Purpose This study investigated setup error and effectiveness of weekly image-guided radiotherapy(IGRT) of TomoDirect for early breast cancer. Materials and MethodsOne hundred and fifty-one breasts of 147 consecutive patients who underwent breastconserving surgery followed by whole breast irradiation using TomoDirect in 2012 and 2013were evaluated. All patients received weekly IGRT. The weekly setup errors from simulationto each treatment in reference to chest wall and surgical clips were measured. Random,systemic, and 3-dimensional setup errors were assessed. Extensive setup error wasdefined as 5 mm above the margin in any directions. ResultsAll mean errors were within 3 mm of all directions. The mean angle of gantry shifts was0.6°. The mean value of absolute 3-dimensional setup error was 4.67 mm. In multivariateanalysis, breast size (odds ratio, 2.82; 95% confidence interval, 1.00 to 7.90) was a significantfactor for extensive error. The largest significant deviation of setup error was observedin the first week of radiotherapy (p < 0.001) and the deviations gradually decreased withtime. The deviation of setup error was 5.68 mm in the first week and within 5 mm after thesecond week. ConclusionIn this study, there was a significant association between breast size and significant setuperror in breast cancer patients who received TomoDirect. The largest deviation occurred inthe first week of treatment. Therefore, patients with large breasts should be closely observedon every fraction and fastidious attention is required in the first fraction of IGRT.

Abstract

Purpose This study investigated setup error and effectiveness of weekly image-guided radiotherapy(IGRT) of TomoDirect for early breast cancer. Materials and MethodsOne hundred and fifty-one breasts of 147 consecutive patients who underwent breastconserving surgery followed by whole breast irradiation using TomoDirect in 2012 and 2013were evaluated. All patients received weekly IGRT. The weekly setup errors from simulationto each treatment in reference to chest wall and surgical clips were measured. Random,systemic, and 3-dimensional setup errors were assessed. Extensive setup error wasdefined as 5 mm above the margin in any directions. ResultsAll mean errors were within 3 mm of all directions. The mean angle of gantry shifts was0.6°. The mean value of absolute 3-dimensional setup error was 4.67 mm. In multivariateanalysis, breast size (odds ratio, 2.82; 95% confidence interval, 1.00 to 7.90) was a significantfactor for extensive error. The largest significant deviation of setup error was observedin the first week of radiotherapy (p < 0.001) and the deviations gradually decreased withtime. The deviation of setup error was 5.68 mm in the first week and within 5 mm after thesecond week. ConclusionIn this study, there was a significant association between breast size and significant setuperror in breast cancer patients who received TomoDirect. The largest deviation occurred inthe first week of treatment. Therefore, patients with large breasts should be closely observedon every fraction and fastidious attention is required in the first fraction of IGRT.

참고문헌 (22)

  1. Veronesi U, "Twenty-year follow-up of a randomized study comparing breast-conserving surgery with radical mastectomy for early breast cancer", N Engl J Med, 347, pp.1227~1232 (2002)
  2. Clarke M, "Effects of radiotherapy and of differences in the extent of surgery for early breast cancer on local recurrence and 15-year survival : an overview of the randomised trials", Lancet, 366, pp.2087~2106 (2005)
  3. Early Breast Cancer Trialists' Collaborative Group(EBCTCG), "Effect of radiotherapy after breast-conserving surgery on 10-year recurrence and 15-year breast cancer death : metaanalysis of individual patient data for 10, 801 women in 17randomised trials", Lancet, 378, pp.1707~1716 (2011)
  4. Badakhshi H, "Image-guided volumetric modulated arc therapy for breast cancer : a feasibility study and plan comparison with threedimensional conformal and intensity-modulated radiotherapy", Br J Radiol, 86, pp.20130515~ (2013)
  5. Chang SX, "A comparison of different intensity modulation treatment techniques for tangential breast irradiation", Int J Radiat Oncol Biol Phys, 45, pp.1305~1314 (1999)
  6. Jin GH, "A comparative dosimetric study for treating left-sided breast cancer for small breast size using five different radiotherapy techniques : conventional tangential field, filed-in-filed, tangential-IMRT, multi-beam IMRT and VMAT", Radiat Oncol, 8, pp.89~ (2013)
  7. Vicini FA, "Optimizing breast cancer treatment efficacy with intensity-modulated radiotherapy", Int J Radiat Oncol Biol Phys, 54, pp.1336~1344 (2002)
  8. Franco P, "Intensity-modulated adjuvant whole breast radiation delivered with static angle tomotherapy(TomoDirect) : a prospective case series", J Cancer Res Clin Oncol, 139, pp.1927~1936 (2013)
  9. Franco P, "Intensity-modulated and hypofractionated simultaneous integrated boost adjuvant breast radiation employing statics ports of tomotherapy(TomoDirect) : a prospective phase II trial", J Cancer Res Clin Oncol, 140, pp.167~177 (2014)
  10. "Brassiere measurement"[URL]
  11. "NSABP B-39, RTOG 0413: A randomized phase III study of conventional whole breast irradiation versus partial breast irradiation for women with stage 0, I, or II breast cancer", Clin Adv Hematol Oncol, 4, pp.719~721 (2006)
  12. Li XA, "Variability of target and normal structure delineation for breast cancer radiotherapy : an RTOG multi-institutional and multiobserver study", Int J Radiat Oncol Biol Phys, 73, pp.944~951 (2009)
  13. Stroom JC, "Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability", Int J Radiat Oncol Biol Phys, 43, pp.905~919 (1999)
  14. Yang DS, "Set-up uncertainty during breast radiotherapy. Image-guided radiotherapy for patients with initial extensive variation", Strahlenther Onkol, 189, pp.315~320 (2013)
  15. Furuya T, "The dosimetric impact of respiratory breast movement and daily setup error on tangential whole breast irradiation using conventional wedge, field-in-field and irregular surface compensator techniques", J Radiat Res, 54, pp.157~165 (2013)
  16. 정미주, "Tumor bed volumetric changes during breast irradiation for the patients with breast cancer", Radiation oncology journal, 31(4), pp.228~233 (2013), 대한방사선종양학회
  17. Lirette A, "The role of electronic portal imaging in tangential breast irradiation : a prospective study", Radiother Oncol, 37, pp.241~245 (1995)
  18. Topolnjak R, "Breast patient setup error assessment : comparison of electronic portal image devices and cone-beam computed tomography matching results", Int J Radiat Oncol Biol Phys, 78, pp.1235~1243 (2010)
  19. Offerman S, "Effect of breast volume on treatment reproducibility on a tomotherapy unit in the treatment of breast cancer", Int J Radiat Oncol Biol Phys, 80, pp.417~421 (2011)
  20. 이종훈, "Predictors of Axillary Lymph Node Metastases (ALNM) in a Korean Population with T1-2 Breast Carcinoma: Triple Negative Breast Cancer has a High Incidence of ALNM Irrespective of the Tumor Size", Cancer Research and Treatment, 42(1), pp.30~36 (2010), 대한암학회
  21. Richter A, "Effect of breathing motion in radiotherapy of breast cancer : 4D dose calculation and motion tracking via EPID", Strahlenther Onkol, 185, pp.425~430 (2009)
  22. Bert C, "Clinical experience with a 3D surface patient setup system for alignment of partial-breast irradiation patients", Int J Radiat Oncol Biol Phys, 64, pp.1265~1274 (2006)

이 간행물의 다른 논문 (49건)