본문 바로가기
KERD
논문KCI 등재

Experiences of healthcare providers and patients with diabetes mellitus regarding continuous glucose monitoring use in South Korea: a multicenter, cross-sectional survey study

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류의학일반

초록

Background Despite the increasing use of continuous glucose monitoring (CGM) systems, limited data exist on their perceived benefits and challenges among patients and healthcare providers. This study explored CGM-related experiences in South Korea. Methods An anonymous online survey was conducted between January and December 2021 at four university hospitals. Respondents included patients with diabetes mellitus (DM), physicians, and DM education nurses. The survey assessed the use of CGM, its benefits, and barriers. Most devices were first-generation CGMs: FreeStyle Libre 1 (Abbott Diabetes Care), Dexcom G6 (Dexcom Inc.), and Medtronic Guardian 3 (Medtronic MiniMed). Results Among 1,010 patients (33.4% with type 1 DM [T1DM], 63.6% with type 2 DM [T2DM], and 3.1% others; mean age, 51.4±14.6 years), 92.7% found CGM helpful. Although 59.6% reported discomfort, 81.9% intended to continue using CGM, indicating that perceived benefits outweighed barriers. The key advantages were glucose monitoring without finger pricks (T1DM, 57.9%; T2DM, 56.2%) and maintenance of target glucose levels. Discomfort was related to discomfort during activities (53.8%), skin problems (45.0%), and pain (43.0%). Healthcare provider recommendations were associated with reduced discomfort (adjusted odds ratio, 0.36; 95% confidence interval, 0.21–0.60). Physicians (n=29) cited high costs as the main barrier (T1DM, 58.9%; T2DM, 64.8%); only 51.9% and 14.5% prescribed CGM for T1DM and T2DM, respectively. Insulin adjustment and glucose control were the main reasons for prescription, while cost (89.3%) and limited consultation time (67.9%) were barriers. DM educators (n=9) reported heavy workloads, with training and follow-up times averaging 31.7±7.5 minutes and 21.7±9.7 minutes, respectively; 77.8% of DM educators identified frequent patient inquiries as their greatest burden. Conclusion CGM provides significant clinical benefits but is limited by discomfort, costs, and educational burden. Sustained adoption requires device improvements, insurance support, and workforce expansion.

Abstract

Background Despite the increasing use of continuous glucose monitoring (CGM) systems, limited data exist on their perceived benefits and challenges among patients and healthcare providers. This study explored CGM-related experiences in South Korea. Methods An anonymous online survey was conducted between January and December 2021 at four university hospitals. Respondents included patients with diabetes mellitus (DM), physicians, and DM education nurses. The survey assessed the use of CGM, its benefits, and barriers. Most devices were first-generation CGMs: FreeStyle Libre 1 (Abbott Diabetes Care), Dexcom G6 (Dexcom Inc.), and Medtronic Guardian 3 (Medtronic MiniMed). Results Among 1,010 patients (33.4% with type 1 DM [T1DM], 63.6% with type 2 DM [T2DM], and 3.1% others; mean age, 51.4±14.6 years), 92.7% found CGM helpful. Although 59.6% reported discomfort, 81.9% intended to continue using CGM, indicating that perceived benefits outweighed barriers. The key advantages were glucose monitoring without finger pricks (T1DM, 57.9%; T2DM, 56.2%) and maintenance of target glucose levels. Discomfort was related to discomfort during activities (53.8%), skin problems (45.0%), and pain (43.0%). Healthcare provider recommendations were associated with reduced discomfort (adjusted odds ratio, 0.36; 95% confidence interval, 0.21–0.60). Physicians (n=29) cited high costs as the main barrier (T1DM, 58.9%; T2DM, 64.8%); only 51.9% and 14.5% prescribed CGM for T1DM and T2DM, respectively. Insulin adjustment and glucose control were the main reasons for prescription, while cost (89.3%) and limited consultation time (67.9%) were barriers. DM educators (n=9) reported heavy workloads, with training and follow-up times averaging 31.7±7.5 minutes and 21.7±9.7 minutes, respectively; 77.8% of DM educators identified frequent patient inquiries as their greatest burden. Conclusion CGM provides significant clinical benefits but is limited by discomfort, costs, and educational burden. Sustained adoption requires device improvements, insurance support, and workforce expansion.

관련 논문AI추천

제1형 당뇨병에서 연속혈당측정기 사용의 비용효과성의 체계적 문헌고찰김희선, 박종연, 장나라한국보건의료기술평가학회 · 보건의료기술평가2020 · 제8권 제1호A Pilot Study Examining If the Additional Use of a Continuous Glucose Monitoring Is Helpful for Glucose Control in Older Adults김광준, 김창오, 김헌성, 박양선, 선은서, 신지원, 임현우, 조은아연세대학교의과대학 · Yonsei Medical Journal2025 · 제66권 제6호Current status of continuous glucose monitoring among Korean children and adolescents with type 1 diabetes mellitusKim Jae Hyun대한소아내분비학회 · Annals of Pediatric Endocrinology & Metabolism2020 · 제25권 제3호고혈당으로 입원한 2형당뇨병 환자에서 퇴원 시 연속혈당측정기를 이용한 당뇨병교육이 혈당 및 자가관리에 미치는 효과분석: 예비연구나영, 송복례, 심강희, 이정화, 정인경, 최영진대한산업경영학회 · 산업융합연구2025 · 제23권 제3호The role of continuous glucose monitoring in improving glycemic control in adolescents with type 1 diabetesKang Eungu, Kim EunJeong, Lee Kee-Hyoung, Nam Hyo-Kyoung, Park Ji Won, Park Kyu Hyun, Rhie Young-Jun, Seo Minkyu, Shin Do young대한소아내분비학회 · Annals of Pediatric Endocrinology & Metabolism2025 · 제30권 제5호The durability and effectiveness of sensor-augmented insulin pump therapy in pediatric and young adult patients with type 1 diabetes이윤정, Chung Hye Rim, Gu Min Jeong, Kim Jae Hyun, Kim Ji Young, Lee Young Ah, Shin Choong Ho대한소아내분비학회 · Annals of Pediatric Endocrinology & Metabolism2020 · 제25권 제4호

이 간행물의 다른 논문 (79건)