초록
Background and ObjectivesZZTo standard test method of Korean speech audiometry, we developed an audio compact disk, the KsoM-07 (Korean Society of Otolaryngolgy, Monosyllabic,2007) word lists and evaluated them for clinical usage. Subjects and MethodZZThe monitored live voice (MLV) of a female talker was digitally recorded with a Beltone audiometer and the GoldWave program. The calibration for each word was done by calculating the root-mean-square (RMS) at the moving time of 300 ms using MATLAB ® (7.0 version, The MathWorks, Inc. Natick, Massachusetts, USA) and the GoldWave (v 5.25 GoldWave Inc. St. John’s, NL, Canada) program. The discrimination score was measured in 20 normal subjects to obtain psychometric function curve of each word and to compare the homogeneity of two lists. The first verification methods for new speech materials were done by comparing the discrimination scores of the flat type and the descending types at 150 sensorineural hearing loss with similar pure tone threshold. ResultsZZ44% of MLV recording was above ±3 dB deviation and had to be recalibrated. Two lists showed equal difficulty or homogeneity in normal subjects. Discrimination scores were statistically different among the groups with respect to hearing level and the slope of audiogram. ConclusionZZKsoM-07 word lists were relatively homogeneous and showed differences between the descending type and the flat type of hearing loss. Therefore, KsoM-07 word lists can be useful in evaluating the impairment found in the descending type of sensorineural hearing loss as well as in serving as a new speech test material for Korean monosyllabic words. Korean J Otorhinolaryngol-Head Neck Surg 2010;53:290-9
Abstract
Background and ObjectivesZZTo standard test method of Korean speech audiometry, we developed an audio compact disk, the KsoM-07 (Korean Society of Otolaryngolgy, Monosyllabic,2007) word lists and evaluated them for clinical usage. Subjects and MethodZZThe monitored live voice (MLV) of a female talker was digitally recorded with a Beltone audiometer and the GoldWave program. The calibration for each word was done by calculating the root-mean-square (RMS) at the moving time of 300 ms using MATLAB ® (7.0 version, The MathWorks, Inc. Natick, Massachusetts, USA) and the GoldWave (v 5.25 GoldWave Inc. St. John’s, NL, Canada) program. The discrimination score was measured in 20 normal subjects to obtain psychometric function curve of each word and to compare the homogeneity of two lists. The first verification methods for new speech materials were done by comparing the discrimination scores of the flat type and the descending types at 150 sensorineural hearing loss with similar pure tone threshold. ResultsZZ44% of MLV recording was above ±3 dB deviation and had to be recalibrated. Two lists showed equal difficulty or homogeneity in normal subjects. Discrimination scores were statistically different among the groups with respect to hearing level and the slope of audiogram. ConclusionZZKsoM-07 word lists were relatively homogeneous and showed differences between the descending type and the flat type of hearing loss. Therefore, KsoM-07 word lists can be useful in evaluating the impairment found in the descending type of sensorineural hearing loss as well as in serving as a new speech test material for Korean monosyllabic words. Korean J Otorhinolaryngol-Head Neck Surg 2010;53:290-9
참고문헌 (14)
- 변성완, "단음절어표의 제작에서 종성과 관련된 음소 빈도의 조정", 대한이비인후과학회지 두경부외과학, 50(7), pp.573~578 (2007), 대한이비인후과학회
- Noh H, "Acoustic analyses of monosyllabic words which are difficult to discriminate in the high frequency hearing loss", Korean J Otolaryngol-Head Neck Surg, 44(7), pp.700~706 (2001)
- 박무균, "어음청력검사 어음표의 주파수별 음향학적 특성에 관한 연구", 대한이비인후과학회지 두경부외과학, 50(6), pp.480~485 (2007), 대한이비인후과학회
- Tchae S, "Acoustically and phonemically balanced Korean monosyllabic word lists", The Newest Medical Journal, 48(2), pp.80~94 (2005)
- Noh H, "A suggestion of the simple verification method for new speech materials", Korean J Audiol, 10(2), pp.129~134 (2006)
- Harris RW, "Psychometrically equivalent Russian speech audiometry materials by male and female talkers", Int J Audiol, 46(1), pp.47~66 (2007)
- Wilson RH, "Clinical use of the compact disc in speech audiometry", ASHA, 32, pp.47~51 (1990)
- Wilson RH, "Development and use of auditory compact discs in auditory evaluation", J Rehabil Res Dev, 30(3), pp.342~351 (1993)
- Katz J, "Handbook of clinical audiology in Speech Audiometry", pp.96~110 (2002), Lippincott Williams & Wilkins
- Wilson RH, "Normative data in quiet, broadband noise, and competing message for Northwestern University Auditory Test No. 6 by a female speaker", J Speech Hear Disord, 55(4), pp.771~778 (1990)
- Markides A, "Speech levels and speech-to-noise ratios", Br J Audiol, 20(2), pp.115~120 (1986)
- Kim JS, "Development of Korean standard monosyllabic word lists for adults (KS-MWL-A)", Korean Academy of Audiology, 4, pp.126~140 (2008)
- Wilson RH, "Psychometric functions for the CID W-22 and NU Auditory Test No. 6. Materials spoken by the same speaker", Ear Hear, 18(5), pp.430~433 (1997)
- Wilson RH, "Relation between slopes of word recognition psychometric functions and homogeneity of the stimulus materials", J Am Acad Audiol, 12(1), pp.7~14 (2001)