본문 바로가기
KERD
논문KCI 등재

A 48-month clinical performance of hybrid ceramic fragment restorations manufactured in CAD/CAM in non-carious cervical lesions: case report

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

From the restorative perspective, various methods are available to prevent the progression of non-carious cervical lesions. Direct, semi-direct, and indirect composite resin techniques and indirect ceramic restorations are commonly recommended. In this context, semi-direct and indirect restoration approaches are increasingly favored, particularly as digital dentistry becomes more prevalent. To illustrate this, we present a case report demonstrating the efficacy of hybrid ceramic fragments fabricated using computer-aided design (CAD)/computer-aided manufacturing (CAM) technology and cemented with resin cement in treating non-carious cervical lesions over a 48-month follow-up period. A 24-year-old male patient sought treatment for aesthetic concerns and dentin hypersensitivity in the cervical region of the lower premolar teeth. Clinical examination confirmed the presence of two non-carious cervical lesions in the buccal region of teeth #44 and #45. The treatment plan involved indirect restoration using CAD/CAM-fabricated hybrid ceramic fragments as a restorative material. After 48 months, the hybrid ceramic material exhibited excellent adaptation and durability provided by the CAD/CAM system. This case underscores the effectiveness of hybrid ceramic fragments in restoring non-carious cervical lesions, highlighting their long-term stability and clinical success.

Abstract

From the restorative perspective, various methods are available to prevent the progression of non-carious cervical lesions. Direct, semi-direct, and indirect composite resin techniques and indirect ceramic restorations are commonly recommended. In this context, semi-direct and indirect restoration approaches are increasingly favored, particularly as digital dentistry becomes more prevalent. To illustrate this, we present a case report demonstrating the efficacy of hybrid ceramic fragments fabricated using computer-aided design (CAD)/computer-aided manufacturing (CAM) technology and cemented with resin cement in treating non-carious cervical lesions over a 48-month follow-up period. A 24-year-old male patient sought treatment for aesthetic concerns and dentin hypersensitivity in the cervical region of the lower premolar teeth. Clinical examination confirmed the presence of two non-carious cervical lesions in the buccal region of teeth #44 and #45. The treatment plan involved indirect restoration using CAD/CAM-fabricated hybrid ceramic fragments as a restorative material. After 48 months, the hybrid ceramic material exhibited excellent adaptation and durability provided by the CAD/CAM system. This case underscores the effectiveness of hybrid ceramic fragments in restoring non-carious cervical lesions, highlighting their long-term stability and clinical success.

참고문헌 (32)

