초록

Background and Objectives: Recurrent laryngeal nerve (RLN) damage commonly occurs from a thyroid surgery and causes communication impairment, aspiration and dysphagia. The purpose of this study is to develop a polycaprolactone (PCL) nerve guide conduit (NGC) coated with conductive materials for facilitating regeneration from the RLN defects and to evaluate the usefulness of the PCL NGC coated with conductive materials in a rabbit model. Materials and Methods: The PCL NGCs coated with conductive materials were fabricated for this study. The types of conductive materials were single-walled carbon nanotubes (SWNTs) and poly (3,4-ethylenedioxythiophene): polystyrene sulfonate (PEDOT:PSS) which were coated on the PCL NGCs by layer-by-layer (LBL) assembly techniques. An 8-mm segment of left RLN was resected in 24 New Zealand white rabbits. Three different NGCs (PCL and PCL with two conductive materials) were interposed between both stumps and fixed with suture. For the assessment of functional regeneration, the vocal cord mobility was observed using endoscopic system after RLN stimulation, and the motion change was analyzed. The atrophies of thyroarytenoid muscle and nerve growth were evaluated by Hematoxylin-Eosin (H-E) and toluidine blue (T-B) staining, respectively. Immunohistochemical study using anti-neurofilament, S-100 staining was further performed to evaluate the nerve regeneration. Results: In endoscopic evaluation, the group with conductive PCL NGCs showed an improved tendency of vocal cord mobility compared to that of the other group. Nerve growth was observed with the time for 8 weeks in all groups and immunohistochemical staining revealed the expression of neurofilament and S-100 in regenerated nerve in all groups. The atrophies of thyroarytenoid muscle in the group with conductive PCL NGCs was also shown to be decreased compared to that of the nonconductive PCL NGC group. Conclusion: The study shows that PCL NGC coated with conductive materials appears to be a good alternative option for the repair and regeneration of RNL damages.

Abstract

Background and Objectives: Recurrent laryngeal nerve (RLN) damage commonly occurs from a thyroid surgery and causes communication impairment, aspiration and dysphagia. The purpose of this study is to develop a polycaprolactone (PCL) nerve guide conduit (NGC) coated with conductive materials for facilitating regeneration from the RLN defects and to evaluate the usefulness of the PCL NGC coated with conductive materials in a rabbit model. Materials and Methods: The PCL NGCs coated with conductive materials were fabricated for this study. The types of conductive materials were single-walled carbon nanotubes (SWNTs) and poly (3,4-ethylenedioxythiophene): polystyrene sulfonate (PEDOT:PSS) which were coated on the PCL NGCs by layer-by-layer (LBL) assembly techniques. An 8-mm segment of left RLN was resected in 24 New Zealand white rabbits. Three different NGCs (PCL and PCL with two conductive materials) were interposed between both stumps and fixed with suture. For the assessment of functional regeneration, the vocal cord mobility was observed using endoscopic system after RLN stimulation, and the motion change was analyzed. The atrophies of thyroarytenoid muscle and nerve growth were evaluated by Hematoxylin-Eosin (H-E) and toluidine blue (T-B) staining, respectively. Immunohistochemical study using anti-neurofilament, S-100 staining was further performed to evaluate the nerve regeneration. Results: In endoscopic evaluation, the group with conductive PCL NGCs showed an improved tendency of vocal cord mobility compared to that of the other group. Nerve growth was observed with the time for 8 weeks in all groups and immunohistochemical staining revealed the expression of neurofilament and S-100 in regenerated nerve in all groups. The atrophies of thyroarytenoid muscle in the group with conductive PCL NGCs was also shown to be decreased compared to that of the nonconductive PCL NGC group. Conclusion: The study shows that PCL NGC coated with conductive materials appears to be a good alternative option for the repair and regeneration of RNL damages.

