본문 바로가기
KERD
논문KCI 등재

Tissue reactions to suture materials in the oral mucosa of beagle dogs

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Purpose: The objective of this study was to compare and evaluate the inflammatory responses of three widely used suture materials in the keratinized gingiva and buccal mucosa of beagle dogs. Methods: Silk, polyglycolic acid, and nylon sutures were placed within the mandibular keratinized gingiva and maxillary buccal mucosa of four male beagle dogs. Biopsies were taken 3, 7, and 14 days after suturing. Specimens were prepared with hematoxylin-eosin stain for evaluation under a light microscope. Results: The suture materials placed in the oral mucosa elicited more inflammatory reactions than did those placed in the keratinized gingiva. The multifilament suture materials caused more inflammatory tissue reactions than did the monofilament suture materials in the oral mucosa. Conclusions: If oral hygiene is well maintained and suture materials are placed in the keratinized gingiva, silk, nylon, and polyglycolic acid are considered to be proper suture materials for oral surgery. However, it is advisable to use monofilament suture materials if the suture site is within the oral mucosa.

Abstract

Purpose: The objective of this study was to compare and evaluate the inflammatory responses of three widely used suture materials in the keratinized gingiva and buccal mucosa of beagle dogs. Methods: Silk, polyglycolic acid, and nylon sutures were placed within the mandibular keratinized gingiva and maxillary buccal mucosa of four male beagle dogs. Biopsies were taken 3, 7, and 14 days after suturing. Specimens were prepared with hematoxylin-eosin stain for evaluation under a light microscope. Results: The suture materials placed in the oral mucosa elicited more inflammatory reactions than did those placed in the keratinized gingiva. The multifilament suture materials caused more inflammatory tissue reactions than did the monofilament suture materials in the oral mucosa. Conclusions: If oral hygiene is well maintained and suture materials are placed in the keratinized gingiva, silk, nylon, and polyglycolic acid are considered to be proper suture materials for oral surgery. However, it is advisable to use monofilament suture materials if the suture site is within the oral mucosa.

참고문헌 (25)

