Background:Previous studies have shown that if performed without radiographic guidance, the loss of resistance (LOR) technique can result in inaccurate needle placement in up to 30% of lumbar epidural blocks. To date, no study has shown the efficacy of measuring the depth of the posterior complex (ligamentum flavum, epidural space, and posterior dura) ultrasonographically to distinguish true and false LOR. Methods:40 cervical epidural blocks were performed using the LOR technique and confirmed by epidurograms. Transverse ultrasound images of the C6/7 area were taken before each cervical epidural block, and the distances from the skin to the posterior complex, transverse process, and supraspinous ligament were measured on each ultrasound view. The number of LOR attempts was counted, and the depth of each LOR was measured with a standard ruler. Correlation of false and true positive LOR depth with ultrasonographically measured depth was also statistically analyzed. Results:76.5% of all cases (26 out of 34) showed false positive LOR. Concordance correlation coefficients between the measured distances on ultrasound (skin to ligamentum flavum) and actual needle depth were 0.8285 on true LOR. Depth of the true positive LOR correlated with height and weight, with a mean of 5.64 ± 1.06 cm, while the mean depth of the false positive LOR was 4.08 ± 1.00 cm. Conclusions:Ultrasonographic measurement of the ligamentum flavum depth (or posterior complex) preceding cervical epidural block is beneficial in excluding false LOR and increasing success rates of cervical epidural blocks.
Abstract
Background:Previous studies have shown that if performed without radiographic guidance, the loss of resistance (LOR) technique can result in inaccurate needle placement in up to 30% of lumbar epidural blocks. To date, no study has shown the efficacy of measuring the depth of the posterior complex (ligamentum flavum, epidural space, and posterior dura) ultrasonographically to distinguish true and false LOR. Methods:40 cervical epidural blocks were performed using the LOR technique and confirmed by epidurograms. Transverse ultrasound images of the C6/7 area were taken before each cervical epidural block, and the distances from the skin to the posterior complex, transverse process, and supraspinous ligament were measured on each ultrasound view. The number of LOR attempts was counted, and the depth of each LOR was measured with a standard ruler. Correlation of false and true positive LOR depth with ultrasonographically measured depth was also statistically analyzed. Results:76.5% of all cases (26 out of 34) showed false positive LOR. Concordance correlation coefficients between the measured distances on ultrasound (skin to ligamentum flavum) and actual needle depth were 0.8285 on true LOR. Depth of the true positive LOR correlated with height and weight, with a mean of 5.64 ± 1.06 cm, while the mean depth of the false positive LOR was 4.08 ± 1.00 cm. Conclusions:Ultrasonographic measurement of the ligamentum flavum depth (or posterior complex) preceding cervical epidural block is beneficial in excluding false LOR and increasing success rates of cervical epidural blocks.
참고문헌 (22)
- Castagnera L, "Long-term results of cervical epidural steroid injection with and without morphine in chronic cervical radicular pain", Pain, 58, pp.239~243 (1994)
- Ferrante FM, "Clinical classification as a predictor of therapeutic outcome after cervical epidural steroid injection", Spine, 18, pp.730~736 (1993)
- Rowlingson JC, "Epidural analgesic techniques in the management of cervical pain", Anesth Analg, 65, pp.938~942 (1986)
- Waldman SD, "Cervical epidural abscess after cervical epidural nerve block with steroids", Anesth Analg, 72, pp.717~718 (1991)
- Williams KN, "Epidural haematoma requiring surgical decompression following repeated cervical epidural steroid injections for chronic pain", Pain, 42, pp.197~199 (1990)
- Abram SE, "Complications associated with epidural steroid injections", Reg Anesth, 21, pp.149~162 (1996)
- Hodges SD, "Cervical epidural steroid injection with intrinsic spinal cord damage. Two case reports", Spine, 23, pp.2137~2142 (1998)
- White AH, "Injection techniques for the diagnosis and treatment of low back pain", Orthop Clin North Am, 14, pp.553~567 (1983)
- Hogan QH, "Epidural anatomy examined by cryomicrotome section. Influence of age, vertebral level, and disease", Reg Anesth, 21, pp.395~406 (1996)
- Stojanovic MP, "The role of fluoroscopy in cervical epidural steroid injections: an analysis of contrast dispersal patterns", Spine, 27, pp.509~514 (2002)
- Kim SH, "Sonographic estimation of needle depth for cervical epidural blocks", Anesth Analg, 106, pp.1542~1547 (2008)
- Fredman B, "Epidural steroids for treating "failed back surgery syndrome": is fluoroscopy really necessary?", Anesth Analg, 88, pp.367~372 (1999)
- Wulf H, "Radiologic position control of epidural catheters (epidurography). An instrument of quality assurance for regional analgesia", Anaesthesist, 42, pp.536~544 (1993)
- Cork RC, "Ultrasonic localization of the lumbar epidural space", Anesthesiology, 52, pp.513~516 (1980)
- Wallace DH, "Indirect sonographic guidance for epidural anesthesia in obese pregnant patients", Reg Anesth, 17, pp.233~236 (1992)
- Arzola C, "Ultrasound using the transverse approach to the lumbar spine provides reliable landmarks for labor epidurals", Anesth Analg, 104, pp.1188~1192 (2007)
- Balki M, "Ultrasound imaging of the lumbar spine in the transverse plane: the correlation between estimated and actual depth to the epidural space in obese parturients", Anesth Analg, 108, pp.1876~1881 (2009)
- Bonazzi M, "Ultrasonography-guided identification of the lumbar epidural space", Minerva Anestesiol, 61, pp.201~205 (1995)
- Ferre RM, "Ultrasound identification of landmarks preceding lumbar puncture: a pilot study", Emerg Med J, 26, pp.276~277 (2009)
- Chin KJ, "An ultrasound-assisted approach facilitates spinal anesthesia for total joint arthroplasty", Can J Anaesth, 56, pp.643~650 (2009)
- Grau T, "Ultrasound imaging of the thoracic epidural space", Reg Anesth Pain Med, 27, pp.200~206 (2002)
- Pandin P, "Combined ultrasound and nerve stimulation-guided thoracic epidural catheter placement for analgesia following anterior spine fusion in scoliosis", Pain Pract, 9, pp.230~234 (2009)