완만한 쐐기형 Tail Mass를 갖는 선형배열 수중음향변환기의 FOM (Figure of Merit) 성능특성 개선
Improved FOM (Figure of Merit) Performance Characteristics of a Linear Array Underwater Acoustic Transducer with a Gradual Wedge-shaped Tail Mass
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
A linear array acoustic transducer with 12 tonpilz elements mounted independently on a gradual wedge-shaped tail mass was fabricated, tested and analyzed. The compensated transducer, which is modified by including a series inductance of 137 μH in the developed linear array transducer, attained improved figure of merit (FOM) performance characteristics compared with the uncompensated transducer. The four resonant frequency bands were identified from the measured FOM curve. The FOM response patterns over the frequency ranges of 31 to 40 kHz and 50 to 60 kHz were relatively uniform, whereas sharp resonance peaks were observed at around 73 kHz and 84 kHz. These results indicate that the developed linear array transducer can be used as an enhanced broadband transducer of echo sounder, and the operating frequency can be selected for more effective echo surveys in the fishing ground.
Abstract
A linear array acoustic transducer with 12 tonpilz elements mounted independently on a gradual wedge-shaped tail mass was fabricated, tested and analyzed. The compensated transducer, which is modified by including a series inductance of 137 μH in the developed linear array transducer, attained improved figure of merit (FOM) performance characteristics compared with the uncompensated transducer. The four resonant frequency bands were identified from the measured FOM curve. The FOM response patterns over the frequency ranges of 31 to 40 kHz and 50 to 60 kHz were relatively uniform, whereas sharp resonance peaks were observed at around 73 kHz and 84 kHz. These results indicate that the developed linear array transducer can be used as an enhanced broadband transducer of echo sounder, and the operating frequency can be selected for more effective echo surveys in the fishing ground.
참고문헌 (15)
- Airmar Technology Corporation, "Technical data catalog", 316~376 (2017)
- Coates R, "Multiple-mode acoustic transducer calculations", IEEE Trans Ultrason Ferroelect Freq Contr, 36, pp.471~473 (1989)
- Dong Y, "Analysis of a new joint time-frequency distribution of suppressing cross-term", Res J Appl Sci Eng Technol, 4, pp.1580~1584 (2012)
- Juan Ramon Gonzalez Hernandez, "Low-Cost, Wideband Ultrasonic Transmitter and Receiver for Array Signal Processing Applications", IEEE Sensors Journal, 11(5), pp.1284~1292 (2011), Institute of Electrical and Electronics Engineers (IEEE)[DOI]
- Computer modeling of ultrasonic piezoelectric transducers, "Hughes WJ", Applied Research Lab, The Pennsylvania State University, 1~116, pp.Technical report TR 96-007 (1969)
- 이대재, "40-75 kHz의 주파수 범위에서 동작하는 광대역 초음파 변환기의 설계 및 개발", 한국수산과학회지, 47(3), pp.292~301 (2014), 한국수산과학회
- 이대재, "12 주파수의 48 tonpilz 진동소자를 이용한 광대역 초음파 모자이크 변환기의 대역폭 확장", 한국수산과학회지, 47(3), pp.302~312 (2014), 한국수산과학회
- 이대재, "활어 개체어의 광대역 음향산란신호로부터 어종식별을 위한 시간-주파수 특징 추출", 한국수산과학회지, 49(2), pp.214~223 (2016), 한국수산과학회
- 이대재, "다중 공진 광대역 음향변환기의 대역폭 개선", 한국수산과학회지, 50(5), pp.605~615 (2017), 한국수산과학회[DOI]
- 이대재, "대역통과 정합회로를 이용한 수중음향변환기의 대역폭 확장", 한국수산과학회지, 52(6), pp.702~708 (2019), 한국수산과학회[DOI]
- Lowrance Electronics, "Marine electronics catalog", 8~14 (2017)
- Radmanovic M, "Design and modeling of the power ultrasonic transducers", pp.131~133 (2004), MP Interconsulting
- I.E. Kuznetsova, "The power flow angle of acoustic waves in thin piezoelectric plates", IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 55(9), pp.1984~1991 (2008), Institute of Electrical and Electronics Engineers (IEEE)[DOI]
- Stansfield D, "Underwater electroacoustic transducers", pp.73~103 (1991), Bath University Press
- Wilson OB, "Introduction to theory and design of sonar transducers", pp.21~42 (1988), Peninsula Publishing