of a proximity-sensing feedback chair on head, shoulder, and trunk postures when working at a visual display terminal.", J Occup Rehabil, 16(4), pp.631~637 (2006)
  24. Raya R, "An inexpensive and easy to use cervical range of motion measurement solution using inertial sensors", Sensors(Basel), 18(8), pp.2582~ (2018)
  25. Ailneni RC, "Influence of the wearable posture correction sensor on head and neck posture : sitting and standing workstations", Work, 62(1), pp.27~35 (2019)
  26. Kuo YL, "Sitting posture during prolonged computer typing with and without a wearable biofeedback sensor", Int J Environ Res Public Health, 18(10), pp.5430~ (2021)
  27. Kim A, "Initial calibration of an inertial measurement unit using an optical position tracking system", Paper presented at: PLANS 2004. Position Location and Navigation Symposium (IEEE Cat. No.04CH37556), pp.96~101 (2004)
  28. 김문식, "Development of a High-Precision Calibration Method for Inertial Measurement Unit", International Journal of Precision Engineering and Manufacturing, 15(3), pp.567~575 (2014), 한국정밀공학회
  29. Bonett DG, "Sample size requirements for estimating intraclass correlations with desired precision", Stat Med, 21(9), pp.1331~1335 (2002)
  30. Walter SD, "Sample size and optimal designs for reliability studies", Stat Med, 17(1), pp.101~110 (1998)
  31. Anoro-Hervera A, "Intra-rater and inter-rater reliability of cervical active range of movement in young asymptomatic adults using inertial sensors", Expert Rev Med Devices, 16(12), pp.1071~1077 (2019)
  32. Song KJ, "Cross-cultural adaptation and validation of the Korean version of the neck disability index", Spine(Phila Pa 1976), 35(20), pp.E1045~9 (2010)
  33. Yoon TL, "Validity and reliability of an inertial measurement unit-based 3-dimensional angular measurement of cervical range of motion", J Manipulative Physiol Ther, 42(1), pp.75~81 (2019)
  34. Nolze G, "Euler angles and crystal symmetry", Cryst Res Technol, 50(2), pp.188~201 (2015)
  35. Brink Y, "Development of a cost effective three-dimensional posture analysis tool : validity and reliability", BMC Musculoskelet Disord, 14, pp.335~ (2013)
  36. Yi CH, "Advanced data analysis for physical therapists and occupational therapists" (2021), Gyechuk Munhwasa
  37. Atkinson G, "Statistical methods for assessing measurement error(reliability)in variables relevant to sports medicine", Sports Med, 26(4), pp.217~238 (1998)
  38. Portney LG, "Foundations of clinical research: applications to practice", pp.2009, Pearson
  39. Bland JM, "Statistical methods for assessing agreement between two methods of clinical measurement", Int J Nurs Stud, 47(8), pp.931~936 (2010)
  40. 전인철, "Reliability and Validity of Measurement Using Smartphone ­Based Goniometer of Tibial External Rotation Angle in Standing Knee Flexion", 한국전문물리치료학회지, 20(2), pp.60~68 (2013), 한국전문물리치료학회[DOI]
  41. Webster KE, "Three dimensional motion analysis of within and between day repeatability of tibial rotation during pivoting", Knee, 17(5), pp.329~333 (2010)
  42. Theobald PS, "Do inertial sensors represent a viable method to reliably measure cervical spine range of motion?", Man Ther, 17(1), pp.92~96 (2012)
  43. Quek J, "Validity and intra-rater reliability of an android phone application to measure cervical range-of-motion", J Neuroeng Rehabil, 11, pp.65~ (2014)
  44. Jones A, "Concurrent validity and reliability of the Simple Goniometer iPhone app compared with the Universal Goniometer", Physiother Theory Pract, 30(7), pp.512~516 (2014)
  45. Kong KA, "Statistical methods : reliability assessment and method comparison", Ewha Med J, 40(1), pp.9~16 (2017)
  46. Taylor JD, "Intrarater reliability of the KT1000arthrometer in determining anterior translation of the glenohumeral joint", Arch Phys Med Rehabil, 86(4), pp.826~829 (2005)

관련 논문AI추천

이 간행물의 다른 논문 (9건)