  1. Teixeira DNR, "Prevalence of noncarious cervical lesions among adults : a systematic review", J Dent, 95, pp.103285~ (2020)
  2. Warreth A, "Tooth surface loss : a review of literature", Saudi Dent J, 32, pp.53~60 (2020)
  3. Duangthip D, "Occlusal stress is involved in the formation of non-carious cervical lesions. A systematic review of abfraction", Am J Dent, 30, pp.212~220 (2017)
  4. Yan J, "Low torque is a risk factor for non-carious cervical lesions(NCCLs)in maxillary premolars", Am J Dent, 34, pp.245~249 (2021)
  5. Fahl N Jr, "Direct-indirect class v restorations : a novel approach for treating noncarious cervical lesions", J Esthet Restor Dent, 27, pp.267~284 (2015)
  6. Durán JC, "Multidisciplinary treatment of deep non-carious cervical lesion with a CAD", CAM chairside restoration in combination with periodontal surgery : a 60-month follow-up technique report, 2021, pp.11, 87~92
  7. Staninec M, "Restoration of non-carious cervical lesions with ceramic inlays : a possible model for clinical testing of adhesive cements", Dent Hypotheses, 3, pp.155~158 (2012)
  8. Fathy H, "Clinical performance of resin-matrix ceramic partial coverage restorations : a systematic review", Clin Oral Investig, 26, pp.3807~3822 (2022)
  9. Alharbi A, "Semidirect composite onlay with cavity sealing : a review of clinical procedures", J Esthet Restor Dent, 26, pp.97~106 (2014)
  10. Azarbal A, "Marginal fit comparison of CAD", CAM crowns milled from two different materials, 2018, pp.27, 421~428
  11. de Paris Matos T, "Patient-related outcomes of conventional impression making versus intraoral scanning for prosthetic rehabilitation : a systematic review and meta-analysis", J Prosthet Dent, 130, pp.19~27 (2023)
  12. Joda T, "The complete digital workflow in fixed prosthodontics : a systematic review", BMC Oral Health, 17, pp.124~ (2017)
  13. Brignardello-Petersen R, "There seem to be similar outcomes when restoring noncarious cervical lesions with direct or semidirect techniques after 2 years", J Am Dent Assoc, 151, pp.e4~ (2020)
  14. Caneppele TMF, "A 2-year clinical evaluation of direct and semi-direct resin composite restorations in non-carious cervical lesions : a randomized clinical study", Clin Oral Investig, 24, pp.1321~1331 (2020)
  15. Ekici MA, "Physical characteristics of ceramic", glass-polymer based CAD, J Adv Prosthodont, pp.2019, 11[DOI]
  16. Boing TF, "Are glass-ionomer cement restorations in cervical lesions more long-lasting than resin-based composite resins? A systematic review and meta-analysis", J Adhes Dent, 20, pp.435~452 (2018)
  17. Mahn E, "Meta-analysis of the influence of bonding parameters on the clinical outcome of tooth-colored cervical restorations", J Adhes Dent, 17, pp.391~403 (2015)
  18. Paula AM, "Clinical performance of non-carious cervical restorations restored with the"sandwich technique"and composite resin : a systematic review and meta-analysis", J Adhes Dent, 21, pp.497~508 (2019)
  19. Bustamante-Hernández N, "Clinical behavior of ceramic, hybrid and composite onlays. A systematic review and meta-analysis", Int J Environ Res Public Health, 17, pp.17~ (2020)
  20. Riley DS, "CARE guidelines for case reports : explanation and elaboration document", J Clin Epidemiol, 89, pp.218~235 (2017)
  21. Hickel R, "Revised FDI criteria for evaluating direct and indirect dental restorations-recommendations for its clinical use, interpretation, and reporting", Clin Oral Investig, 27, pp.2573~2592 (2023)
  22. Alvarez-Arenal A, "Non-carious cervical lesions and risk factors : a case-control study", J Oral Rehabil, 46, pp.65~75 (2019)
  23. Coldea A, "Mechanical properties of polymer-infiltrated-ceramic-network materials", Dent Mater, 29, pp.419~426 (2013)
  24. Peumans M, "Clinical effectiveness of contemporary adhesives for the restoration of non-carious cervical lesions. A systematic review", Dent Mater, 30, pp.1089~1103 (2014)
  25. Marchesi G, "Chairside CAD", CAM materials : current trends of clinical uses, 2021, pp.10, 1170~
  26. Andrade ACM, "Optical property stability of light-cured versus precured CAD-CAM composites", Int J Dent, 2022, pp.2011864~ (2022)
  27. Beyabanaki E, "Evaluation of microshear bond strength of four different CAD-CAM polymer-infiltrated ceramic materials after thermocycling", J Prosthodont, 31, pp.623~628 (2022)
  28. Della Bona A, "Characterization of a polymer-infiltrated ceramic-network material", Dent Mater, 30, pp.564~569 (2014)
  29. Motevasselian F, "In vitro evaluation of the effect of different surface treatments of a hybrid ceramic on the microtensile bond strength to a luting resin cement", J Lasers Med Sci, 10, pp.297~303 (2019)
  30. Spitznagel FA, "Polymer-infiltrated ceramic CAD", CAM inlays and partial coverage restorations : 3-year results of a prospective clinical study over 5 years, 2018, pp.22, 1973~1983
  31. Castro EF, "Adhesion, mechanical properties, and microstructure of resin-matrix cad-cam ceramics", J Adhes Dent, 22, pp.421~431 (2020)
  32. Lucsanszky IJR, "Fracture toughness, flexural strength, and flexural modulus of new CAD", CAM resin composite blocks, 2020, pp.29, 34~41

관련 논문AI추천

Effect of dentin roughening and type of composite material on the restoration of non-carious cervical lesions: an in vivo study with 18 months of follow-upGill Gurdeep Singh, Jain Namita, Singla Rakesh, Verma Sanjana대한치과보존학회 · Restorative Dentistry and Endodontics2023 · 제48권 제4호A combined approach to non-carious cervical lesions associated with gingival recession양성은, 이혜진, 진성호대한치과보존학회 · Restorative Dentistry and Endodontics2016 · 제41권 제3호Restorative management using hybrid ceramic of a patient with severe tooth erosion from swimming: a clinical reportChaimongkon Peampring대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제5호Integration of conventional and digital approach in full mouth rehabilitation of a patient with severe tooth wearJeong-Woo Yun, Mee-Kyoung Son, On-Yu Cheon, Su-Min Kim, Yu-Ri Heo치의학연구원 · Oral Biology Research2025 · 제49권 제1호Effect of the type of resin cement on the fracture resistance of chairside CAD-CAM materials after agingDaniel Meneghetti, Júlia Cadorin Facenda, Katia Raquel Weber, Laura Vitória Rizzatto, Márcia Borba, Marielle Di Domênico, Pedro Henrique Corazza대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제3호Comparison of traditional and simplified methods for repairing CAD/CAM feldspathic ceramicsAlessandro Vichi, Chris Louca, Marco Ferrari, Michele Carrabba대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제4호

이 간행물의 다른 논문 (9건)