본문 바로가기
KERD
논문KCI 등재

Awareness during general anesthesia despite simultaneous bispectral index and end-tidal anesthetic gas concentration monitoring

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류의학일반

초록

Awareness during general anesthesia occurs in approximately 0.1–0.2% of cases; nevertheless, particular attention is required because it can lead to critical complications including insomnia, depression, anxiety, and post-traumatic stress disorder. To prevent these complications, bispectral index (BIS) and end-tidal anesthetic gas (ETAG) concentration monitoring are commonly used to examine patient consciousness during surgery. In the present case, an 80-year-old man was scheduled for total gastrectomy. Anesthesia was maintained using desflurane 4.0–5.0% vol, oxygen, and nitrous oxide. The authors simultaneously monitored BIS, which was maintained between 37 and 43, and ETAG, which was maintained between 0.9 and 1.2 minimum alveolar concentration (MAC). After the operation, however, the authors were surprised to learn that the patient complained of awareness during anesthesia. Although BIS and ETAG concentration monitoring are useful in preventing awareness during anesthesia, they cannot be completely trusted. Even though BIS was maintained at approximately 40 and ETAG at 0.7–1.3 MAC, awareness during anesthesia occurred.

Abstract

Awareness during general anesthesia occurs in approximately 0.1–0.2% of cases; nevertheless, particular attention is required because it can lead to critical complications including insomnia, depression, anxiety, and post-traumatic stress disorder. To prevent these complications, bispectral index (BIS) and end-tidal anesthetic gas (ETAG) concentration monitoring are commonly used to examine patient consciousness during surgery. In the present case, an 80-year-old man was scheduled for total gastrectomy. Anesthesia was maintained using desflurane 4.0–5.0% vol, oxygen, and nitrous oxide. The authors simultaneously monitored BIS, which was maintained between 37 and 43, and ETAG, which was maintained between 0.9 and 1.2 minimum alveolar concentration (MAC). After the operation, however, the authors were surprised to learn that the patient complained of awareness during anesthesia. Although BIS and ETAG concentration monitoring are useful in preventing awareness during anesthesia, they cannot be completely trusted. Even though BIS was maintained at approximately 40 and ETAG at 0.7–1.3 MAC, awareness during anesthesia occurred.

참고문헌 (14)

  1. Ghoneim MM, "Awareness during anesthesia", Anesthesiology, 92, pp.597~602 (2000)
  2. Sebel PS, "The incidence of awareness during anesthesia: a multicenter United States study", Anesth Analg, 99, pp.833~839 (2004)
  3. Lennmarken C, "Victims of awareness", Acta Anaesthesiol Scand, 46, pp.229~231 (2002)
  4. Avidan MS, "Prevention of intraoperative awareness in a high-risk surgical population", N Engl J Med, 365, pp.591~600 (2011)
  5. Pollard RJ, "Intraoperative awareness in a regional medical system: a review of 3 years' data", Anesthesiology, 106, pp.269~274 (2007)
  6. Errando CL, "Awareness with recall during general anaesthesia: a prospective observational evaluation of 4001 patients", Br J Anaesth, 101, pp.178~185 (2008)
  7. Pandit JJ, "The 5th National Audit Project (NAP5) on accidental awareness during general anaesthesia: summary of main findings and risk factors", Anaesthesia, 69, pp.1089~1101 (2014)
  8. Song D, "Titration of volatile anesthetics using bispectral index facilitates recovery after ambulatory anesthesia", Anesthesiology, 87, pp.842~848 (1997)
  9. Rampil IJ, "A primer for EEG signal processing in anesthesia", Anesthesiology, 89, pp.980~1002 (1998)
  10. Dahaba AA, "Different conditions that could result in the bispectral index indicating an incorrect hypnotic state", Anesth Analg, 101, pp.765~773 (2005)
  11. Schneider G, "Bispectral Index (BIS) may not predict awareness reaction to intubation in surgical patients", J Neurosurg Anesthesiol, 14, pp.7~11 (2002)
  12. Myles PS, "Bispectral index monitoring to prevent awareness during anaesthesia: the B-Aware randomised controlled trial", Lancet, 363, pp.1757~1763 (2004)
  13. McLeskey CH, "Awareness during anesthesia", Can J Anaesth, 46, pp.R80~R87 (1999)
  14. Gonsowski CT, "Subanesthetic concentrations of desflurane and isoflurane suppress explicit and implicit learning", Anesth Analg, 80, pp.568~572 (1995)

관련 논문AI추천

Bispectral Index Monitoring during Anesthesiologist-Directed Propofol and Remifentanil Sedation for Endoscopic Submucosal Dissection: A Prospective Randomized Controlled Trial김소연, 박우영, 신양식, 이상길, 이태경, 최용선연세대학교의과대학 · Yonsei Medical Journal2014 · 제55권 제5호Use of the Bispectral Index to Predict Eye Position of Children during General Anesthesia국경훈, 김대희, 박수연, 정승아대한안과학회 · Korean Journal of Ophthalmology2018 · 제32권 제3호이중분광계수 모니터기반 진정제 투여가 내시경 점막하 박리술 환자의 의식하 진정상태, 생리적 안정성 및 회복시간에 미치는 효과강기주, 김재준, 박미옥, 이미정, 임현숙, 조명숙, 허지원, 황문숙병원간호사회 · 임상간호연구2012 · 제18권 제2호Effects of bispectral index monitoring as an adjunct to nurse-administered propofol combined sedation during colonoscopy: a randomized clinical trial허준, 정민규, Chang Min Cho, Hyun Seok Lee, Seong Woo Jeon, Sung Kook Kim, Young Hoon Jeon대한내과학회 · The Korean Journal of Internal Medicine2016 · 제31권 제2호뇌파 스펙트럼 분석에 의한 마취 심도 지표 개발김재형, 박준모, 백승완, 예수영, 전계록대한의용생체공학회 · 의공학회지2009 · 제30권 제4호Bispectral index-guided propofol sedation during endoscopic ultrasonographyAtsushi Nakai, Ayana Okamoto, Ken Kamata, Kentaro Yamao, Kosuke Minaga, Mamoru Takenaka, Masatoshi Kudo, Masayuki Kitano, Naoshi Nishida, Rei Ishikawa, Shunsuke Omoto, Takeshi Miyata, Tomoe Yoshikawa, Tomohiro Yamazaki, Toshiharu Sakurai, Yasutaka Chiba대한소화기내시경학회 · Clinical Endoscopy2022 · 제55권 제4호