Response to the Comments on ‘Point of Care D-Dimer Testing in the Emergency Department–A Bioequivalence Study’ and Erratum to the Results

2

조회

0

다운로드

0

인용

0

참고문헌

주제분류병리학

초록

We have read with interest the comments made on our study ti- tled ‘Point of care (POC) D-dimer testing in the Emergency de- partment–a bioequivalence study’ [1]. Ekelund and Heilmann, referring to the results and conclu- sions of the study, have suggested that one of the discrepancies may be caused by a typographical error, and this inference prob- ably stems from the use of the term ‘range’ in the published arti- cle. This should have been termed ‘Bland-Altman limits of agree- ment’ (0.24-2.13) for all the cases where both tests were ordered and not just for the 8 POC-negative VIDAS (VIDAS D-dimer as- say; bioMérieux SA, RCS Lyon, France)-positive patients. The data have been reconfirmed by our database as not being a re- porting error.

Abstract

We have read with interest the comments made on our study ti- tled ‘Point of care (POC) D-dimer testing in the Emergency de- partment–a bioequivalence study’ [1]. Ekelund and Heilmann, referring to the results and conclu- sions of the study, have suggested that one of the discrepancies may be caused by a typographical error, and this inference prob- ably stems from the use of the term ‘range’ in the published arti- cle. This should have been termed ‘Bland-Altman limits of agree- ment’ (0.24-2.13) for all the cases where both tests were ordered and not just for the 8 POC-negative VIDAS (VIDAS D-dimer as- say; bioMérieux SA, RCS Lyon, France)-positive patients. The data have been reconfirmed by our database as not being a re- porting error.

참고문헌 (11)

  1. Shuhana Perveen, "Point of Care D-Dimer Testing in the Emergency Department: A Bioequivalence Study", Annals of Laboratory Medicine, 33(1), pp.34~38 (2013), 대한진단검사의학회
  2. Vossen JA, "Clinical usefulness of adjusted D-dimer cut-off values to exclude pulmonary embolism in a community hospital emergency department patient population", Acta Radiol, 53, pp.765~768 (2012)
  3. Leng O, "Application of age-adjusted D-dimer threshold for exclusion thromboembolism (PTE) in older patients: a retrospective study", Acute Med, 11, pp.129~132 (2012)
  4. Douma RA, "Potential of an age adjusted D-dimer cut-off value to improve the exclusion of pulmonary embolism in older patients: a retrospective analysis of three large cohorts", BMJ, 340, pp.1475~ (2010)
  5. Douma RA, "Clinical decision rule and D-dimer have lower clinical utility to exclude pulmonary embolism in cancer patients. Explanations and potential ameliorations", Thromb Haemost, 104, pp.831~836 (2010)
  6. Mochizuki S, "Therapeutic significance of a D-dimer cut-off level of >3 μg", ml in colorectal cancer patients treated with standard chemotherapy plus bevacizumab, 2010, pp.40, 933~937
  7. Duriseti RS, "Cost-effectiveness of strategies for diagnosing pulmonary embolism among emergency department patients presenting with undifferentiated symptoms", Ann Emerg Med, 56, pp.321~332 (2010)
  8. Sukhu K, "Comparison of an immuno-turbidometric method (STalia D-DI) with an established enzyme linked fluorescent assay (VIDAS) D-dimer for the exclusion of venous thromboembolism", Int J Lab Hematol, 30, pp.200~204 (2008)
  9. Guideline on the investigation of bioequivalence, "European Medicines Agency", European Medicines Agency, 1~27, pp.CPMP (2010), EWP[DOI]
  10. Bioavailability and bioequivalence studies for orally administered drug products-general considerations, "U.S. Department of Health and Human Services FaDA, Center for Drug Evaluation and Research", U.S. Department of Health and Human Services FaDA, Center for Drug Evaluation and Research, 1~23 (2003)
  11. Obuchowski NA, "Prospective studies of diagnostic test accuracy when disease prevalence is low", Biostatistics, 3, pp.477~492 (2002)

관련 논문AI추천

Point of Care D-Dimer Testing in the Emergency Department: A Bioequivalence StudyAmith Loknath Shetty, Danielle Unwin, Shuhana Perveen대한진단검사의학회 · Annals of Laboratory Medicine2013 · 제33권 제1호Comments on Point of Care D-Dimer Testing in the Emergency Department: A Bioequivalence StudyEric Heilmann, Suzanne Ekelund대한진단검사의학회 · Annals of Laboratory Medicine2014 · 제34권 제1호Can a Point-of-Care Troponin I Assay be as Good as a Central Laboratory Assay? A MIDAS InvestigationAbhinav Chandra, Adam J. Singer, Basmah Safdar, Chadwick D. Miller, Deborah Diercks, Elizabeth Lee-Lewandrowski, Francis Counselman, James Neuenschwander, John Nagurney, Jon Schrock, Joshua Kosowsky, Judd E. Hollander, Mary Peberdy, Richard Nowak, Robert Birkhahn, W. Frank Peacock, William Arnold대한진단검사의학회 · Annals of Laboratory Medicine2016 · 제36권 제5호Performance Evaluation of a Point of Care SelexOnTM B-Type Natriuretic Peptide Immunoassay박해일, 이승옥, 조세운, 최현유, 제갈동욱대한진단검사의학회 · Laboratory Medicine Online2020 · 제10권 제3호Absolute Change in High Sensitivity Cardiac Troponin I for Three Hours is Useful for Diagnosing Acute Myocardial Infarction in the Emergency Department: How to Get to Best Benefit From HS-Troponins in Clinical Practice?Anne Marie Dupuy, Fabien Huet, François Roubille, Jean Paul Cristol대한진단검사의학회 · Annals of Laboratory Medicine2020 · 제40권 제6호D-dimer/troponin ratio in the differential diagnosis of acute pulmonary embolism from non-ST elevation myocardial infarction김계훈, 김종윤, 김주한, 박종춘, 박형욱, 심두선, 안영근, 윤남식, 윤현주, 정명호, 조재영, 조정관, 홍영준대한내과학회 · The Korean Journal of Internal Medicine2019 · 제34권 제6호

이 간행물의 다른 논문 (16건)