Superior Gluteal Artery Injury during Percutaneous Iliosacral Screw Fixation: A Case Report

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Percutaneous iliosacral screw fixation is commonly practiced to treat unstable posterior pelvic ring injuries. The number of reported cases of iatrogenic complications is increasing. We present a case of superior gluteal artery injury during bilateral percutaneous iliosacral screw fixation in a patient with sacral fracture of spino-pelvic dissociation. This complication was managed by arterial embolization. We discussed the cause, prevention and treatment of arterial injury along with a review of literature.

Abstract

Percutaneous iliosacral screw fixation is commonly practiced to treat unstable posterior pelvic ring injuries. The number of reported cases of iatrogenic complications is increasing. We present a case of superior gluteal artery injury during bilateral percutaneous iliosacral screw fixation in a patient with sacral fracture of spino-pelvic dissociation. This complication was managed by arterial embolization. We discussed the cause, prevention and treatment of arterial injury along with a review of literature.

참고문헌 (9)

  1. Matta JM, "Internal fixation of pelvic ring fractures", Clin Orthop Relat Res, 242, pp.83~97 (1989)
  2. Routt ML Jr, "Early results of percutaneous iliosacral screws placed with the patient in the supine position", J Orthop Trauma, 9, pp.207~214 (1995)
  3. Rysavy M, "Iliosacral screw fixation of the unstable pelvic ring injuries", Acta Chir Orthop Traumatol Cech, 77, pp.209~214 (2010)
  4. Templeman D, "Proximity of iliosacral screws to neurovascular structures after internal fixation", Clin Orthop Relat Res, 329, pp.194~198 (1996)
  5. Collinge C, "Risks to the superior gluteal neurovascular bundle during percutaneous iliosacral screw insertion : an anatomical cadaver study", J Orthop Trauma, 19, pp.96~101 (2005)
  6. Altman DT, "Superior gluteal artery injury during iliosacral screw placement", J Orthop Trauma, 13, pp.220~227 (1999)
  7. Marmor M, "Superior gluteal artery injury during iliosacral screw placement due to aberrant anatomy", Orthopedics, 33, pp.117~120 (2010)
  8. Stephen DJ, "Pseudoaneurysm of the superior gluteal arterial system : an unusual cause of pain after a pelvic fracture", J Trauma, 43, pp.146~149 (1997)
  9. Maled I, "Pseudoaneurysm of the superior gluteal artery during iliosacral screw fixation", Acta Orthop Belg, 73, pp.544~547 (2007)