High Efficiency Binding Aptamers for a Wide Range of Bacterial Sepsis Agents
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Sepsis is a major health problem worldwide, with an extremely high rate of morbidity and mortality, partly due to delayed diagnosis during early disease. Currently, sepsis diagnosis requires bacterial culturing of blood samples over several days, whereas PCR-based molecular diagnosis methods are faster but lack sensitivity. The use of biosensors containing nucleic acid aptamers that bind targets with high affinity and specificity could accelerate sepsis diagnosis. Previously, we used the systematic evolution of ligands by exponential enrichment technique to develop the aptamers Antibac1 and Antibac2, targeting the ubiquitous bacterial peptidoglycan. Here, we show that these aptamers bind to four gram-positive and seven gram-negative bacterial sepsis agents with high binding efficiency. Thus, these aptamers could be used in combination as biological recognition elements in the development of biosensors that are an alternative to rapid bacteria detection, since they could provide culture and amplification-free tests for rapid clinical sepsis diagnosis.
Abstract
Sepsis is a major health problem worldwide, with an extremely high rate of morbidity and mortality, partly due to delayed diagnosis during early disease. Currently, sepsis diagnosis requires bacterial culturing of blood samples over several days, whereas PCR-based molecular diagnosis methods are faster but lack sensitivity. The use of biosensors containing nucleic acid aptamers that bind targets with high affinity and specificity could accelerate sepsis diagnosis. Previously, we used the systematic evolution of ligands by exponential enrichment technique to develop the aptamers Antibac1 and Antibac2, targeting the ubiquitous bacterial peptidoglycan. Here, we show that these aptamers bind to four gram-positive and seven gram-negative bacterial sepsis agents with high binding efficiency. Thus, these aptamers could be used in combination as biological recognition elements in the development of biosensors that are an alternative to rapid bacteria detection, since they could provide culture and amplification-free tests for rapid clinical sepsis diagnosis.
참고문헌 (31)
- Dellinger RP, "Surviving Sepsis Campaign:International guidelines for management of severe sepsis and septic shock: 2008", Crit. Care Med, 36, pp.296~327 (2008)
- Angus DC, "Severe sepsis and septic shock", N. Engl. J. Med, 369, pp.840~851 (2013)
- Angus DC, "Epidemiology of severe sepsis in the United States: analysis of incidence, outcome, and associated costs of care", Crit. Care Med, 29, pp.1303~1310 (2001)
- Boedicker JQ, "Detecting bacteria and determining their susceptibility to antibiotics by stochastic confinement in nanoliter droplets using plugbased microfluidics", Lab. Chip, 8, pp.1265~1272 (2008)
- Kaufman D, "Clinical microbiologv of bacterial and fungal sepsis in very-low-birth-weight infants", Clin. Microbiol. Rev, 17, pp.638~643 (2004)
- Lee A, "Detection of bloodstream infections in adults: how many blood cultures are needed?", J. Clin. Microbiol, 47, pp.3546~3548 (2007)
- Lazcka O, "Pathogen detection: a perspective of traditional methods and biosensors", Biosens. Bioelectron, 22, pp.1205~1217 (2007)
- Su L, "Microbial biosensors: a review", Biosens. Bioelectron, 26, pp.1788~1799 (2011)
- Tuerk C, "Systematic evolution of ligands by exponential enrichment: RNA ligands to bacteriophage T4DNA polymerase", Science, 249, pp.505~510 (1990)
- Ellington AD, "In vitro selection of RNA molecules that bind specific ligands", Nature, 346, pp.818~822 (1990)
- Ferreira IM, "Selection of peptidoglycan-specific aptamers for bacterial cells identification", Appl. Biochem. Biotechnol, 174, pp.2548~2556 (2014)
- Schleifer KH, "Peptidoglycan. Types of bacterial cell walls and their taxonomic implications", Bacteriol. Rev, 36, pp.407~477 (1972)
- Marton S, "Isolation of an aptamer that binds specifically to E. coli", PLoS One, 11, pp.e0153637~ (2016)
- Livak KJ, "Analysis of relative gene expression data using real time quantitative PCR and the 2ΔCT method", Methods, 25, pp.402~408 (2001)
- Torres-Chavolla E, "Aptasensors for detection of microbial and viral pathogens", Biosens. Bioelectron, 26, pp.3175~3182 (2009)
- Amaya E, "Extended-spectrum β-lactamase-producing Klebsiella pneumoniae in a neonatal intensive care unit in Leon, Nicaragua", Int. J. Antimicrob. Agents, 33, pp.386~387 (2009)
- Gray J, "An outbreak of Klebsiella pneumoniae late-onset sepsis in a neonatal intensive care unit in Guatemala", Am. J. Infect. Control, 40, pp.516~520 (2012)
- Zakariya BP, "Risk factors and outcome of Klebsiella pneumoniae sepsis among newborns", Curr. Pediatr. Res, 16, pp.115~118 (2012)
- Micek ST, "Pseudomonas aeruginosa bloodstream infection:importance of appropriate initial antimicrobial treatment", Antimicrob. Agents Chemother, 49, pp.1306~1311 (2005)
- Richards MJ, "Nosocomial infections in medical intensive care units in the United States: National Nosocomial Infections Surveillance System", Crit. Care Med, 27, pp.887~892 (1999)
- Lahmer T, "Acinetobacter baumannii sepsis is fatal in medical intensive care unit patients: six cases and review of literature", Anaesth. Intensive Care, 42, pp.541~684 (2014)
- Patrick M, "Severe Acinetobacter baumannii sepsis is associated with elevation of Pentraxin 3", Infect. Immun, 82, pp.3910~3918 (2014)
- De Pedro M, "Structural constraints and dynamics of bacterial cell wall architecture", Front. Microbiol, 6, pp.449~ (2015)
- Xiao Z, "Cellspecific internalization study of an aptamer from whole cell selection", Chem. Eur. J, 14, pp.1769~1775 (2008)
- Raetz CR, "Lipopolysaccharide endotoxins", Annu. Rev. Biochem, 71, pp.635~700 (2002)
- Vollmer W., "Structural variation in the glycan strands of bacterial peptidoglycan", FEMS Microbiol, 32, pp.287~306 (2008)
- Bayer ME, "Zones of membrane adhesion in the cryofixed envelope of Escherichia coli", J. Struct. Biol, 107, pp.268~280 (1991)
- Keefe AD, "Aptamers as therapeutics", Nat. Rev. Drug Discov, 9, pp.537~550 (2010)
- Lee JF, "Aptamer therapeutics advance", Curr. Opin. Chem. Biol, 10, pp.282~289 (2006)
- Chang YC, "Rapid single cell detection of Staphylococcus aureus by aptamer-conjugated gold nanoparticles", Sci. Rep, 3, pp.1863~ (2013)
- Song S, "Aptamer-based biosensors", Trends Anal. Chem, 27, pp.108~117 (2008)
