Application of Bioabsorbable Plates in Orthognathic Surgery
0
조회
0
다운로드
1
인용
0
참고문헌
초록
Abstract
Backgrounds: Though they are considered as reliable devices, titanium plates and screws have limitations due to some potential problems. To overcome these problems, researches on bioabsorbable materials for internal fixation have been continuing. Recently, there are many clinical trials to apply biodegradable internal fixation devices in oral and maxillofacial surgery. The purpose of this study was to evaluate the clinical results of application of bioabsorbable plates and screws in orthognathic surgery. Methods: Fifty-four patients with dentofacial deformity (17 male patients and 37 female patients) were selected in this study. The patients were treated by internal fixation using bioabsorbable plates and 2.4-mm, 2.0-mm pretapped screws (Biosorb FX, Bionix Implants, Inc., Finland). The patients were evaluated for complications during the follow-up period. Results: Five patients (9.3%) experienced complications. All complications in these cases were infection. No other complications related with physical or mechanical properties of bioabsorbable plates were found such as malunion or nonunion, fractures of plates and loosening of screws. All complications were minor and adequately managed with drainage and supportive care with antibiotics coverage. Conclusions: From the results, the use of these fixation systems in orthognathic surgery will provide a promising alternative titanium fixation in appropriate cases.
참고문헌 (19)
- "A ret-rospective analysis of 279 patients with isolated mandibu-lar fractures treated with titanium miniplates", 52, pp.931~935 (1994)
- "Policy of consultant oral and max-illofacial surgeons towards removal of miniplate compo-nents after jaw fracture fixation:pilot study", 37, pp.110~112 (1999)
- "Rigid internal fixation of mandibularfractures.An analysis of 270 fractures treated using theAO", ASIF method, 1992, pp.21, 65~69
- "Comparison of CTimaging artifacts from craniomaxillofacial internal fixationdevices", 92, pp.1227~1232 (1993)
- "Comparison of artifact from craniomaxillo-facial internal fixation devices:magnetic resonance imag-ing", 93, pp.725~731 (1994)
- "Metal release from titanium fixtures during placement inthe mandible:an experimental study", 8, pp.502~511 (1993)
- "Detection of titaniumin human tissues after craniofacial surgery", 99, pp.976~979 (1997)
- "Resorbable plate fixa-tion in pediatric craniofacial surgery", 100, pp.1~7 (1997)
- "Surgical outcomes using bioabsorbable plating systems inpediatric craniofacial surgery", 9, pp.441~444 (1998)
- "sagittal split os-teotomies fixed with biodegradable or titanium screws comparative study of postoperative stability", 93, pp.534~537 (2002)
- "Tissue response to titaniumplates:a transmitted electron microscopic study", 55, pp.322~326 (1997)
- "Fracture reductionusing a biodegradable material,polylactic acid", 29, pp.393~397
- "Biodegradable fracture-fixation devices inmaxillofacial surgery", 22, pp.50~57 (1993)
- "Comparison of absorbable self-reinforced multilayer poly-l-lactide and metallic plates for the fixation of mandibularbody osteotomies:an experimental study in sheep", 50, pp.255~262 (1992)
- "Skeletal stability following mandibular ad-vancement and rigid fixation with polylactide biodegrad-able screws", 27, pp.3~8 (1998)
- "Use of a resorbable fixation systemin orthognathic surgery", 38, pp.335~337 (2000)
- "The use of selfreinforced biodegradable bone plates and screws in orthognathic surgery", 60, pp.59~65 (2002)
- "Biodegradable self-reinforced poly- L", DL-lactide plates and screws in bimaxillary orthognathic surgery:short term skeletal stability and material related failures, 1998, pp.26, 363~372
- "The removal of plates and screws after Le Fort I osteotomy", 56, pp.184~188 (1998)
