고어텍스 이식물의 수술 전 처치 방법과 이에 대한 유용성 연구
Usefulness of Preoperative Preparation in Using Gore-Tex
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background and Objectives:Gore-Tex is a popular graft material used in rhinoplasty. But there are several complications such as infection, seroma, and persistent swelling. Infection is the most common complication. The aim of this study was the evaluation of various protocols for Gore-Tex decontamination. Subjects and Method:Gore-Tex specimens were sectioned and separated into six groups. These were treated with povidone-iodine or antibiotics solution. Nasal cavity swab was performed both in the control group and patient group of chronic sinusitis. The culture of swab specimens incubated in agar plates were compared statistically. Results:Povidone-iodine groups revealed significant decrease in the bacterial colony counts. Conclusion:The results suggested that impregnation of povidone-iodine supports the efficacy of decontamination Gore-Tex Implant.
Abstract
Background and Objectives:Gore-Tex is a popular graft material used in rhinoplasty. But there are several complications such as infection, seroma, and persistent swelling. Infection is the most common complication. The aim of this study was the evaluation of various protocols for Gore-Tex decontamination. Subjects and Method:Gore-Tex specimens were sectioned and separated into six groups. These were treated with povidone-iodine or antibiotics solution. Nasal cavity swab was performed both in the control group and patient group of chronic sinusitis. The culture of swab specimens incubated in agar plates were compared statistically. Results:Povidone-iodine groups revealed significant decrease in the bacterial colony counts. Conclusion:The results suggested that impregnation of povidone-iodine supports the efficacy of decontamination Gore-Tex Implant.
참고문헌 (11)
- Neel HB 3rd, "Implants of Gore-Tex", Arch Otolaryngol, 109(7), pp.427~433 (1983)
- Jin HR, "multicenter evaluation of the safety of Gore-Tex as an implant in Asian rhinoplasty", Am J Rhinol, 20(6), pp.615~619 (2006)
- Mendelsohn M, "Gore-Tex augmentaion grafting in rhinoplasty--is it safe?", J Otolaryngol, 27(6), pp.337~341 (1998)
- Inanli S, "The use of expanded polytetrafluoroethylene (Gore-Tex) in rhinoplasty", Aesthetic Plast Surg, 31(4), pp.345~348 (2007)
- Rothstein SG, "The use of Gore-Tex implants in nasal augmentation operations", Ear Nose Throat J, (68), pp.40~45 (1989)
- Owsley TG, "The use of Gore-Tex for nasal augmentation: A retrospective analysis of 106 patients", Plast Reconstr Surg, 94(2), pp.241~248 (1994)
- 박찬흠, "인체의 융비술에 사용된 Gore-Tex ? 조직학적 변화", 대한이비인후과학회지 두경부외과학, 48(2), pp.182~188 (2005), 대한이비인후과학회
- 박찬흠, "토끼 비배부에 삽입된 강화 고어텍스의 조직학적, 형태학적 변화", 대한이비인후과학회지 두경부외과학, 51(8), pp.705~711 (2008), 대한이비인후과학회
- Conrad K, "Applications of Gore-Tex implants in rhinoplasty reexamined after 17 years", Arch Facial Plast Surg, 10(4), pp.224~231 (2008)
- Kozuka T, "Patch testing to exclude allergic contact dermatitis caused by povidone-iodine", Dermatology, (204), pp.96~98 (2002)
- Robert FC, "Management of contaminated autologous grafts in plastic surgery", J Plastic Surgery, (8), pp.211~224 (2008)
