최소 침습적 개방 갑상선 엽절제술에서 피부 전극을 이용한 반회후두신경의 수술 중 신경감시술
Intraoperative Neuromonitoring of Recurrent Laryngeal Nerve Using Adhesive Skin Electrodes during Minimally Invasive Open Hemithyroidectomy
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background: Intraoperative neuromonitoring (IONM) using adhesive skin electrodes has been reported to be useful method for preserving recurrent laryngeal nerve (RLN) in thyroid surgery. The aim of this study is to investigate the usefulness of IONM using adhesive skin electrodes in minimally invasive open hemithyroidectomy. Materials and Methods: A retrospective study was conducted on 23 patients diagnosed with micropapillary thyroid carcinoma from May 2020 to August 2022 who underwent minimally invasive open hemithyroidectomy. Adhesive skin electrodes were attached to the skin in the area of the lateral border of the thyroid cartilage lamina. Hemithyroidectomy was performed by approaching between sternocleidomastoid and strap muscles, after a 3-4 cm horizontal skin incision. We collected the data regarding age, sex, mean amplitude and latency of evoked electromyogram (EMG) (V1, R1, R2, V2). Results: The amplitude of EMG from vagus and RLN was successfully measured. The mean amplitude was measured as 239.2 μV for V1, 278.0 μV for R1, 362.1 μV for R2, and 307.0 μV for V2, respectively. Conclusion: The monitoring using adhesive skin electrodes is good alternative method of IONM using EMG endotracheal tube for preserving RLN during minimally invasive open hemithyroidectomy.
Abstract
Background: Intraoperative neuromonitoring (IONM) using adhesive skin electrodes has been reported to be useful method for preserving recurrent laryngeal nerve (RLN) in thyroid surgery. The aim of this study is to investigate the usefulness of IONM using adhesive skin electrodes in minimally invasive open hemithyroidectomy. Materials and Methods: A retrospective study was conducted on 23 patients diagnosed with micropapillary thyroid carcinoma from May 2020 to August 2022 who underwent minimally invasive open hemithyroidectomy. Adhesive skin electrodes were attached to the skin in the area of the lateral border of the thyroid cartilage lamina. Hemithyroidectomy was performed by approaching between sternocleidomastoid and strap muscles, after a 3-4 cm horizontal skin incision. We collected the data regarding age, sex, mean amplitude and latency of evoked electromyogram (EMG) (V1, R1, R2, V2). Results: The amplitude of EMG from vagus and RLN was successfully measured. The mean amplitude was measured as 239.2 μV for V1, 278.0 μV for R1, 362.1 μV for R2, and 307.0 μV for V2, respectively. Conclusion: The monitoring using adhesive skin electrodes is good alternative method of IONM using EMG endotracheal tube for preserving RLN during minimally invasive open hemithyroidectomy.
참고문헌 (19)
- Hermann M, "Laryngeal recurrent nerve injury in surgery for benign thyroid diseases : effect of nerve dissection and impact of individual surgeon in more than 27, 000 nerves at risk", Ann Surg, 235(2), pp.261~268 (2002)
- Hayward NJ, "Recurrent laryngeal nerve injury in thyroid surgery : a review", ANZ J Surg, 83(1-2), pp.15~21 (2013)
- Jeannon JP, "Diagnosis of recurrent laryngeal nerve palsy after thyroidectomy : a systematic review", Int J Clin Pract, 63(4), pp.624~629 (2009)
- Wong KP, "Systematic review and meta-analysis on intra-operative neuro-monitoring in high-risk thyroidectomy", Int J Surg, 38, pp.21~30 (2017)
- Bai B, "Protective effects of intraoperative nerve monitoring(IONM)for recurrent laryngeal nerve injury in thyroidectomy : meta-analysis", Sci Rep, 8(1), pp.7761~ (2018)
- 신성찬, "갑상선 수술 중 바늘과 피부 전극을 이용한 새로운 신경감시술", International Journal of Thyroidology, 15(1), pp.17~22 (2022), 대한갑상선학회[DOI]
- Dralle H, "Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery", World J Surg, 32(7), pp.1358~1366 (2008)
- 이형신, "피부 전극을 활용한 반회후두신경의 수술 중 신경모니터링", 대한이비인후-두경부외과학회지, 64(1), pp.1~6 (2021), 대한이비인후과학회[DOI]
- Wu CW, "Transcutaneous recording during intraoperative neuromonitoring in thyroid surgery", Thyroid, 28(11), pp.1500~1507 (2018)
- Lee HS, "Intraoperative neuromonitoring of recurrent laryngeal nerve during thyroidectomy with adhesive skin electrodes", World J Surg, 44(1), pp.148~154 (2020)
- 태경, "로봇 갑상선 수술", 대한이비인후-두경부외과학회지, 53(8), pp.463~469 (2010), 대한이비인후과학회
- Liu SY, "Robotic versus open thyroidectomy for differentiated thyroid cancer : an evidence-based review", Int J Endocrinol, 2016, pp.4309087~ (2016)
- Singaporewalla RM, "The lateral "backdoor"approach to open thyroid surgery: a comparative study", Asian J Surg, 41(4), pp.384~388 (2018)
- Chandrasekhar SS, "Clinical practice guideline : improving voice outcomes after thyroid surgery", Otolaryngol Head Neck Surg, 148(6 Suppl), pp.S1~S37 (2013)
- Randolph GW, "Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery : international standards guideline statement", Laryngoscope, 121(Suppl 1), pp.S1~S16 (2011)
- Chiang FY, "Comparison of EMG signals recorded by surface electrodes on endotracheal tube and thyroid cartilage during monitored thyroidectomy", Kaohsiung J Med Sci, 33(10), pp.503~509 (2017)
- Wu CW, "Feasibility of intraoperative neuromonitoring during thyroid surgery using transcartilage surface recording electrodes", Thyroid, 28(11), pp.1508~1516 (2018)
- Li P, "The transcutaneous electromyography recording method for intraoperative neuromonitoring of recurrent laryngeal nerve during minimally invasive parathyroidectomy", Sci Rep, 10(1), pp.7609~ (2020)
- Shin SC, "Investigation of attachment location of adhesive skin electrodes for intraoperative neuromonitoring in thyroid surgery : preclinical and clinical studies", Surgery, 171(2), pp.377~383 (2022)
