Microtensile bond strength and micromorphologic analysis of surface-treated resin nanoceramics
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
PURPOSE. The aim of this study was to evaluate the influence of different surface treatment methods on the microtensile bond strength of resin cement to resin nanoceramic (RNC). MATERIALS AND METHODS. RNC onlays (Lava Ultimate) (n=30) were treated using air abrasion with and without a universal adhesive, or HF etching followed by a universal adhesive with and without a silane coupling agent, or tribological silica coating with and without a universal adhesive, and divided into 6 groups. Onlays were luted with resin cement to dentin surfaces. A microtensile bond strength test was performed and evaluated by one-way ANOVA and Tukey HSD test (α=.05). A nanoscratch test, field emission scanning electron microscopy, and energy dispersive X-ray spectroscopy were used for micromorphologic analysis (α=.05). The roughness and elemental proportion were evaluated by Kruskal–Wallis test and Mann–Whitney U test. RESULTS. Tribological silica coating showed the highest roughness, followed by air abrasion and HF etching. After HF etching, the RNC surface presented a decrease in oxygen, silicon, and zirconium ratio with increasing carbon ratio. Air abrasion with universal adhesive showed the highest bond strength followed by tribological silica coating with universal adhesive. HF etching with universal adhesive showed the lowest bond strength. CONCLUSION. An improved understanding of the effect of surface treatment of RNC could enhance the durability of resin bonding when used for indirect restorations. When using RNC for restoration, effective and systemic surface roughening methods and an appropriate adhesive are required.
Abstract
PURPOSE. The aim of this study was to evaluate the influence of different surface treatment methods on the microtensile bond strength of resin cement to resin nanoceramic (RNC). MATERIALS AND METHODS. RNC onlays (Lava Ultimate) (n=30) were treated using air abrasion with and without a universal adhesive, or HF etching followed by a universal adhesive with and without a silane coupling agent, or tribological silica coating with and without a universal adhesive, and divided into 6 groups. Onlays were luted with resin cement to dentin surfaces. A microtensile bond strength test was performed and evaluated by one-way ANOVA and Tukey HSD test (α=.05). A nanoscratch test, field emission scanning electron microscopy, and energy dispersive X-ray spectroscopy were used for micromorphologic analysis (α=.05). The roughness and elemental proportion were evaluated by Kruskal–Wallis test and Mann–Whitney U test. RESULTS. Tribological silica coating showed the highest roughness, followed by air abrasion and HF etching. After HF etching, the RNC surface presented a decrease in oxygen, silicon, and zirconium ratio with increasing carbon ratio. Air abrasion with universal adhesive showed the highest bond strength followed by tribological silica coating with universal adhesive. HF etching with universal adhesive showed the lowest bond strength. CONCLUSION. An improved understanding of the effect of surface treatment of RNC could enhance the durability of resin bonding when used for indirect restorations. When using RNC for restoration, effective and systemic surface roughening methods and an appropriate adhesive are required.
참고문헌 (50)
- Alt V, "Fracture strength of temporary fixed partial dentures: CAD", CAM versus directly fabricated restorations, 2011, pp.27, 339~347
- Schoenbaum TR, "Dentistry in the digital age: an update", Dent Today, 31, pp.108~ (2012)
- Poticny DJ, "CAD", CAM in-office technology: innovations after 25 years for predictable, esthetic outcomes, 2010, pp.141, 5S~9S
- Stawarczyk B, "Load-bearing capacity of CAD", CAM milled polymeric three-unit fixed dental prostheses: effect of aging regimens, 2012, pp.16, 1669~1677
- Tinschert J, "Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconiabased ceramics", J Dent, 28, pp.529~535 (2000)
- Stawarczyk B, "Discoloration of manually fabricated resins and industrially fabricated CAD", CAM blocks versus glassceramic:effect of storage media, duration, and subsequent polishing, 2012, pp.31, 377~383
- Stawarczyk B, "Two-body wear rate of CAD", CAM resin blocks and their enamel antagonists, 2013, pp.109, 325~332
- Luthardt RG, "CAD", CAM-machining effects on Y-TZP zirconia, 2004, pp.20, 655~662
- Lin WS, "The effect of core material, veneering porcelain, and fabrication technique on the biaxial flexural strength and weibull analysis of selected dental ceramics", J Prosthodont, 21, pp.353~362 (2012)
- Addison O, "Machining variability impacts on the strength of a ‹chair-side› CAD-CAM ceramic", Dent Mater, 28, pp.880~887 (2012)
- El Zohairy AA, "Microtensile bond strength testing of luting cements to prefabricated CAD", CAM ceramic and composite blocks, 2003, pp.19, 575~583
- "Lava ultimate technical product profile" (2011)[URL]
- Chen C, "The fracture resistance of a CAD", CAM Resin Nano Ceramic (RNC) and a CAD ceramic at different thicknesses, 2014, pp.30, 954~962
