Abstract

Since the occlusal loading is transmitted to the surrounding bone, the success of an implant treatment is closely related to the distribution of the stress on the implant. The finite element analysis method is often used in order to produce a model for dispersion of stress. Assessment of the success of the implant is usually based on the degree of osseointegration which is a bone and implant surface interface. Implant used in this research was designed through the method of shape optimization after the stress on implant was anaylzed by the finite element analysis method. This study was pertinently assessed by a clinical, histologic, histomorphometric analysis after the shape optimized implant was installed on beagle dog tibia. The results are as follows 1. It clinically showed a good result without mobility and imflammatory reaction. 2. Implant was supported by dense bone and bone remodeling showed on the surrounding area of the implant 3. The average percentage of bone-implant contact was 58.1%.The percentage of bone density was 57.6%. Having above results, shape optimized implant showed the pertinence through clinical and histologic aspects. However, to use the shape optimized implant, the further experiment is required for finding problems, improvement.

참고문헌 (33)

  1. "Intraosseous anchorage of dental prostheses A requiem for the periodontal ligament The long-term efficacy of currently used dental implants a review and proposed criteria of success Longterm evaluation of nonsubmerged ITI implants Part1 8year life table analysis of a prospective multi-center study with 2359 implants The biomechanics of force distribution in implant-supported prostheses Internatonal Journal of Oral & Maxillofacial Implants 1993 Evaluating Parameters of osseointergrated dental implants using finite elements analysis - a two - dimensional comparative study examining the effects of implant diameter Comparison of screw loosening and deflection among three implant designs Journal of Prosthetic Dentistry 1995 Biomechanical consideration in osseointegrated prostheses", pp.81 88 11 161 80 270 153 843~100 91 25 172 8 278 201 848, nemark P-I
  2. "Finite element analysis of a new system(IL) for supporting an implant-retained cantilever prosthesis", 10(3), pp.355~366 (1995)
  3. "Craniofacial osseointegrated implant-induced strain distribute numerical study", 12(2), pp.200~210 (1997)
  4. "Comparison of stress transmission in the IMZ implant system polyoxymethylene or titanium intramobile element Peri-implat tissue at submerged and non-submerged titanium implants Journal of Clinical Periodontology 1989", pp.450 600~607
  5. "The elastic and ultimate properties of compact bone tissue", pp.393~405
  6. "Marginal tissue reactions at osseintegrated titanium fixtures International journal of Oral & Maxillofacial Surgery 1986", pp.39~52, nemark
  7. "Fixture design and overload influence marginal boneloss and fixture success in the Brä", pp.104~111, nemark system
  8. "A three-dimensional finite element analysis of bone around dental implants in an edentulous human mandible", 38, pp.491~196 (1993)
  9. "The influence of a flexible coating on the bone stress around dental implants", 22(2), pp.105~111 (1995)
  10. "A comparative evaluation of mandibular finite element models with different lengths and elements for implants biomechanics", 25(4), pp.299~303 (1998)
  11. "Evaluation of design parameters of osseointegrated dental implants using finite elements", 29, pp.565~574 (2002)
  12. "“치과용 임프란트의 형상과 계면 응력의 상관관계”", pp.128~131 (2002)
  13. "“치과용 임플란트의 형상에 대한 매개변수 해석”" (2002), 제26회 대한의용생체공학회 춘계
  14. "“A New Method of Structural Shape Optimization Based on Biological Growth ” International Journal of Fatigue 1990"
  15. "” in R", pp.109~126
  16. "Tissue reaction to an implant of a titanium hollow cylinder with a titanium surface spray layer", pp.713~27
  17. "Temperature threshlod levels for heat-induced bone tissue injury A vital micorscopic study in the rabbit", pp.101~7
  18. "Histomorphometry of bone apposition around three types ofdental implants", in press
  19. "Titanium impalnts in rabbit knee joints", pp.256~269 (1987)
  20. "Osseous adaptation to continuous loading of rigid endosseous implants", 86, pp.95~111 (1984)
  21. "immedeate functional loading of Branema가 single tooth implants.An 18month follow-up study", 11, pp.26~33 (2001)
  22. "A 1-year follow-up of implants of differing surface roughness placed in rabbit bone", 12, pp.486~494 (1997)
  23. "Quantified bone tissue reactions to various metallic materials with reference to the so-called osseointegration concept University of Toronto Press 1991", pp.357~363
  24. "A removal torque and histomorphometric study of commercially pure nobium and titanium implant in rabbit bone", pp.24~29
  25. "Influence of surface characteristics on bone integration of titanium iplants A histomorphometric study in miniature pigs Journal of Biomedical Materials Reserch 1991", pp.889~902
  26. "Peri-implat tissue at submerged and non-submerged titanium implants Journal of Clinical Periodontology 1989", pp.600~607
  27. "The excessive loss of Brä nemark fixtures in type IV bone", pp.2~4
  28. "Eary failures in 4 A study from stage I surgery to the connection of completed prostheses", pp.641 142~146, nemark dental implants
  29. "Bone-implnat contact on machined and dual acid-etched surfaces after 2months of healing in the human maxilla", 74, pp.945~956 (2003)
  30. "Comparison of screw loosening, rotation, and deflection among three implant designs", 74, pp.270~278 (1995)
  31. "Evaluating Parameters of osseointergrated dental implants using finite elements analysis - a two - dimensional comparative study examining the effects of implant diameter, implant shape, and load direction", 24(2), pp.80~88 (1998)
  32. "The biomechanics of force distribution in implant-supported prostheses", 8, pp.19~27 (1993)
  33. "Longterm evaluation of nonsubmerged ITI implants Part1:8year life table analysis of a prospective multi-center study with 2359 implants", 8, pp.161~172 (1997)

관련 논문AI추천