  1. Shaw RJ, "A prospective clinical evaluation of the longevity of resorbable sutures in oral mucosa", Br J Oral Maxillofac Surg, 34, pp.252~254 (1996)
  2. Swanson NA, "Suture materials, 1980s: properties, uses, and abuses", Int J Dermatol, 21, pp.373~378 (1982)
  3. Cohen ES, "Atlas of cosmetic and reconstructive periodontal surgery. 3rd ed" (2007), BC Decker
  4. Grigg TR, "Effect of the wicking behavior of multifilament sutures", J Endod, 30, pp.649~652 (2004)
  5. Ivanoff CJ, "Nonresorbable versus resorbable sutures in oral implant surgery: a prospective clinical study", Clin Implant Dent Relat Res, 3, pp.57~60 (2001)
  6. Craig PH, "A biologic comparison of polyglactin 910 and polyglycolic acid synthetic absorbable sutures", Surg Gynecol Obstet, 141, pp.1~10 (1975)
  7. Silverstein LH, "Principles of dental suturing: the complete guide to surgical closure" (1999), Montage Media Co
  8. Selvig KA, "Oral tissue reactions to suture materials", Int J Periodontics Restorative Dent, 18, pp.474~487 (1998)
  9. Sanz L, "Mechanisms of wound healing, suture material, and wound closure, strategies in gynecologic surgery" (1986), Springer
  10. Yaltirik M, "Comparison of four different suture materials in soft tissues of rats", Oral Dis, 9, pp.284~286 (2003)
  11. Leknes KN, "Human gingival tissue reactions to silk and expanded polytetrafluoroethylene sutures", J Periodontol, 76, pp.34~42 (2005)
  12. Lilly GE, "Reaction of oral tissues to suture materials. II", Oral Surg Oral Med Oral Pathol, 26, pp.592~599 (1968)
  13. Rothenburger S, "In vitro antimicrobial evaluation of Coated VICRYL* Plus Antibacterial Suture (coated polyglactin 910 with triclosan) using zone of inhibition assays", Surg Infect (Larchmt), 3(1), pp.S79~S87 (2002)
  14. Gabrielli F, "Suture materials and other factors associated with tissue reactivity, infection, and wound dehiscence among plastic surgery outpatients", Plast Reconstr Surg, 107, pp.38~45 (2001)
  15. Castelli WA, "Cheek mucosa response to silk, cotton, and nylon suture materials", Oral Surg Oral Med Oral Pathol, 45, pp.186~189 (1978)
  16. Racey GL, "Comparison of a polyglycolic-polylactic acid suture to black silk and plain catgut in human oral tissues", J Oral Surg, 36, pp.766~770 (1978)
  17. Blomstedt B, "Suture material and bacterial transport. An experimental study", Acta Chir Scand, 143, pp.71~73 (1977)
  18. King RC, "Bacteremia following intraoral suture removal", Oral Surg Oral Med Oral Pathol, 65, pp.23~28 (1988)
  19. Blumenthal NM, "A clinical comparison of collagen membranes with e-PTFE membranes in the treatment of human mandibular buccal class II furcation defects", J Periodontol, 64, pp.925~933 (1993)
  20. Cardaropoli G, "Dynamics of bone tissue formation in tooth extraction sites. An experimental study in dogs", J Clin Periodontol, 30, pp.809~818 (2003)
  21. Romanos GE, "Health human periodontal versus peri-implant gingival tissues: an immunohistochemical differentiation of the extracellular matrix", Int J Oral Maxillofac Implants, 10, pp.750~758 (1995)
  22. Lilly GE, "Reaction of oral tissues to suture materials", Oral Surg Oral Med Oral Pathol, 26, pp.128~133 (1968)
  23. Sortino F, "Silk and polyglycolic acid in oral surgery: a comparative study", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 105, pp.e15~e18 (2008)
  24. Gabel EA, "Performance comparison of nylon and an absorbable suture material (Polyglactin 910) in the closure of punch biopsy sites", Dermatol Surg, 26, pp.750~752 (2000)
  25. Leknes KN, "Tissue reactions to sutures in the presence and absence of anti-infective therapy", J Clin Periodontol, 32, pp.130~138 (2005)

관련 논문AI추천

Evaluation of tensile strength of surgical synthetic absorbable suture materials: an in vitro studyAshish Sham Nichani, Sujeet Vinayak Khiste, V. Ranganath대한치주과학회 · Journal of Periodontal & Implant Science2013 · 제43권 제3호Distance of insertion points in a mattress suture from the wound margin for ideal primary closure in alveolar mucosa: an in vitro experimental study이원호, 이정석, 차재국, Andreas Stavropoulos, Ulrike Kuchler대한치주과학회 · Journal of Periodontal & Implant Science2021 · 제51권 제3호Comparison of interrupted and locked continuous suture techniques in oral surgery regarding wound healing: a split-mouth clinical trialGökhan Gürses, Şeyma Koyuncu대한구강악안면외과학회 · 대한구강악안면외과학회지2025 · 제51권 제1호Local tissue effects of various barrier membranes in a rat subcutaneous model임현창, Christoph H. F. Hämmerle, Daniel S. Thoma, Franz-Josef Strauss, Nadja Naenni, Ronald E. Jung대한치주과학회 · Journal of Periodontal & Implant Science2020 · 제50권 제5호백서 피하층에서 흡수성 차단막의 초기 조직 반응김종관, 김창성, 이용근, 임현창, 정의원, 조규성, 채경준, 최성호대한치주과학회 · Journal of Periodontal & Implant Science2007 · 제37권 제4호Comparing intra-oral wound healing after alveoloplasty using silk sutures and n-butyl-2-cyanoacrylateAditi Saha, Gandhali Limaye, Pranav Sathe, Pratik Suthar, Pushkar Waknis, Sonal Shah대한구강악안면외과학회 · 대한구강악안면외과학회지2020 · 제46권 제1호

이 간행물의 다른 논문 (5건)