초록

Purpose: This study aimed to evaluate the efficacy of simultaneous computed tomography (CT) and quantitative CT (QCT) in patients with osteoporotic hip fracture (OHF) by analyzing the osteoporosis detection rate and physician prescription rate in comparison with those of conventional dual-energy X-ray absorptiometry (DXA). Materials and Methods: This study included consecutive patients older than 65 years who underwent internal fixation or hip arthroplasty for OHF between February and May 2015. The patients were assigned to either the QCT (47 patients) or DXA group (51 patients). The patients in the QCT group underwent QCT with hip CT, whereas those in the DXA group underwent DXA after surgery, before discharge, or in the outpatient clinic. In both groups, the patients received osteoporosis medication according to their QCT or DXA results. The osteoporosis evaluation rate and prescription rate were determined at discharge, postoperative (PO) day 2, PO day 6, and PO week 12 during an outpatient clinic visit. Results: The osteoporosis evaluation rate at PO week 12 was 70.6% (36 of 51 patients) in the DXA group and 100% in the QCT group (P<0.01). The prescription rates of osteoporosis medication at discharge were 70.2% and 29.4% (P<0.001) and the cumulative prescription rates at PO week 12 were 87.2% and 60.8% (P=0.003) in the QCT and DXA groups, respectively. Conclusion: Simultaneous CT and QCT significantly increased the evaluation and prescription rates in patients with OHF and may enable appropriate and consistent prescription of osteoporosis medication, which may eventually lead to patients’ medication compliance.

Abstract

Purpose: This study aimed to evaluate the efficacy of simultaneous computed tomography (CT) and quantitative CT (QCT) in patients with osteoporotic hip fracture (OHF) by analyzing the osteoporosis detection rate and physician prescription rate in comparison with those of conventional dual-energy X-ray absorptiometry (DXA). Materials and Methods: This study included consecutive patients older than 65 years who underwent internal fixation or hip arthroplasty for OHF between February and May 2015. The patients were assigned to either the QCT (47 patients) or DXA group (51 patients). The patients in the QCT group underwent QCT with hip CT, whereas those in the DXA group underwent DXA after surgery, before discharge, or in the outpatient clinic. In both groups, the patients received osteoporosis medication according to their QCT or DXA results. The osteoporosis evaluation rate and prescription rate were determined at discharge, postoperative (PO) day 2, PO day 6, and PO week 12 during an outpatient clinic visit. Results: The osteoporosis evaluation rate at PO week 12 was 70.6% (36 of 51 patients) in the DXA group and 100% in the QCT group (P<0.01). The prescription rates of osteoporosis medication at discharge were 70.2% and 29.4% (P<0.001) and the cumulative prescription rates at PO week 12 were 87.2% and 60.8% (P=0.003) in the QCT and DXA groups, respectively. Conclusion: Simultaneous CT and QCT significantly increased the evaluation and prescription rates in patients with OHF and may enable appropriate and consistent prescription of osteoporosis medication, which may eventually lead to patients’ medication compliance.

참고문헌 (34)

