새로운 유연성 단일 포트 로봇 수술 시스템을 이용한 후이개 접근 갑상선 절제술 소개 및 문헌고찰
Retroauricular Thyroidectomy Using a New Flexible, Single-Port Robotic Surgical System
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This study aimed to assess a new flexible, single-arm robotic surgical system to retroauricular thyroidectomy. Three fresh cadavers were used. Technical elements of the system and the whole surgical procedures were described in detail. This single-port flexible system could be used to successfully perform retroauricular thyroidectomy. The ideal angle to dock the patient-side cart was at a 90-degree angle to the operating table. When the cannula tip was placed 10-15 cm away from the skin incision, positioning and full movement of all four instruments without collisions were possible. Flexible three instruments and a stereoscope made the robotic dissection more efficient, safe and time-saving. We report the first preclinical evaluation of an innovative, flexible, single-arm robotic surgical system for retroauricular thyroidectomy. Korean J Otorhinolaryngol-Head Neck Surg 2017;60(12):593-8
Abstract
This study aimed to assess a new flexible, single-arm robotic surgical system to retroauricular thyroidectomy. Three fresh cadavers were used. Technical elements of the system and the whole surgical procedures were described in detail. This single-port flexible system could be used to successfully perform retroauricular thyroidectomy. The ideal angle to dock the patient-side cart was at a 90-degree angle to the operating table. When the cannula tip was placed 10-15 cm away from the skin incision, positioning and full movement of all four instruments without collisions were possible. Flexible three instruments and a stereoscope made the robotic dissection more efficient, safe and time-saving. We report the first preclinical evaluation of an innovative, flexible, single-arm robotic surgical system for retroauricular thyroidectomy. Korean J Otorhinolaryngol-Head Neck Surg 2017;60(12):593-8
참고문헌 (29)
- Adam MA, "Robotic thyroidectomy for cancer in the US: patterns of use and short-term outcomes", Ann Surg Oncol, 21(12), pp.3859~3864 (2014)
- Davies L, "Current thyroid cancer trends in the United States", JAMA Otolaryngol Head Neck Surg, 140(4), pp.317~322 (2014)
- Hegner CF, "A history of thyroid surgery", Ann Surg, 95(4), pp.481~492 (1932)
- Duh QY, "Robot-assisted endoscopic thyroidectomy: has the time come to abandon neck incisions?", Ann Surg, 253(6), pp.1067~1068 (2011)
- Sosa JA, "The importance of surgeon experience for clinical and economic outcomes from thyroidectomy", Ann Surg, 228(3), pp.320~330 (1998)
- Giddings AE, "The history of thyroidectomy", J R Soc Med, 91(Suppl 33), pp.3~6 (1998)
- Miccoli P, "Minimally invasive video-assisted thyroidectomy: five years of experience", J Am Coll Surg, 199(2), pp.243~248 (2004)
- Terris DJ, "Minimally invasive video-assisted thyroidectomy: a multi-institutional North American experience", Arch Otolaryngol Head Neck Surg, 134(1), pp.81~84 (2008)
- Lee KE, "Endoscopic thyroidectomy with the da Vinci robot system using the bilateral axillary breast approach (BABA) technique: our initial experience", Surg Laparosc Endosc Percutan Tech, 19(3), pp.e71~e75 (2009)
- Kang SW, "Robotic thyroid surgery using a gasless, transaxillary approach and the da Vinci S system: the operative outcomes of 338 consecutive patients", Surgery, 146(6), pp.1048~1055 (2009)
- Richmon JD, "Transoral robotic-assisted thyroidectomy with central neck dissection: preclinical cadaver feasibility study and proposed surgical technique", J Robot Surg, 5(4), pp.279~282 (2011)
- Holsinger FC, "Robotic thyroidectomy:operative technique using a transaxillary endoscopic approach without CO2 insufflation", Otolaryngol Clin North Am, 43(2), pp.381~388 (2010)
- Ban EJ, "Surgical complications after robotic thyroidectomy for thyroid carcinoma: a single center experience with 3,000 patients", Surg Endosc, 28(9), pp.2555~2563 (2014)
- Lee S, "The impact of body habitus on the surgical outcomes of transaxillary singleincision robotic thyroidectomy in papillary thyroid carcinoma patients", Surg Endosc, 27(7), pp.2407~2414 (2013)
- Lee J, "Robotic thyroidectomy and neck dissection: past, present, and future", Cancer J, 19(2), pp.151~161 (2013)
- Son H, "Factors contributing to surgical outcomes of transaxillary robotic thyroidectomy for papillary thyroid carcinoma", Surg Endosc, 28(11), pp.3134~3142 (2014)
- Kuppersmith RB, "Robotic thyroid surgery: an initial experience with North American patients", Laryngoscope, 121(3), pp.521~526 (2011)
- Perrier ND, "Why I have abandoned robot-assisted transaxillary thyroid surgery", Surgery, 152(6), pp.1025~1026 (2012)
- Hinson AM, "Trends in robotic thyroid surgery in the United States from 2009 through 2013", Thyroid, 25(8), pp.919~926 (2015)
- Gross ND, "Commentary: is robotic thyroid surgery worth the learning curve?", Otolaryngol Head Neck Surg, 147(6), pp.1047~1048 (2012)
- Broome JT, "Expense of robotic thyroidectomy: a cost analysis at a single institution", Arch Surg, 147(12), pp.1102~1106 (2012)
- Terris DJ, "Robotic facelift thyroidectomy:patient selection and technical considerations", Surg Laparosc Endosc Percutan Tech, 21(4), pp.237~242 (2011)
- Singer MC, "Robotic facelift thyroidectomy", Otolaryngol Clin North Am, 47(3), pp.425~431 (2014)
- Byeon HK, "Robotic total thyroidectomy with modified radical neck dissection via unilateral retroauricular approach", Ann Surg Oncol, 21(12), pp.3872~3875 (2014)
- Terris DJ, "Robotic facelift thyroidectomy: II. Clinical feasibility and safety", Laryngoscope, 121(8), pp.1636~1641 (2011)
- Lee J, "Robotic surgery for thyroid disease", Eur Thyroid J, 2(2), pp.93~101 (2013)
- "501(k) Summary:SP999 da Vinci® SpTM Surgical System 2014"[URL]
- Holsinger FC, "A flexible, single-arm robotic surgical system for transoral resection of the tonsil and lateral pharyngeal wall: nextgeneration robotic head and neck surgery", Laryngoscope, 126(4), pp.864~869 (2016)
- Kaouk JH, "A novel robotic system for single-port urologic surgery: first clinical investigation", Eur Urol, 66(6), pp.1033~1043 (2014)
