Purpose: Energy devices, such as Harmonic Focus Plus (Ethicon; ultrasonic scalpel; Harmonic) and Ligasure Small Jaw (Covidien; bipolar sealer; Ligasure) are widely used in thyroid surgery as substitutes for Bovie (electrocautery) and sutures. They reduce operation time and peri-operative complications. Thunderbeat Open Fine Jaw (Olympus; Thunderbeat) is a recently developed energy device, which combines the functions of both ultrasonic scalpel and bipolar sealer. We prospectively evaluated the safety and feasibility of Thunderbeat during open thyroidectomy compared with Harmonic and Ligasure. Methods: From September to November 2016, patients with papillary thyroid cancer or benign thyroid disease who underwent unilateral or bilateral thyroidectomy at Samsung Medical Center were enrolled. Thyroidectomies were performed by a single surgeon who specializes in endocrine surgery and is experienced in using energy devices. The patients were randomly allocated to one of the 3 groups according to the energy device used during the operation: Harmonic, Ligasure, and Thunderbeat group. Results: No significant differences were detected among the 3 groups in intra-operative bleeding, drainage amount, incidence of transient hypocalcemia, and transient vocal cord palsy. The surgical time for thyroidectomy in the T group was shorter than in the other 2 groups (P=0.031). However, the H group showed reduced surgical time for central lymph node dissection. Conclusion: Among the 3 energy devices, Thunderbeat and Harmonic shortened the surgical time for thyroidectomy and central lymph node dissection, respectively. However, each energy device has its own strengths and weaknesses, and we recommend the selection of devices based on the respective features.

Abstract

Purpose: Energy devices, such as Harmonic Focus Plus (Ethicon; ultrasonic scalpel; Harmonic) and Ligasure Small Jaw (Covidien; bipolar sealer; Ligasure) are widely used in thyroid surgery as substitutes for Bovie (electrocautery) and sutures. They reduce operation time and peri-operative complications. Thunderbeat Open Fine Jaw (Olympus; Thunderbeat) is a recently developed energy device, which combines the functions of both ultrasonic scalpel and bipolar sealer. We prospectively evaluated the safety and feasibility of Thunderbeat during open thyroidectomy compared with Harmonic and Ligasure. Methods: From September to November 2016, patients with papillary thyroid cancer or benign thyroid disease who underwent unilateral or bilateral thyroidectomy at Samsung Medical Center were enrolled. Thyroidectomies were performed by a single surgeon who specializes in endocrine surgery and is experienced in using energy devices. The patients were randomly allocated to one of the 3 groups according to the energy device used during the operation: Harmonic, Ligasure, and Thunderbeat group. Results: No significant differences were detected among the 3 groups in intra-operative bleeding, drainage amount, incidence of transient hypocalcemia, and transient vocal cord palsy. The surgical time for thyroidectomy in the T group was shorter than in the other 2 groups (P=0.031). However, the H group showed reduced surgical time for central lymph node dissection. Conclusion: Among the 3 energy devices, Thunderbeat and Harmonic shortened the surgical time for thyroidectomy and central lymph node dissection, respectively. However, each energy device has its own strengths and weaknesses, and we recommend the selection of devices based on the respective features.

참고문헌 (16)