  1. Watts NB, "National Osteoporosis Foundation 2008 Clinician’s Guide to Prevention and Treatment of Osteoporosis and the World Health Organization Fracture Risk Assessment Tool(FRAX) : what they mean to the bone densitometrist and bone technologist", J Clin Densitom, 11, pp.473~477 (2008)
  2. Cummings SR, "Epidemiology of osteoporosis and osteoporotic fractures", Epidemiol Rev, 7, pp.178~208 (1985)
  3. Cooper C, "Population-based study of survival after osteoporotic fractures", Am J Epidemiol, 137, pp.1001~1005 (1993)
  4. Lyles KW, "Zoledronic acid and clinical fractures and mortality after hip fracture", N Engl J Med, 357, pp.1799~1809 (2007)
  5. Klotzbuecher CM, "Patients with prior fractures have an increased risk of future fractures : a summary of the literature and statistical synthesis", J Bone Miner Res, 15, pp.721~739 (2000)
  6. Schürch MA, "A prospective study on socioeconomic aspects of fracture of the proximal femur", J Bone Miner Res, 11, pp.1935~1942 (1996)
  7. Trombetti A, "Survival and potential years of life lost after hip fracture in men and age-matched women", Osteoporos Int, 13, pp.731~737 (2002)
  8. Wolinsky FD, "The effect of hip fracture on mortality, hospitalization, and functional status : a prospective study", Am J Public Health, 87, pp.398~403 (1997)
  9. Andrade SE, "Low frequency of treatment of osteoporosis among postmenopausal women following a fracture", Arch Intern Med, 163, pp.2052~2057 (2003)
  10. Gong HS, "Patients with wrist fractures are less likely to be evaluated and managed for osteoporosis", J Bone Joint Surg Am, 91, pp.2376~2380 (2009)
  11. Giangregorio L, "Fragility fractures and the osteoporosis care gap : an international phenomenon", Semin Arthritis Rheum, 35, pp.293~305 (2006)
  12. Torgerson DJ, "Prescribing by general practitioners after an osteoporotic fracture", Ann Rheum Dis, 57, pp.378~379 (1998)
  13. Kamel HK, "Failure to diagnose and treat osteoporosis in elderly patients hospitalized with hip fracture", Am J Med, 109, pp.326~328 (2000)
  14. Melton LJ 3rd, "Perspective. How many women have osteoporosis?", J Bone Miner Res, 7, pp.1005~1010 (1992)
  15. Freedman KB, "Treatment of osteoporosis: are physicians missing an opportunity?", J Bone Joint Surg Am, 82-A, pp.1063~1070 (2000)
  16. Miller PD, "Bone densitometry : the best way to detect osteoporosis and to monitor therapy", J Clin Endocrinol Metab, 84, pp.1867~1871 (1999)
  17. Borders J, "Quantitative dual-energy radiographic absorptiometry of the lumbar spine : in vivo comparison with dual-photon absorptiometry", Radiology, 170, pp.129~131 (1989)
  18. Sartoris DJ, "Current and innovative methods for noninvasive bone densitometry", Radiol Clin North Am, 28, pp.257~278 (1990)
  19. Wahner HW, "Comparison of dual-energy x-ray absorptiometry and dual photon absorptiometry for bone mineral measurements of the lumbar spine", Mayo Clin Proc, 63, pp.1075~1084 (1988)
  20. Crilly RG, "Comparison of hip fracture and osteoporosis medication prescription rates across Canadian provinces", Osteoporos Int, 25, pp.205~210 (2014)
  21. Grover M, "Increased osteoporosis screening rates associated with the provision of a preventive health examination", J Am Board Fam Med, 22, pp.655~662 (2009)
  22. Kalender WA., "Effective dose values in bone mineral measurements by photon absorptiometry and computed tomography", Osteoporos Int, 2, pp.82~87 (1992)
  23. Huda W, "Patient doses in bone mineral densitometry", Br J Radiol, 69, pp.422~425 (1996)
  24. Kalender WA, "Technical approaches to the optimisation of CT", Phys Med, 24, pp.71~79 (2008)
  25. Damilakis J, "Radiation exposure in X-ray-based imaging techniques used in osteoporosis", Eur Radiol, 20, pp.2707~2714 (2010)
  26. Autier P, "Costs induced by hip fractures: a prospective controlled study in Belgium. Belgian Hip Fracture Study Group", Osteoporos Int, 11, pp.373~380 (2000)
  27. Haentjens P, "The economic cost of hip fractures among elderly women. A one-year, prospective, observational cohort study with matched-pair analysis. Belgian Hip Fracture Study Group", J Bone Joint Surg Am, 83-A, pp.493~500 (2001)
  28. Sambrook P, "Osteoporosis", Lancet, 367, pp.2010~2018 (2006)
  29. Zethraeus N, "Models for assessing the cost-effectiveness of the treatment and prevention of osteoporosis", Osteoporos Int, 13, pp.841~857 (2002)
  30. Boonen S, "Functional outcome and quality of life following hip fracture in elderly women : a prospective controlled study", Osteoporos Int, 15, pp.87~94 (2004)
  31. Li C, "Long-term effect of incadronate disodium(YM-175)on fracture healing of femoral shaft in growing rats", J Bone Miner Res, 16, pp.429~436 (2001)
  32. Cao Y, "Raloxifene, estrogen, and alendronate affect the processes of fracture repair differently in ovariectomized rats", J Bone Miner Res, 17, pp.2237~2246 (2002)
  33. Odvina CV, "Severely suppressed bone turnover : a potential complication of alendronate therapy", J Clin Endocrinol Metab, 90, pp.1294~1301 (2005)
  34. Rozental TD, "Improving evaluation and treatment for osteoporosis following distal radial fractures. A prospective randomized intervention", J Bone Joint Surg Am, 90, pp.953~961 (2008)

관련 논문AI추천