A mandibular continuity defect can be repaired using either a prosthetic device or autogenous bone. A titanium reconstruction plate can be used with a localized or vascularized flap over the defect of the mandible. Unfortunately, the plate may fail due to plate exposure, screw loosening, fracture, or infection, and will need to be removed. Plate exposure though the skin or mucosa is one of the main reasons for failure. In the present work, the authors introduced a lingually positioned reconstruction plate fabricated via three-dimensional printed bending support. This custom reconstruction plate can avoid plate re-exposure as well as reduce surgical errors and operation time.

Abstract

A mandibular continuity defect can be repaired using either a prosthetic device or autogenous bone. A titanium reconstruction plate can be used with a localized or vascularized flap over the defect of the mandible. Unfortunately, the plate may fail due to plate exposure, screw loosening, fracture, or infection, and will need to be removed. Plate exposure though the skin or mucosa is one of the main reasons for failure. In the present work, the authors introduced a lingually positioned reconstruction plate fabricated via three-dimensional printed bending support. This custom reconstruction plate can avoid plate re-exposure as well as reduce surgical errors and operation time.

참고문헌 (19)

  1. Spencer KR, "The use of titanium mandibular reconstruction plates in patients with oral cancer", Int J Oral Maxillofac Surg, 28, pp.288~290 (1999)
  2. Christian Lindqvist, "A comparative study on four screw-plate locking systems in sheep: a clinical and radiological study", International Journal of Oral and Maxillofacial Surgery, 30(2), pp.160~166 (2001), Elsevier BV[DOI]
  3. Takahiko Shibahara, "Fracture of mandibular reconstruction plates used after tumor resection", Journal of Oral and Maxillofacial Surgery, 60(2), pp.182~185 (2002), Elsevier BV[DOI]
  4. Akira Katakura, "Material analysis of AO plate fracture cases", Journal of Oral and Maxillofacial Surgery, 62(3), pp.348~352 (2004), Elsevier BV[DOI]
  5. Harald Schöning, "Primary temporary AO plate reconstruction of the mandible", Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology, 86(6), pp.667~672 (1998), Elsevier BV[DOI]
  6. Tobias Ettl, "Feasibility of alloplastic mandibular reconstruction in patients following removal of oral squamous cell carcinoma", Journal of Cranio-Maxillofacial Surgery, 38(5), pp.350~354 (2010), Elsevier BV[DOI]
  7. P.W. Kämmerer, "Local and systemic risk factors influencing the long-term success of angular stable alloplastic reconstruction plates of the mandible", Journal of Cranio-Maxillofacial Surgery, 42(5), pp.e271~e276 (2014), Elsevier BV[DOI]
  8. Liu SP, "Plate related complication after mandibular reconstruction", Zhonghua Kou Qiang Yi Xue Za Zhi, 48, pp.586~590 (2013)
  9. R. E. Nicholson, "Factors Involved in Long- and Short-term Mandibular Plate Exposure", Archives of Otolaryngology - Head and Neck Surgery, 123(2), pp.217~222 (1997), American Medical Association (AMA)[DOI]
  10. Peter Maurer, "Scope and limitations of methods of mandibular reconstruction: a long-term follow-up", British Journal of Oral and Maxillofacial Surgery, 48(2), pp.100~104 (2010), Elsevier BV[DOI]
  11. Fu-chan Wei, "Complications after Reconstruction by Plate and Soft-Tissue Free Flap in Composite Mandibular Defects and Secondary Salvage Reconstruction with Osteocutaneous Flap", Plastic and Reconstructive Surgery, 112(1), pp.37~42 (2003), Ovid Technologies (Wolters Kluwer Health)[DOI]
  12. Martta Martola, "Fracture of titanium plates used for mandibular reconstruction following ablative tumor surgery", Journal of Biomedical Materials Research Part B: Applied Biomaterials, 80B(2), pp.345~352 (2007), Wiley[DOI]
  13. Masaki Azuma, "Mandibular reconstruction using plates prebent to fit rapid prototyping 3-dimensional printing models ameliorates contour deformity", Head & Face Medicine, 10(1) (2014), Springer Science and Business Media LLC[DOI]
  14. Martin I. Salgueiro, "Experience with the Use of Prebent Plates for the Reconstruction of Mandibular Defects", Craniomaxillofacial Trauma & Reconstruction, 3(4), pp.201~208 (2010), SAGE Publications[DOI]
  15. Larry L. Cunningham, "Stereolithographic Modeling Technology Applied to Tumor Resection", Journal of Oral and Maxillofacial Surgery, 63(6), pp.873~878 (2005), Elsevier BV[DOI]
  16. R. Coopman, "Mandibular wing osteotomy: technical modification", British Journal of Oral and Maxillofacial Surgery, 55(6), pp.635~636 (2017), Elsevier BV[DOI]
  17. Harley H. L. Chan, "3D Rapid Prototyping for Otolaryngology—Head and Neck Surgery: Applications in Image-Guidance, Surgical Simulation and Patient-Specific Modeling", PLOS ONE, 10(9), pp.e0136370~ (2015), Public Library of Science (PLoS)[DOI]
  18. Corrado Toro, "Feasibility of preoperative planning using anatomical facsimile models for mandibular reconstruction", Head & Face Medicine, 3(1) (2007), Springer Science and Business Media LLC[DOI]
  19. Daniel Fritz Zweifel, "Are Virtual Planning and Guided Surgery for Head and Neck Reconstruction Economically Viable?", Journal of Oral and Maxillofacial Surgery, 73(1), pp.170~175 (2015), Elsevier BV[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (10건)