  1. Fagotti A, "Randomized study comparing use of THUNDERBEAT technology vs standard electrosurgery during laparoscopic radical hysterectomy and pelvic lymphadenectomy for gynecologic cancer", J Minim Invasive Gynecol, 21, pp.447~453 (2014)
  2. Obonna GC, "Differences between Thunderbeat, Ligasure and Harmonic scalpel energy system in minimally invasive surgery", World J Laparos Surg, 7, pp.41~44 (2014)
  3. Seehofer D, "Safety and efficacy of new integrated bipolar and ultrasonic scissors compared to conventional laparoscopic 5-mm sealing and cutting instruments", Surg Endosc, 26, pp.2541~2549 (2012)
  4. Edge SB, "AJCC Cancer Staging Manual" (2010), Springer
  5. Lang BH, "Does using an energized device in open thyroidectomy reduce complications?", J Surg Res, 181, pp.e23~e29 (2013)
  6. Garas G, "Which hemostatic device in thyroid surgery? A network meta-analysis of surgical technologies", Thyroid, 23, pp.1138~1150 (2013)
  7. Ruggiero R, "Sutureless thyroidectomy", Int J Surg, 12(Suppl 1), pp.S189~S193 (2014)
  8. Alexiou K, "The use of new energy-based haemostatic methods in thyroid surgery : sutureless total thyroidectomy(ultrasonic coagulation and", or electro thermal bipolar vessel sealing system)versus classic suture ligation(clamp-and-tie)technique, 2015, pp.87, 92~96
  9. Teksoz S, "Sutureless thyroidectomy with energy-based devices : cerrahpasa experience", Updates Surg, 65, pp.301~307 (2013)
  10. Kwak HY, "Comparison of surgical outcomes between papillary thyroid cancer patients treated with the Harmonic ACE scalpel and LigaSure Precise instrument during conventional thyroidectomy : a single-blind prospective randomized controlled trial", J Surg Res, 187, pp.484~489 (2014)
  11. Dionigi G, "The safety of energy-based devices in open thyroidectomy : a prospective, randomised study comparing the LigaSure™(LF1212)and the Harmonic® FOCUS", Langenbecks Arch Surg, 397, pp.817~823 (2012)
  12. Van Slycke S, "Comparison of the Harmonic focus and the Thunderbeat for open thyroidectomy", Langenbecks Arch Surg, 401, pp.851~859 (2016)
  13. Smith CT, "Infrared thermographic profiles of vessel sealing devices on thyroid parenchyma", J Surg Res, 170, pp.64~68 (2011)
  14. Applewhite MK, "Ultrasonic, bipolar, and integrated energy devices : comparing heat spread in collateral tissues", J Surg Res, 207, pp.249~254 (2017)
  15. Kwak HY, "Thermal injury of the recurrent laryngeal nerve by THUNDERBEAT during thyroid surgery : findings from continuous intraoperative neuromonitoring in a porcine model", J Surg Res, 200, pp.177~182 (2016)
  16. Park MW, "Long-term voice outcome after thyroidectomy using energy based devices", Auris Nasus Larynx, 45, pp.527~532 (2018)

관련 논문AI추천

Usefulness of the Harmonic Scalpel in Thyroid Surgery최환, 권순영, 박민우, 백승국, 우정수, 정광윤대한갑상선학회 · International Journal of Thyroidology2012 · 제5권 제2호갑상선 전 절제술과 경부 중앙 림프절 절제술 시 하모닉 포커스(Harmonic Focus) 사용의 안전성과 효용성에 대한 무작위 배정 연구김지선, 김홍규, 김훈엽대한내분비외과학회 · Journal of Endocrine Surgery2017 · 제17권 제1호Letter to the Editor: A Prospective, Randomized, Controlled Comparative Study of Three Energy Devices in Open Thyroid Surgery: Thunderbeat, Harmonic, and LigasureMayilvaganan Sabaretnam, Vnssvams Mahalakshmi D대한내분비외과학회 · Journal of Endocrine Surgery2020 · 제20권 제1호Post-operative Hypocalcaemia Following Open Thyroidectomy for Benign Multinodular Goiters Using FOCUS Harmonic Scalpel Versus Conventional Suture Ligation Technique for Hemostasis: a Prospective, Single-blind, Randomized Controlled TrialSadaf Zehra, Sughra Parveen대한내분비외과학회 · Journal of Endocrine Surgery2018 · 제18권 제2호Author's Response: A Prospective, Randomized, Controlled Comparative Study of Three Energy Devices in Open Thyroid Surgery: Thunderbeat, Harmonic, and LigasureJee Soo Kim대한내분비외과학회 · Journal of Endocrine Surgery2020 · 제20권 제1호Harmonic versus LigaSure for Flap Creation in Bilateral Axillary Breast Approach Thyroid Surgery이진욱, Ahn Jong-hyuk, Choi Seong Woon, Choi Yun Suk, Kim Jae Hwan, Ryu Han Byul대한내분비외과학회 · Journal of Endocrine Surgery2020 · 제20권 제4호

이 간행물의 다른 논문 (9건)