- Joda T, "Influence of Abutment Design on Stiffness, Strength, and Failure of Implant-Supported Monolithic Resin Nano Ceramic (RNC)Crowns", Clin Implant Dent Relat Res, 17, pp.1200~1207 (2015)
- Vargas MA, "Cementing all-ceramic restorations: recommendations for success", J Am Dent Assoc, 142, pp.20S~24S (2011)
- Spitznagel FA, "Resin bond to indirect composite and new ceramic", polymer materials: a review of the literature, 2014, pp.26, 382~393
- el-Mowafy O, "The use of resin cements in restorative dentistry to overcome retention problems", J Can Dent Assoc, 67, pp.97~102 (2001)
- Sorensen JA, "Porcelain-composite interface microleakage with various porcelain surface treatments", Dent Mater, 7, pp.118~123 (1991)
- Thompson JY, "Adhesion", cementation to zirconia and other non-silicate ceramics: where are we now?, 2011, pp.27, 71~82
- Semmelman JO, "Silane bonding porcelain teeth to acrylic", J Am Dent Assoc, 76, pp.69~73 (1968)
- Jochen DG, "Composite resin repair of porcelain denture teeth", J Prosthet Dent, 38, pp.673~679 (1977)
- Ferrando JM, "Tensile strength and microleakage of porcelain repair materials", J Prosthet Dent, 50, pp.44~50 (1983)
- Blatz MB, "Resin-ceramic bonding: a review of the literature", J Prosthet Dent, 89, pp.268~274 (2003)
- Ozcan M, "Evaluation of alternative intra-oral repair techniques for fractured ceramic-fused-to-metal restorations", J Oral Rehabil, 30, pp.194~203 (2003)
- Amaral R, "Microtensile bond strength of a resin cement to glass infiltrated zirconiareinforced ceramic: the effect of surface conditioning", Dent Mater, 22, pp.283~290 (2006)
- Ozcan M, "The use of chairside silica coating for different dental applications: a clinical report", J Prosthet Dent, 87, pp.469~472 (2002)
- Bailey LF, "DICOR surface treatments for enhanced bonding", J Dent Res, 67, pp.925~931 (1988)
- Egilmez F, "Effect of surface modification on the bond strength between zirconia and resin cement", J Prosthodont, 22, pp.529~536 (2013)
- Sorensen JA, "Shear bond strength of composite resin to porcelain", Int J Prosthodont, 4, pp.17~23 (1991)
- Chen JH, "Effect of different etching periods on the bond strength of a composite resin to a machinable porcelain", J Dent, 26, pp.53~58 (1998)
- Chen JH, "Effect of etchant, etching period, and silane priming on bond strength to porcelain of composite resin", Oper Dent, 23, pp.250~257 (1998)
- Szep S, "In vitro dentinal surface reaction of 9.5%buffered hydrofluoric acid in repair of ceramic restorations: a scanning electron microscopic investigation", J Prosthet Dent, 83, pp.668~674 (2000)
- Braga RR, "Adhesion to tooth structure: a critical review of “macro” test methods", Dent Mater, 26, pp.e38~e49 (2010)
- Scherrer SS, "Direct comparison of the bond strength results of the different test methods: a critical literature review", Dent Mater, 26, pp.e78~e93 (2010)
- Papia E, "Bonding between oxide ceramics and adhesive cement systems: a systematic review", J Biomed Mater Res B Appl Biomater, 102, pp.395~413 (2014)
- Sano H, "Relationship between surface area for adhesion and tensile bond strength-evaluation of a micro-tensile bond test", Dent Mater, 10, pp.236~240 (1994)
- Pashley DH, "The microtensile bond test: a review", J Adhes Dent, 1, pp.299~309 (1999)
- Blatz MB, "In vitro comparative bond strength of contemporary self-adhesive resin cements to zirconium oxide ceramic with and without air-particle abrasion", Clin Oral Investig, 14, pp.187~192 (2010)
- Soares CJ, "Surface treatment protocols in the cementation process of ceramic and laboratory-processed composite restorations: a literature review", J Esthet Restor Dent, 17, pp.224~235 (2005)
- Borges GA, "Effect of etching and airborne particle abrasion on the microstructure of different dental ceramics", J Prosthet Dent, 89, pp.479~488 (2003)
- Swift EJ Jr, "Treatment of composite surfaces for indirect bonding", Dent Mater, 8, pp.193~196 (1992)
- Kern M, "Sandblasting and silica coating of a glass-infiltrated alumina ceramic: volume loss, morphology,and changes in the surface composition", J Prosthet Dent, 71, pp.453~461 (1994)
- Hantsche H, "Comparison of basic principles of the surfacespecific analytical methods: AES", SAM, ESCA (XPS), SIMS, and ISS with X-ray microanalysis, and some applications in research and industry, 1989, pp.11, 257~280
- Pashley DH, "Adhesion testing of dentin bonding agents: a review", Dent Mater, 11, pp.117~125 (1995)
- Imamura GM, "Enhancement of resin bonding to heat-cured composite resin", Oper De, 21, pp.249~256 (1996)
- Janda R, "A new adhesive technology for all-ceramics", Dent Mater, 19, pp.567~573 (2003)
- Stawarczyk B, "Tensile bond strength of resin composite repair in vitro using different surface preparation conditionings to an aged CAD", CAM resin nanoceramic, 2015, pp.19, 299~308
- D’Arcangelo C, "Effect of three surface treatments on the adhesive properties of indirect composite restorations", J Adhes Dent, 9, pp.319~326 (2007)
- Behr M, "The bond strength of the resin-to-zirconia interface using different bonding concepts", J Mech Behav Biomed Mater, 4, pp.2~8 (2011)
- Lebon N, "Influence of CAD", CAM tool and material on tool wear and roughness of dental prostheses after milling, 2015, pp.114, 236~247