참고문헌 (27)

  1. Randolph GW, "The importance of pre- and postoperative laryngeal examination for thyroid surgery", Thyroid, 20(5), pp.453~458 (2010)
  2. Gardner GM, "The cost of vocal fold paralysis after thyroidectomy", Laryngoscope, 123(6), pp.1455~1463 (2013)
  3. Millesi H, "Reappraisal of nerve repair", Surg Clin North Am, 61(2), pp.321~340 (1981)
  4. Wang S, "Acceleration effect of basic fibroblast growth factor on the regeneration of peripheral nerve through a 15-mm gap", J Biomed Mater Res A, 66(3), pp.522~531 (2003)
  5. Widmer MS, "Manufacture of porous biodegradable polymer conduits by an extrusion process for guided tissue regeneration", Biomaterials, 19(21), pp.1945~1955 (1998)
  6. Kiyotani T, "Nerve regeneration across a 25-mm gap bridged by a polyglycolic acid-collagen tube: a histological and electrophysiological evaluation of regenerated nerves", Brain Res, 740(1-2), pp.66~74 (1996)
  7. Pettersson J, "Muscle recovery after repair of short and long peripheral nerve gaps using fibrin conduits", Neurosci Lett, 500(1), pp.41~46 (2011)
  8. Keilhoff G, "Bio-compatibility of type I", III collagen matrix for peripheral nerve reconstruction, 2003, pp.24(16), 2779~2787
  9. Choi JS, "Functional regeneration of recurrent laryngeal nerve injury during thyroid surgery using an asymmetrically porous nerve guide conduit in an animal model", Thyroid, 24(1), pp.52~59 (2014)
  10. Oh SH, "Effect of surface pore structure of nerve guide conduit on peripheral nerve regeneration", Tissue Eng Part C Methods, 19(3), pp.233~243 (2013)
  11. Kim H, "Stretchable conducting materials with multi-scale hierarchical structures for biomedical applications", Proceedings of SPIE 9172, Nanostructured Thin Films VII, 91720D, 9172, pp.91720D~ (2014)
  12. Lee WT, "Results of ansa to recurrent laryngeal nerve reinnervation", Otolaryngol Head Neck Surg, 136(3), pp.450~454 (2007)
  13. Mu LC, "Electromyographic study on end-to-end anastomosis of the recurrent laryngeal nerve in dogs", Laryngoscope, 100(9), pp.1009~1017 (1990)
  14. Nahm I, "Misdirected regeneration of injured recurrent laryngeal nerve in the cat", Am J Otolaryngol, 14(1), pp.43~48 (1993)
  15. Crumley RL, "Laryngeal synkinesis: its significance to the laryngologist", Ann Otol Rhinol Laryngol, 98(2), pp.87~92 (1989)
  16. Nahm I, "Regeneration of the recurrent laryngeal nerve in the guinea pig: reorganization of motoneurons after freezing injury", Am J Otolaryngol, 11(2), pp.90~98 (1990)
  17. de Ruiter GC, "Designing ideal conduits for peripheral nerve repair", Neurosurg Focus, 26(2), pp.E5~ (2009)
  18. Azzam NA, "Nerve cables formed in silicone chambers reconstitute a perineurial but not a vascular endoneurial permeability barrier", J Comp Neurol, 314(4), pp.807~819 (1991)
  19. 이상규, "Graphene: an emerging material for biological tissue engineering", Carbon Letters, 14(2), pp.63~75 (2013), 한국탄소학회
  20. Malarkey EB, "Conductive single-walled carbon nanotube substrates modulate neuronal growth", Nano Lett, 9(1), pp.264~268 (2009)
  21. Park SY, "Enhanced differentiation of human neural stem cells into neurons on graphene", Adv Mater, 23(36), pp.H263~267 (2011)
  22. del Valle LJ, "Cellular adhesion and proliferation on poly(3,4-ethylenedioxythiophene): Benefits in the electroactivity of the conducting polymer", Eur Polym J, 43(6), pp.2342~2349 (2007)
  23. Schmidt CE, "Stimulation of neurite outgrowth using an electrically conducting polymer", Proc Natl Acad Sci U S A, 94(17), pp.8948~8953 (1997)
  24. Hwang JY, "Biofunctionalized carbon nanotubes in neural regeneration: a mini-review", Nanoscale, 5(2), pp.487~497 (2013)
  25. Jakubiec B, "In vitro cellular response to polypyrrole-coated woven polyester fabrics: potential benefits of electrical conductivity", J Biomed Mater Res, 41(4), pp.519~526 (1998)
  26. Iizuka T, "Experimental studies on the nerve interception and atrophy of the intrinsic muscles of the larynx", Nihon Jibiinkoka Gakkai Kaiho, 69(2), pp.176~195 (1966)
  27. Pan YA, "Effects of neurotoxic and neuroprotective agents on peripheral nerve regeneration assayed by time-lapse imaging in vivo", J Neurosci, 23(36), pp.11479~11488 (2003)

관련 논문AI추천

이 간행물의 다른 논문 (17건)