생선 뼈 이물모델의 전산화단층촬영에서 도출한 삼차원 재구성 방법의 임상적 응용
Clinical Application of 3 Dimensional Reconstruction of CT from Fish Bone Foreign Body Model
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Background and Objectives This study aimed to gather three-dimensional data to detect fish bones as an esophageal foreign body model and to assess the possibility that this method could be applied for cases of real fish bone foreign body (FBFB). Materials and Method Fish bones from two species were collected and sizes were measured. Pork meat loaf was placed flat into a plastic box containing plaster cast and bones were laid over the meat layer. Another layer of meat was placed on the bones, then another layer of plaster cast, and the final layer of meat were placed. The meat-bone sandwich was regarded as a fish bone foreign body model of esophagus. The model was imaged using computed tomography (CT) scan and the CT data were reconstructed three-dimensionally making multi-planar reconstruction, maximal intensity projection, and volume rendering images. We tried to find tools to detect the shape and lying position of the FBFB model. The above tools were applied to 3 FBFB cases to verify effectiveness of the tools. Results Multi-planar reconstruction, maximal intensity projection, and volume rendering images were reconstructed easily. After single or more processing, all of the bones could be detected. The shape and lying positions could be detected using tools made from FBFB models. Conclusion Reconstructed images of CT data readily enabled the detection of fish bone in the esophageal model and real cases. Korean J Otorhinolaryngol-Head Neck Surg 2014;57(4):244-50
Abstract
Background and Objectives This study aimed to gather three-dimensional data to detect fish bones as an esophageal foreign body model and to assess the possibility that this method could be applied for cases of real fish bone foreign body (FBFB). Materials and Method Fish bones from two species were collected and sizes were measured. Pork meat loaf was placed flat into a plastic box containing plaster cast and bones were laid over the meat layer. Another layer of meat was placed on the bones, then another layer of plaster cast, and the final layer of meat were placed. The meat-bone sandwich was regarded as a fish bone foreign body model of esophagus. The model was imaged using computed tomography (CT) scan and the CT data were reconstructed three-dimensionally making multi-planar reconstruction, maximal intensity projection, and volume rendering images. We tried to find tools to detect the shape and lying position of the FBFB model. The above tools were applied to 3 FBFB cases to verify effectiveness of the tools. Results Multi-planar reconstruction, maximal intensity projection, and volume rendering images were reconstructed easily. After single or more processing, all of the bones could be detected. The shape and lying positions could be detected using tools made from FBFB models. Conclusion Reconstructed images of CT data readily enabled the detection of fish bone in the esophageal model and real cases. Korean J Otorhinolaryngol-Head Neck Surg 2014;57(4):244-50
참고문헌 (22)
- Irfan M, "Radio-opacity of commonly consumed bony fish in kelantan, malaysia", Med J Malaysia, 67(5), pp.491~493 (2012)
- Wang CP, "Migrating fish bone presenting as acute onset of neck lump", J Formos Med Assoc, 108(2), pp.170~172 (2009)
- Pinto A, "Role of imaging in the assessment of impacted foreign bodies in the hypopharynx and cervical esophagus", Semin Ultrasound CT MR, 33(5), pp.463~470 (2012)
- Siu WT, "Fish bone embedded in cervical esophagus", Auris Nasus Larynx, 32(3), pp.329~330 (2005)
- Palme CE, "Fish bones at the cricopharyngeus:a comparison of plain-film radiology and computed tomography", Laryngoscope, 109(12), pp.1955~1958 (1999)
- Eliashar R, "Computed tomography diagnosis of esophageal bone impaction: a prospective study", Ann Otol Rhinol Laryngol, 108(7 PT 1), pp.708~710 (1999)
- 김흥업, "Clinical Characteristics of an Esophageal Fish Bone Foreign Body from Chromis notata", Journal of Korean Medical Science, 27(10), pp.1208~1214 (2012), 대한의학회
- Lo WC, "Radiology quiz case 1. Migrating esophageal fish bone complicating a right paraesophageal abscess", Arch Otolaryngol Head Neck Surg, 134(9), pp.1008~1010 (2008)
- Das D, "Best evidence topic report. Is CT effective in cases of upper oesophageal fish bone ingestion?", Emerg Med J, 24(1), pp.48~49 (2007)
- Akazawa Y, "The management of possible fishbone ingestion", Auris Nasus Larynx, 31(4), pp.413~416 (2004)
- Kumar M, "Fish bone as a foreign body", J Laryngol Otol, 117(7), pp.568~569 (2003)
- Ariz C, "3D CT evaluation of retained foreign bodies", Emerg Radiol, 11(2), pp.95~99 (2004)
- Evans S, "3D imaging in forensic odontology", J Vis Commun Med, 33(2), pp.63~68 (2010)
- 허건, "기관지 및 식도 이물 모델에서의 가상 내시경", 대한이비인후과학회지 두경부외과학, 54(5), pp.339~343 (2011), 대한이비인후과학회
- Yoo YS, "Detection of simulative foreign body using three dimensional reconstruction technique, introduction and application", Korean J Bronchoesophagol, 17(1), pp.40~45 (2011)
- Watanabe K, "The prolonged presence of a fish bone in the neck", Tohoku J Exp Med, 227(1), pp.49~52 (2012)
- Park S, "Fish bone foreign bodies in the pharynx and upper esophagus: evaluation with 64-slice MDCT", Acta Radiol, 55(1), pp.8~13 (2014)
- Yang J, "Application of MPR in sacral nerve injury during sacral fracture", J Trauma, 70(6), pp.1489~1494 (2011)
- Isogai S, "Maximum intensity projection (MIP) and multiplanar reformation (MPR) for post-processing cholangiopancreatographic data set--clinical application and pitfalls", Nihon Rinsho, 56(11), pp.2760~2767 (1998)
- Sahel M, "3D-CT angiography with volume rendering technique in the intracerebral aneurysms", J Radiol, 81(2), pp.127~132 (2000)
- Prokesch RW, "Pseudoaneurysm of the internal carotid artery after shrapnel injury in World War II: demonstration by CT angiography with 3D MIP reconstruction", Eur Radiol, 9(7), pp.1441~1444 (1999)
- Rodt T, "Evaluation of surface and volume rendering in 3D-CT of facial fractures", Dentomaxillofac Radiol, 35(4), pp.227~231 (2006)
