경구기관삽관 시 기관삽관 기구에 따른 경추 움직임 비교: 마네킨 예비 연구
Comparison of Cervical Spine Movement by Airway Equipment during Orotracheal Intubation: A Manikin Pilot Study
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background: In patients with limited cervical spine movement, equipment for orotracheal intubation should achieve sufficient laryngeal exposure with the least cervical spine movement. This study was designed to compare movement of the cervical spine during the orotracheal intubation with various intubating equipment. Methods: Twelve emergency physicians & residents with a total experience of >50 cases of endotracheal intubation in two emergency centers were assigned to perform orotracheal intubation with four different airway devices,including the Macintosh laryngoscope (ML), DCI video laryngoscope (DCI), Airway Scope (AWS) and Levitan Scope (LS), using the same manikin (AmbuⓇ airway management trainer) in random sequences. Movement of the C-spine was examined by measuring the angle formed by two lines which are parallel to the anterior surface of the C2 and C7 vertebrae bodies. The angle was measured when Cormack-Lehane grade II glottis exposure was achieved during intubation. Results: Mean cervical spine movements were 37.6 ± 9.2o, 32.2 ± 14.2o, 32.2 ± 6.45o and 17.4 ± 10.0o with the ML, DCI (p = 0.347), AWS (p = 0.094), and LS (p < 0.001), respectively, compared to that of ML. Cervical spine movement by LS was 54% less than that by ML. LS produced less cervical spine movement in comparison to DCI (p = 0.013) and AWS (p = 0.001). Conclusions: The Levitan Scope produced less movement of the cervical spine when compared to the Macintosh laryngoscope, DCI video-laryngoscope and Airway Scope during orotracheal intubation in a single airway training manikin model.
Abstract
Background: In patients with limited cervical spine movement, equipment for orotracheal intubation should achieve sufficient laryngeal exposure with the least cervical spine movement. This study was designed to compare movement of the cervical spine during the orotracheal intubation with various intubating equipment. Methods: Twelve emergency physicians & residents with a total experience of >50 cases of endotracheal intubation in two emergency centers were assigned to perform orotracheal intubation with four different airway devices,including the Macintosh laryngoscope (ML), DCI video laryngoscope (DCI), Airway Scope (AWS) and Levitan Scope (LS), using the same manikin (AmbuⓇ airway management trainer) in random sequences. Movement of the C-spine was examined by measuring the angle formed by two lines which are parallel to the anterior surface of the C2 and C7 vertebrae bodies. The angle was measured when Cormack-Lehane grade II glottis exposure was achieved during intubation. Results: Mean cervical spine movements were 37.6 ± 9.2o, 32.2 ± 14.2o, 32.2 ± 6.45o and 17.4 ± 10.0o with the ML, DCI (p = 0.347), AWS (p = 0.094), and LS (p < 0.001), respectively, compared to that of ML. Cervical spine movement by LS was 54% less than that by ML. LS produced less cervical spine movement in comparison to DCI (p = 0.013) and AWS (p = 0.001). Conclusions: The Levitan Scope produced less movement of the cervical spine when compared to the Macintosh laryngoscope, DCI video-laryngoscope and Airway Scope during orotracheal intubation in a single airway training manikin model.
참고문헌 (15)
- George Kovacs, "Airway Management in Emergencies. 1st ed", pp.56~59 (2008), McGraw-Hill Companies
- Byhahn C, "Tracheal intubation using the mobile C-MAC video laryngoscope or direct laryngoscopy for patients with a simulated difficult airway", Minerva Anestesiol, 76, pp.577~583 (2010)
- Aoi Y, "Airway scope versus macintosh laryngoscope in patients with simulated limitation of neck movements", J Trauma, 69, pp.838~842 (2010)
- Vlatten A, "A comparison of the STORZ video laryngoscope and standard direct laryngoscopy for intubation in the Pediatric airway--a randomized clinical trial", Paediatr Anaesth, 19, pp.1102~1107 (2009)
- Niforopoulou P, "Video-laryngoscopes in the adult airway management: a topical review of the literature", Acta Anaesthesiol Scand, 54, pp.1050~1061 (2010)
- Greenland KB, "Comparison of the Levitan FPS Scope and the single-use bougie for simulated difficult intubation in anaesthetised patients", Anaesthesia, 62, pp.509~515 (2007)
- Manoach S, "Manual in-line stabilization for acute airway management of suspected cervical spine injury: historical review and current questions", Ann Emerg Med, 50, pp.236~245 (2007)
- Turkstra TP, "Cervical spine motion: a fluoroscopic comparison during intubation with lighted stylet, GlideScope, and Macintosh laryngoscope", Anesth Analg, 101, pp.910~915 (2005)
- Turkstra TP, "Cervical spine motion: a fluoroscopic comparison of Shikani Optical Stylet vs Macintosh laryngoscope", Can J Anaesth, 54, pp.441~447 (2007)
- Rudolph C, "Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope", Anaesthesia, 60, pp.668~672 (2005)
- Enomoto Y, "Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: a randomized comparative study", Br J Anaesth, 100, pp.544~548 (2008)
- Hirabayashi Y, "Cervical spine movement during laryngoscopy using the Airway Scope compared with the Macintosh laryngoscope", Anaesthesia, 62, pp.1050~1055 (2007)
- Maruyama K, "Randomized cross-over comparison of cervical-spine motion with the AirWay Scope or Macintosh laryngoscope with in-line stabilization: a video-fluoroscopic study", Br J Anaesth, 101, pp.563~567 (2008)
- Malik MA, "Comparison of Macintosh, Truview EVO2, Glidescope, and Airwayscope laryngoscope use in patients with cervical spine immobilization", Br J Anaesth, 101, pp.723~730 (2008)
- Cooper RM, "Rigid and Semirigid fiberoptic and video laryngoscopy and intubation. In: Management of the difficult and failed airway. 1st ed", pp.152~153 (2008), McGraw-Hill Companies