Odor management is significantly concerned with sustainable livestock production because odor nuisance is a primary cause for complaint to neighbors. This study was conducted to measure the concentration of odorous compounds, odor intensity, and odor offensiveness at unit process in animal waste treatment facility combined composting and methane fermentation process by an instrumental analysis and direct olfactory method. Ammonia, sulfur-containing compounds, and volatile fatty acid were analyzed at each process units and boundary area in summer and winter, respectively. Higher concentration of odorants occurred in the summer than in the winter due to high ambient temperature. The maximum concentration of odorants was detected in composting pile when mixed manure was being turned followed by inlet, curing, outlet, and screen & packing process. Highest concentration of detected odorous compounds was ammonia ranging from 3.4 to 224.7 ppm. Among the sulfur-containing compounds measured, hydrogen sulfide was a maximum level of 2.3 ppm and most of them exceeded reported odor detection thresholds. Acetic acid was the largest proportion of VFA generated, reaching a maximum of 51 to 89%, followed by propionic and butyric acid at 1.9 to 35% and 1.8 to 15%, respectively. Malodor assessment by a human panel appeared a similar tendency in instrumental analysis data. Odor quotient for predicting major odor-causing compounds was calculated by dividing concentrations measured in process units by odor detection thresholds. In the composting process, hydrogen sulfide, ammonia, dimethyl sulfide, and methyl mercaptan were deeply associated with odor-causing compounds, while the major malodor compounds in the inlet process were methyl mercaptan, hydrogen sulfide, and butyric acid.
Abstract
Odor management is significantly concerned with sustainable livestock production because odor nuisance is a primary cause for complaint to neighbors. This study was conducted to measure the concentration of odorous compounds, odor intensity, and odor offensiveness at unit process in animal waste treatment facility combined composting and methane fermentation process by an instrumental analysis and direct olfactory method. Ammonia, sulfur-containing compounds, and volatile fatty acid were analyzed at each process units and boundary area in summer and winter, respectively. Higher concentration of odorants occurred in the summer than in the winter due to high ambient temperature. The maximum concentration of odorants was detected in composting pile when mixed manure was being turned followed by inlet, curing, outlet, and screen & packing process. Highest concentration of detected odorous compounds was ammonia ranging from 3.4 to 224.7 ppm. Among the sulfur-containing compounds measured, hydrogen sulfide was a maximum level of 2.3 ppm and most of them exceeded reported odor detection thresholds. Acetic acid was the largest proportion of VFA generated, reaching a maximum of 51 to 89%, followed by propionic and butyric acid at 1.9 to 35% and 1.8 to 15%, respectively. Malodor assessment by a human panel appeared a similar tendency in instrumental analysis data. Odor quotient for predicting major odor-causing compounds was calculated by dividing concentrations measured in process units by odor detection thresholds. In the composting process, hydrogen sulfide, ammonia, dimethyl sulfide, and methyl mercaptan were deeply associated with odor-causing compounds, while the major malodor compounds in the inlet process were methyl mercaptan, hydrogen sulfide, and butyric acid.
참고문헌 (27)
- Both, R., "Directive on odour in ambient air : an established system of odour measurement and odour regulation in Germany", Wat. Sci. Technol, 44, pp.119~126 (2001)
- Burton, C. H., "The effect of farm scale aerobic treatment of piggery slurry on odour concentration, intensity and offensiveness", J. Agric. Engng. Res, 71, pp.203~211 (1998)
- Edeogu, I., "Odour emission rates from manure treatment", storage systems, 2001, pp.44(9), 269~275
- Odor emission from a swine finishing facility with a surface aerated lagoon, "Heber, A. J", ASAE, ~, pp.ASAE Paper No. 994129 (1999)
- Kuroda, K., "Emissions of malodorous compounds and green- house gases from composting swine feces", Bioresour. Technol, 56, pp.265~271 (1996)
- Mackie, R. I., "Biochemical identification and biological origin of key odour components in livestock waste", J. Anim. Sci, 76, pp.1331~1342 (1998)
- Mahin, T. D, "Comparison of different approaches used to regulate odours around world", Wat. Sci. Tech, 44(9), pp.87~102 (2001)
- McGinn, S. M., "Atmospheric ammonia, volatile fatty acids, and other odorants near beef feedlots", J. Environ. Qual, 32, pp.1173~1182 (2003)
- Merrill, L, "Seasonal variation in microbial communities and organic malodor indicator compound concentrations in various types of swine manure storage systems", J. Environ. Qual, 31, pp.2074~2085 (2002)
- Miner, J. R, "Characterization of odors and other volatile emissions", Agric. Environ, 3(2-3), pp.129~137 (1977)
- National Institute for Occupational Safety and Health, "Manual of Analytical Method(4th Ed. )", ~ (1994)
- Powers, W. J., "Odour control for livestock system", J. Anim. Sci, 77(Suppl. 2), pp.169~176 (1999)
- Rappert, S., "Odor compounds in waste gas emissions from agricultural operations and food industries", Waste Manage, 25, pp.887~907 (2005)
- Reisner, A. E., "Newspaper coverage of controversies about large-scale swine facilities in rural communities in Illinois", J. Anim. Sci, 83, pp.2705~2712 (2005)
- Schlegelmilch, M., "Odour management and treatment tech- nologies: An overview", Waste Manage, 25, pp.928~939 (2005)
- Sommer, S. G., "Ammonia volatilization from sow on grassland", Atmos. Environ, 35, pp.2023~2032 (2001)
- Varel, V. H., "Effect of carvacrol and thymol on odour emissions from livestock wastes", Wat. Sci. Tech, 44, pp.143~148 (2001)
- Whitehead, T. R., "Isolation and Identification of hyper-ammonia producing bacteria from swine manure storage pits", Curr. Microbiol, 48, pp.20~26 (2004)
- Zahn, J. A., "Correlation of human olfactory response to airborne concentrations of malodorous volatile organic compounds emitted from swine effluent", J. Environ. Qual, 30, pp.624~634 (2001)
- Zhu, J., "A review of microbiology in swine manure odour control", Agric. Ecosystems and Environ, 78, pp.93~106 (2000)
- 고한종, "액상 가축분뇨의 처리 및 토양환원에 따른 악취 및 악취물질의 평가", 한국동물자원과학회지, 48(3), pp.453~466 (2006), 한국동물자원과학회
- 김기연, "한강유역내 축분퇴비공장 악취발생에 대한 현장 평가", 동물자원과학회지, 43(6), pp.1005~1018 (2001)
- 박귀환, "축산시설의 악취 특성에 관한 연구", 실내환경 및 냄새 학회지, 4(4), pp.207~215 (2005), 한국냄새환경학회
- 유용희, "돈사 내 및 부지경계에서 악취물질 발생 조사 연구", 축산시설환경학회지, 11(1), pp.45~54 (2005)
- 장영기, "축산시설에서 발생되는 악취의 축종별 특성에 대한 설문조사", 환경영향평가, 13(1), pp.33~40 (2004)
- 홍대웅, "축산폐수처리시설에서 발생하는 악취물질 배출특성 - 복합악취 및 12가지 지정악취물질을 중심으로 -", 실내환경 및 냄새 학회지, 6(1), pp.1~9 (2007), 한국냄새환경학회
- 환경부, "악취방지법 시행규칙", ~ (2005)