Revision Total Hip Arthroplasty for Spongy Metal Lübeck Hip Prosthesis with Repeated Stem Fracture and Periprosthetic Femur Fractures: A Case Report
4
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
The fully porous structure of the Lübeck prosthesis is designed to closely resemble cancellous bone. Several studies have reported ‘good’ to ‘excellent’ mid- to long-term results for use of the Lübeck, but stem fractures have been reported as a complication. We report on the case of an 85-year-old patient who underwent total hip arthroplasty (THA) using the Lübeck more than 25 years ago who underwent revision surgery for management of two periprosthetic femoral fractures and a stem fracture. A subtrochanteric fracture and a fracture of the stem were observed on radiographs, and a radiolucent line was observed in the proximal portion of the stem and a well-fixed distal portion was observed. Revision THA using a proximal femoral replacement stem and resection of the proximal femur has been proven as an effective procedure for treatment of an elderly patient with a fractured Lübeck stem with a well-fixed distal stem.
Abstract
The fully porous structure of the Lübeck prosthesis is designed to closely resemble cancellous bone. Several studies have reported ‘good’ to ‘excellent’ mid- to long-term results for use of the Lübeck, but stem fractures have been reported as a complication. We report on the case of an 85-year-old patient who underwent total hip arthroplasty (THA) using the Lübeck more than 25 years ago who underwent revision surgery for management of two periprosthetic femoral fractures and a stem fracture. A subtrochanteric fracture and a fracture of the stem were observed on radiographs, and a radiolucent line was observed in the proximal portion of the stem and a well-fixed distal portion was observed. Revision THA using a proximal femoral replacement stem and resection of the proximal femur has been proven as an effective procedure for treatment of an elderly patient with a fractured Lübeck stem with a well-fixed distal stem.
참고문헌 (19)
- Khanuja HS, "Cementless femoral fixation in total hip arthroplasty", J Bone Joint Surg Am, 93, pp.500~509 (2011)[DOI]
- Pilliar RM, "Observations on the effect of movement on bone ingrowth into porous-surfaced implants", Clin Orthop Relat Res, (208), pp.108~113 (1986)
- Bobyn JD, "The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone", Clin Orthop Relat Res, (150), pp.263~270 (1980)[DOI]
- Mittelmeier W, "Comparative static biomechanical studies of tripod surface structures of cementless endoprostheses", Z Orthop Ihre Grenzgeb, 137, pp.122~128 (1999)[DOI]
- Hacking SA, "Relative contributions of chemistry and topography to the osseointegration of hydroxyapatite coatings", Clin Orthop Relat Res, (405), pp.24~38 (2002)[DOI]
- Søballe K, "Tissue ingrowth into titanium and hydroxyapatitecoated implants during stable and unstable mechanical conditions", J Orthop Res, 10, pp.285~299 (1992)[DOI]
- Bobyn JD, "The effect of porous surface configuration on the tensile strength of fixation of implants by bone ingrowth", Clin Orthop Relat Res, (149), pp.291~298 (1980)[DOI]
- "Orthopade", 1997, 117~124, 10.1007[DOI]
- Gerdesmeyer L, "19 years outcome after cementless total hip arthroplasty with spongy metal structured implants in patients younger than 65years", BMC Musculoskelet Disord, 17, pp.429~ (2016)[DOI]
- Plötz W, "Cementless prosthesis of the hip joint with"spongy metal"surface. A prospective study", Arch Orthop Trauma Surg, 111, pp.102~109 (1992)[DOI]
- Sielewicz M, "A five year follow-up of 605cases of the MCCL(metal-cancellous cementless Lübeck)total hip prosthesis", Ital J Orthop Traumatol, 15, pp.433~443 (1989)
- Sugano N, "Spongy metal Lübeck hip prostheses for osteoarthritis secondary to hip dysplasia. A 2-6-year follow-up study", J Arthroplasty, 9, pp.253~262 (1994)[DOI]
- Matsui M, "The Metal-Cancellous Cementless Lübeck total hip arthroplasty. Five-to-nine-year results", J Bone Joint Surg Br, 80, pp.404~410 (1998)[DOI]
- Götze C, "Long-term results of the metal-cancellous cementless Lübeck total hip arthroplasty : a critical review at 12. 8years", Arch Orthop Trauma Surg, 126, pp.28~35 (2006)[DOI]
- Fujihara Y, "Use of the G-guide for measuring stem antetorsion during total hip arthroplasty", Orthopedics, 39, pp.e271~e275 (2016)[DOI]
- Lenze F, "A 30-year single-center experience of cementless total hip arthroplasty with spongy metal structured implants : a follow-up of a previous report", In Vivo, 33, pp.833~838 (2019)[DOI]
- Kishida Y, "Stem fracture of the cementless spongy metal Lübeck hip prosthesis", J Arthroplasty, 17, pp.1021~1027 (2002)[DOI]
- Nagoya S, "Successful reimplantation surgery after extraction of well-fixed cementless stems by femoral longitudinal split procedure", Arthroplast Today, 6, pp.123~128 (2020)[DOI]
- Diaz-Dilernia F, "Impaction bone grafting or uncemented modular stems for the treatment of type B3 periprosthetic femoral fractures? A complication rate analysis", J Arthroplasty, 34, pp.2051~2057 (2019)[DOI]
