표면처리 시간에 따른 임플란트 미세구조의 변화: HA와 양극산화 표면 임플란트
Micromorphometric change of implant surface conditioned with tetracycline-HCl : HA and oxidized surface
1
조회
0
다운로드
0
인용
0
참고문헌
초록
Abstract
The present study was performed to evaluate the effect of tetracycline-HCL on the change of implant surface microstructure according to application time. Implant with pure titanium machined surface, HA-coated surface and TiUniteTM surface were utilized. Implant surface was rubbed with 50㎎/㎖ tetracycline-HCL solution for ½min., 1min., 1½min., 2min., and 2½min. respectively in the test group. Then, specimens were processed for scanning electron micro- scopic observation. The results of this study were as follows. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. In HA-coated surfaces, round particles were deposited irregularly. The roughness of surfaces conditioned with tetracycline-HCL was lessened and the cracks were increased relative to the application time. 3. The anodic oxidized surfaces showed the craterous structures. The surface conditioning with tetracycline-HCl didn't influence on its micro-morphology. In conclusion, the detoxification with 50㎎/㎖ tetracycline-HCL must be applied respectively with different time according to various implant surfaces.
참고문헌 (47)
- "Osseointegrated implants in the treatment of the edentulous jaw Experience from a 10-year period", 16, pp.1~132 (1977), Brnemark PI
- "The long-term efficacy of currently used dental implants:A review and proposed criteria of success", 1, pp.11~25 (1986)
- "Dental implants:A review", 63, pp.859~70 (1992)
- "Fixture design and overload influence marginal bone loss and fixture success in the Brnemark system", 3, pp.104~111 (1992)
- "Loss of osseointegration caused by occlusal load of oral implants", 7, pp.143~152 (1996)
- "The microbiota associated with successful or failing osseointe- grated titanium implants", 2, pp.145~151 (1987)
- "Microbiologic characterization of ligature induced peri-implantitis in the micro- swine model", 62, pp.548~553 (1991)
- "The diagnosis and treatment of peri-implantitis", 17, pp.63~76 (1998)
- "Treatment of peri-implant infections:a literature review", 6, pp.467~85 (2003)
- "Differential diagnosis and treatment strategies for biologic compli- cations and failing oral implants:a review of the literature", 4, pp.473~90 (1999)
- "Experimentally induced peri-implan- titis:a review of different treatment methods described in the literature", 4, pp.533~44 (2000)
- "Chemical treatment of machined titanium sur- faces.An in vitro study", 3, pp.204~11 (1999)
- "Effects of various prophylactic treatments on titanium", 4, pp.300~11 (1989)
- "Detoxification of endotoxin conta- minated titanium and hydroxyapatite- coated surfaces utilizing various chemo- therapeutic and mechanical modalities", 2, pp.154~8 (1992)
- "Contaminated implant surfaces:an in vitro comparison of implant surface coating and treatment modalities for decontamination", 10, pp.942~8 (1994)
- "Lethal photo-sensi- tization for decontamination of implant surfaces in the treatment of peri- implantitis", 2, pp.104~8 (2001)
- "Effects of mino- cycline on fibroblast attachment and spreading", 2, pp.154~9 (1988)
- "How to treat ailing and failing implants", 1, pp.25~33 (1992)
- "Four-year experience with the placement and maintenance of dental implants by dental students", 9, pp.725~731 (1994)
- "Bone regeneration for reintegration in peri- implant destruction", 1, pp.17~28 (1998)
- "The regenerative poten- tial of plaque induced peri-implant bone defects treated by a submerged mem- brane technique:an experimental study", 8, pp.13~18 (1993)
- "Treatment of peri- implantitis using guided bone regenera- tion and bone grafts alone or in combi- nation", 4, pp.474~84 (1995)
- "Treatment of peri-implantitis using guided bone regeneration and bone grafts alone or in combination", pp.168~175 (1997)
- "Guided bone regeneration in the treatment of periimplantitis and replacement of implant components.An experimental study in the dog", 28, pp.258~263 (2001)
- "Re-osseointegration after treatment of peri-implantitis at different implant surfaces.An experimental study in the dog", 6, pp.595~603 (2001)
- "Biological aspects of implant dentistry:Osseointegration", 4, pp.58~73 (1994)
- "Influence of surface characteristics on bone integration of titanium implants.A histomorphometric study in miniature pigs", 7, pp.889~902 (1991)
- "Bone res- ponse to unloaded and loaded titanium implants with a sandblasted and acid- etched surface:a histometric study in the canine mandible", 1, pp.1~11 (1998)
- "The effect of surface roughness on early in vivo plaque colonization on titanium", 6, pp.556~62 (1997)
- "Surface topography of titanium implants", 4th edition, pp.821~828 (2003)
- "Eva- luation of titanium plasma-sprayed and plasma-sprayed hydroxyapatite implants in vivo", 19, pp.4601~6 (2004)
- "Histologic evaluation of bone response to oxidized and turned titanium micro implants in human jawbone", 3, pp.341~8 (2003)
- "HA-coated dental implants:Long-term consequences", 6, pp.33~41 (1992)
- "Anorganic porous bovine-derived bone mineral(Bio-Oss)& ePTFE membrane in the treatment of peri-implantitis in cynomolgus monkeys", 5, pp.535~47 (2003)
- "Scanning electron microscopic evaluation of the effects of an air-abrasive system on dental im- plants:A comparative in vitro study between machined and plasma-sprayed titanium surfaces", 68, pp.1215~1222 (1997)
- "In vitro studies on the effect of cleaning methods on different implant surfaces", 69, pp.857~64 (1998)
- "Micro-morphometric assess- ment of titanium plasma-sprayed coat- ing removal using burs for the treat- ment of peri-implant disease", 2, pp.129~38 (2000)
- "Tetracycline and its derivatives strongly bind to and are released from tooth surface in active form", 54(10), pp.580~585 (1983)
- "Minocycline reduces gingival collagenolytic activity during diabetes", 18, pp.516~526 (1983)
- "The effect of local doxycycline with and without tricalcium phosphate on the regenerative healing potential of perio- dontal osseous defects in dogs", 60, pp.582~590 (1989)
- "Doxycycline-tricalcium phosphate composite graft facilitates osseous healing in advanced periodontal furcation defects", 62, pp.106~115 (1991)
- "Fibroblastic growth and attach- ment on hydroxyapatite-coated titanium surfaces following the use of various detoxification modalities", 1, pp.189~194 (1992)
- "Treatment of the failing implant:case reports", 4, pp.384~95 (1995)
- "Treatment of peri-implantitis:Longitu- dinal clinical and microbiological fin- dings - a case report", 3, pp.247~254 (1999)
- "An XPS and EM evaluation of six chemical and physical techniques for cleaning of contaminated titanium implants", 3, pp.185~94 (1998)
- "염산테트라싸이클린의 적용시간에 따른 임플란트 표면변화에 관한 주사전자현미경적 연구", 3, pp.523~532 (2002)
- "염산테트라싸이클린의 적용시간에 따른 임플란트 표면변화에 관한 주사전자현미경적 연구", 3, pp.523~532 (2002)