소아청소년 환자에서 Minitube appliance와 가는 NiTi wire를 이용한 약력 교정: 증례보고
Light-force orthodontic treatment using the minitube appliance and thin NiTi wire in children and adolescent: Case reports
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
The mini-tube appliance (MTA) is comfortable and advantageous in terms of aesthetics and oral hygiene compared to conventional brackets. By using 0.012 inch Thermoactive (TA) NiTi wires, the frictional resistance is low. So treatment are possible within a short period and there are fewer side effects, such as root resorption. Light-force orthodontic treatment using MTA and thin TA NiTi wire is a suitable treatment method in pediatric dentistry, considering the increasing aesthetic needs and the nature of pediatric patients. By using the MTA and thin TA NiTi wire, the cases reported here have led to positive treatment outcomes in minor orthodontic treatment for the anterior teeth crowding and retreatment following relapse after orthodontic treatment.
Abstract
The mini-tube appliance (MTA) is comfortable and advantageous in terms of aesthetics and oral hygiene compared to conventional brackets. By using 0.012 inch Thermoactive (TA) NiTi wires, the frictional resistance is low. So treatment are possible within a short period and there are fewer side effects, such as root resorption. Light-force orthodontic treatment using MTA and thin TA NiTi wire is a suitable treatment method in pediatric dentistry, considering the increasing aesthetic needs and the nature of pediatric patients. By using the MTA and thin TA NiTi wire, the cases reported here have led to positive treatment outcomes in minor orthodontic treatment for the anterior teeth crowding and retreatment following relapse after orthodontic treatment.
참고문헌 (16)
- 최은정, "최근 5년간(2000-2005) 서울대학교치과병원 소아치과의진료현황 변화 및 신환분포에 대한 조사", 대한소아치과학회지, 33(4), pp.673~677 (2006), 대한소아치과학회
- 손유진, "최근 8년간(2001-2008) 서울대학교치과병원 소아치과의 진료현황 및 수익분포 변화에 대한 조사", 대한소아치과학회지, 37(1), pp.97~101 (2010), 대한소아치과학회
- Baik HS, "Contemporary removable Orthodontics", pp.15~ (2003), Daehannarae publishing
- 김은지, "성인 환자의 전악 교정 치료에서 심미적인 심플-튜브의 활용", 대한치과교정학회 임상저널, 10(4), pp.264~273 (2020), 대한치과교정학회[DOI]
- Seo-Rin Jeong, "Treatment of Class I crowding using simple tubes bonded with customized resin coverings: A case report", 대한치과교정학회지, 49(2), pp.116~123 (2019), 대한치과교정학회[DOI]
- 황현식, "성인 전치부 부분교정을 위한 새로운 교정장치 MTA의 이용", 대한치과의사협회지, 49(7), pp.398~409 (2011), 대한치과의사협회[DOI]
- 김소영, "Forced eruption with customized resin tube appliance", Oral Biology Research, 42(1), pp.45~52 (2018), 치의학연구원[DOI]
- Johnson JE, "The twin-wire appliance", Am J Orthod, 24, pp.303~327 (1938)
- Johnson JE, "The construction and manipulation on the twinwire mechanism", Am J Orthod Oral Surg, 27, pp.202~215 (1941)
- Park SH, "Correction of palatally displaced maxillary lateral incisors using a tube system", J Clin Orthod, 42, pp.461~465 (2008)
- Turkkahraman H, "Archwire ligation techniques, microbial colonization, and periodontal status in orthodontically treated patients", Angle Orthod, 75, pp.231~236 (2005)
- Nam JS, "Easy entire orthodontic treatment with Itube", pp.13~16 (2016), Myungmun publishing
- Hwang HS, "Use of a minitube appliance in periodontally compromised adult patients with severely displaced incisors", J Clin orthod, 50, pp.533~542 (2016)
- Proffit WR, "Contemporary orthodontics", pp.292~294, Daehannarae publishing
- Park YC, "Contemporary lingual orthodontics", pp.300~305 (2015), Daehannarae publishing
- Hwang HS, "Orthodontic management of horizontal and vertical space problems in prosthodontics", J Korean Acad Prosthodont, 38, pp.412~420 (2000)
