초분광 카메라 검출기의 비선형성에 대한 복사보정 방안 연구
Radiometric Calibration Method with Compensation of Nonlinearity of Detector for Hyper-Spectral Camera
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
In this paper, we propose a novel radiometric calibration method which can effectively compensate the nonlinearity of the detector for hyper-spectral camera. In general, the detector of hyper-spectral camera can produce nonlinear output depending on radiance and integral time. The conventional radiometric calibration methods extract the imprecise radiance profile from the spectral profile of the target due to this nonlinearity. In our proposed method, we use a quadratic equation instead of a linear equation to describe the relation between output of detector and radiance. Then, we use a fractional function to compensate variation of integration time. Thus, our proposed method can extract more precise spectral profile of radiance than conventional radiometric calibration method.
Abstract
In this paper, we propose a novel radiometric calibration method which can effectively compensate the nonlinearity of the detector for hyper-spectral camera. In general, the detector of hyper-spectral camera can produce nonlinear output depending on radiance and integral time. The conventional radiometric calibration methods extract the imprecise radiance profile from the spectral profile of the target due to this nonlinearity. In our proposed method, we use a quadratic equation instead of a linear equation to describe the relation between output of detector and radiance. Then, we use a fractional function to compensate variation of integration time. Thus, our proposed method can extract more precise spectral profile of radiance than conventional radiometric calibration method.
참고문헌 (12)
- Hong, Suk-Min, "Image Acquisition and Analysis by Hyper Spectral Sensor", The Korea Institute of Military Science and Technology, Annual Conference Journal, 2, pp.591~594 (2002)
- 이규성, "초분광 원격탐사의 특성, 처리기법 및 활용 현황", 대한원격탐사학회지, 21(4), pp.341~369 (2005), 대한원격탐사학회
- 정준호, "적외선 카메라를 이용한 복사량 계측 및 교정 연구", 한국컴퓨터정보학회논문지, 20(4), pp.57~67 (2015), 한국컴퓨터정보학회
- Kim, Yeon-Soo, "Military use of Hyper Spectral Technology", Optical science and technology, 16(4), pp.36~40 (2012)
- 장안진, "CASI 초분광 영상을 이용한 RapidEye 위성영상의 대리복사보정", 한국지형공간정보학회지, 23(3), pp.3~10 (2015), 한국지형공간정보학회[DOI]
- 최세운, "전임상 혈관분석을 위한 초분광 이미징 시스템의 활용", 한국컴퓨터정보학회논문지, 20(4), pp.69~76 (2015), 한국컴퓨터정보학회
- 양정규, "초분광 영상획득을 위한 단적외선 센서의 실시간 상대복사보정 기법 연구", 한국컴퓨터정보학회논문지, 21(11), pp.1~7 (2016), 한국컴퓨터정보학회
- 신정일, "지상 초분광카메라 영상의 복사보정", 대한원격탐사학회지, 24(2), pp.213~222 (2008), 대한원격탐사학회
- Michael T Eismann, "Hyperspectral remote sensing", pp.725~ (2012), SPIE press
- Zadnik, J, "Calibration procedures and measurements for the COMPASS hyperspectral imager", Proc. SPIE, 5425, pp.182~188 (2004)
- Green, R. O, "Imaging Spectroscopy and the Airborne Visible", Infrared Imaging Spectrometer (AVIRIS), 1998, pp.65, 227~248
- Thomas G. Chrien, "Accuracy of the spectral and radiometric laboratory calibration of the Airborne Visible", Infrared Imaging Spectrometer, 1990, pp.37, ~