Background: Although single antigen bead assays (SAB) are approved qualitative tests, the median fluorescence intensity (MFI) values obtained from SAB are frequently used in combination with quantitative significances for diagnostic purposes. To gauge the reproducibility of SAB results, we assessed the interlaboratory variability of MFI values using identical kits with reagents from the same lot and the manufacturer’s protocol. Methods: Six serum samples containing HLA-specific antibodies were analyzed at five laboratories by using Lifecodes LSA Class I and Class II SAB kits (Immucor, USA) from the same lot, according to the manufacturer’s protocol. We analyzed the concordance of qualitative results according to distinct MFI cutoffs (1,000, 3,000, 5,000, and 10,000), and the correlation of quantitative MFI values obtained by the participating laboratories. The CV for MFI values were analyzed and grouped by mean MFI values from the five laboratories (<1,000; 1,000-2,999; 3,000-4,999; 5,000-9,999; and ≥10,000). Results: The categorical results obtained from the five laboratories exhibited concordance rates of 96.0% and 97.2% for detection of HLA class I and class II antibodies, respectively. The Pearson correlation coefficients for MFI values of class I and class II antibodies were between 0.947-0.991 and 0.992-0.997, respectively. The median CVs for the MFI values among five laboratories in the lower MFI range (<1,000) were significantly higher than those for the other MFI ranges (all P<0.01). Conclusions: Analysis of SAB performed in five laboratories using identical protocols and reagents from the same lot resulted in high levels of concordance and strong correlation of results.
Abstract
Background: Although single antigen bead assays (SAB) are approved qualitative tests, the median fluorescence intensity (MFI) values obtained from SAB are frequently used in combination with quantitative significances for diagnostic purposes. To gauge the reproducibility of SAB results, we assessed the interlaboratory variability of MFI values using identical kits with reagents from the same lot and the manufacturer’s protocol. Methods: Six serum samples containing HLA-specific antibodies were analyzed at five laboratories by using Lifecodes LSA Class I and Class II SAB kits (Immucor, USA) from the same lot, according to the manufacturer’s protocol. We analyzed the concordance of qualitative results according to distinct MFI cutoffs (1,000, 3,000, 5,000, and 10,000), and the correlation of quantitative MFI values obtained by the participating laboratories. The CV for MFI values were analyzed and grouped by mean MFI values from the five laboratories (<1,000; 1,000-2,999; 3,000-4,999; 5,000-9,999; and ≥10,000). Results: The categorical results obtained from the five laboratories exhibited concordance rates of 96.0% and 97.2% for detection of HLA class I and class II antibodies, respectively. The Pearson correlation coefficients for MFI values of class I and class II antibodies were between 0.947-0.991 and 0.992-0.997, respectively. The median CVs for the MFI values among five laboratories in the lower MFI range (<1,000) were significantly higher than those for the other MFI ranges (all P<0.01). Conclusions: Analysis of SAB performed in five laboratories using identical protocols and reagents from the same lot resulted in high levels of concordance and strong correlation of results.
참고문헌 (22)
- Zito A, "Increasing relevance of donor-specific antibodies in antibody-mediated rejection", J Nephrol, 26, pp.237~242 (2013)
- Loupy A, "The impact of donor-specific anti-HLA antibodies on late kidney allograft failure", Nat Rev Nephrol, 8, pp.348~357 (2012)
- Tait BD, "Consensus guidelines on the testing and clinical management issues associated with HLA and non-HLA antibodies in transplantation", Transplantation, 95, pp.19~47 (2013)
- Reinsmoen NL, "Acceptable donor-specific antibody levels allowing for successful deceased and living donor kidney transplantation after desensitization therapy", Transplantation, 86, pp.820~825 (2008)
- 송은영, "Clinical Relevance of Pretransplant HLA Class II Donor-specific Antibodies in Renal Transplantation Patients with Negative T-cell Cytotoxicity Crossmatches", Annals of Laboratory Medicine, 32(2), pp.139~144 (2012), 대한진단검사의학회
- Murphey CL, "Histocompatibility considerations for kidney paired donor exchange programs", Curr Opin Organ Transplant, 17, pp.427~432 (2012)
- Burns JM, "Alloantibody levels and acute humoral rejection early after positive crossmatch kidney transplantation", Am J Transplant, 8, pp.2684~2694 (2008)
- Gloor JM, "Baseline donor-specific antibody levels and outcomes in positive crossmatch kidney transplantation", Am J Transplant, 10, pp.582~589 (2010)
- Aubert V, "Low levels of human leukocyte antigen donor-specific antibodies detected by solid phase assay before transplantation are frequently clinically irrelevant", Hum Immunol, 70, pp.580~583 (2009)
- Cecka JM, "Current methodologies for detecting sensitization to HLA antigens", Curr Opin Organ Transplant, 16, pp.398~403 (2011)
- Archdeacon P, "Summary of FDA antibody-mediated rejection workshop", Am J Transplant, 11, pp.896~906 (2011)
- Tait BD, "Solid phase HLA antibody detection technology–challenges in interpretation", Tissue Antigens, 76, pp.87~95 (2010)
- Gandhi MJ, "Inter and intra laboratory concordance of HLA antibody results obtained by single antigen bead based assay", Hum Immunol, 74, pp.310~317 (2013)
- Tambur AR, "Perception versus reality?: virtual crossmatch–how to overcome some of the technical and logistic limitations", Am J Transplant, 9, pp.1886~1893 (2009)
- Liu C, "Cutoff values and data handling for solid-phase testing for antibodies to HLA: effects on listing unacceptable antigens for thoracic organ transplantation", Hum Immunol, 73, pp.597~604 (2012)
- Wortley A, "Investigations into the lack of consensus in the reporting of HLA antibody specificities in the UK", J Clin Pathol, 62, pp.270~274 (2009)
- Reed EF, "Comprehensive assessment and standardization of solid phase multiplex-bead arrays for the detection of antibodies to HLA", Am J Transplant, 13, pp.1859~1870 (2013)
- Gandhi MJ, "Lot-to-lot variability in HLA antibody screening using a multiplexed bead-based assay", Transfusion, 53, pp.1940~1947 (2013)
- Middleton D, "Nothing’s perfect: the art of defining HLA-specific antibodies", Transplant Immunol, 30, pp.115~121 (2014)
- Bray RA, "Strategies for human leukocyte antigen antibody detection", Curr Opin Organ Transplant, 14, pp.392~397 (2009)
- Zachary A, "Quantifying HLA-specific antibodies in patients undergoingdesensitization", CurrOpinOrgan Transplant, 16, pp.410~415 (2011)
- Waiser J, "Comparison between bortezomib and rituximab in the treatment of antibody-mediated renal allograft rejection", Nephrol Dial Transplant, 27, pp.1246~1251 (2012)