본문 바로가기
KERD
논문KCI 등재

Simultaneous Screening of 177 Drugs of Abuse in Urine Using Ultra-performance Liquid Chromatography with Tandem Mass Spectrometry in Drug-intoxicated Patients

0

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

Objective: The demand for rapid and broad clinical toxicology screening methods to identify drugs of abuse and medicinal drugs is increasing steadily. Liquid chromatography-tandem mass spectrometry (LC-TMS) is increasingly used to screen for drugs of abuse and to identify a wide range of drugs and metabolites in clinical samples. We revised a high-throughput and rapid ultra-performance (UP) LC-TMS method for simultaneous screening of 177 of the most prevalent medicinal drugs and drugs of abuse in urine and validated the quality of performance using system suitability mixture (SSM) and quality control (QC) materials. Methods: We assessed the limits of detection (LOD) using high concentrations of the test substances. The method was applied to 473 urine samples obtained from patients intoxicated with drugs who visited the emergency center. Results: The retention time, peak area, and total ion chromatogram of the SSM and QC materials were within the acceptance criteria of the pre-defined acceptance interval. The LODs were <62 ng/ml for 12 commonly encountered drugs. In total, 418patients (88.4%) tested positive for one or more medicinal drugs or drugs of abuse. Twenty-eight drugs were detected over ten times; the most commonly detected were zolpidem, ephedrine, paracetamol, and chlorpheniramine. Conclusion: The UPLC-TMS method provided excellent performance for simultaneous screening of a large number of the drugs of abuse in urine samples. We conclude that this robust technique is useful for screening for a large number of drugs and for rapid screening of the most commonly encountered substances in emergency cases.

Abstract

Objective: The demand for rapid and broad clinical toxicology screening methods to identify drugs of abuse and medicinal drugs is increasing steadily. Liquid chromatography-tandem mass spectrometry (LC-TMS) is increasingly used to screen for drugs of abuse and to identify a wide range of drugs and metabolites in clinical samples. We revised a high-throughput and rapid ultra-performance (UP) LC-TMS method for simultaneous screening of 177 of the most prevalent medicinal drugs and drugs of abuse in urine and validated the quality of performance using system suitability mixture (SSM) and quality control (QC) materials. Methods: We assessed the limits of detection (LOD) using high concentrations of the test substances. The method was applied to 473 urine samples obtained from patients intoxicated with drugs who visited the emergency center. Results: The retention time, peak area, and total ion chromatogram of the SSM and QC materials were within the acceptance criteria of the pre-defined acceptance interval. The LODs were <62 ng/ml for 12 commonly encountered drugs. In total, 418patients (88.4%) tested positive for one or more medicinal drugs or drugs of abuse. Twenty-eight drugs were detected over ten times; the most commonly detected were zolpidem, ephedrine, paracetamol, and chlorpheniramine. Conclusion: The UPLC-TMS method provided excellent performance for simultaneous screening of a large number of the drugs of abuse in urine samples. We conclude that this robust technique is useful for screening for a large number of drugs and for rapid screening of the most commonly encountered substances in emergency cases.

참고문헌 (14)

  1. Oiestad EL, "Drug screening of whole blood by ultra-performance liquid chromatography-tandem mass spectrometry", J Anal Toxicol, 35, pp.280~293 (2011)
  2. Lillsunde P, "Comprehensive drug screening in blood for detecting abused drugs or drugs potentially hazardous for traffic safety", Forensic Sci Int, 77, pp.191~210 (1996)
  3. Titier K, "Quantification of tricyclic antidepressants and monoamine oxidase inhibitors by high-performance liquid chromatography-tandem mass spectrometry in whole blood", J Anal Toxicol, 31, pp.200~207 (2007)
  4. Sauvage FL, "A fully automated turbulent-flow liquid chromatography-tandem mass spectrometry technique for monitoring antidepressants in human serum", Ther Drug Monit, 28, pp.123~130 (2006)
  5. Wille SM, "Development of a solid phase extraction for 13 'new' generation antidepressants and their active metabolites for gas chromatographic-mass spectrometric analysis", J Chromatogr A, 1098, pp.19~29 (2005)
  6. Eichhorst JC, "Drugs of abuse testing by tandem mass spectrometry: a rapid, simple method to replace immunoassays", Clin Biochem, 42, pp.1531~1542 (2009)
  7. Sadeg N, "Automated liquid-chromatographic analyzer used for toxicology screening in a general hospital: 12 months' experience", Clin Chem, 43, pp.498~504 (1997)
  8. Adamowicz P, "Simultaneous screening for and determination of 128 date-rape drugs in urine by gas chromatography- electron ionization-mass spectrometry", Forensic Sci Int, 198, pp.39~45 (2010)
  9. Gunnar T, "Validated semiquantitative", quantitative screening of 51 drugs in whole blood as silylated derivatives by gas chromatography-selected ion monitoring mass spectrometry and gas chromatography electron capture detection, 2004, pp.806, 205~219
  10. Maurer HH, "Advances in analytical toxicology: the current role of liquid chromatography-mass spectrometry in drug quantification in blood and oral fluid", Anal Bioanal Chem, 381, pp.110~118 (2005)
  11. Smink BE, "Quantitative analysis of 33 benzodiazepines, metabolites and benzodiazepine-like substances in whole blood by liquid chromatography-(tandem) mass spectrometry", J Chromatogr B Analyt Technol Biomed Life Sci, 811, pp.13~20 (2004)
  12. Maurer HH, "Multi-analyte procedures for screening for and quantification of drugs in blood, plasma, or serum by liquid chromatography-single stage or tandem mass spectrometry (LC-MS or LC-MS", MS) relevant to clinical and forensic toxicology, 2005, pp.38, 310~318
  13. Lynch KL, "Performance evaluation of three liquid chromatography mass spectrometry methods for broad spectrum drug screening", Clin Chim Acta, 411, pp.1474~1481 (2010)
  14. Rosano TG, "Postmortem drug screening by non-targeted and targeted ultra-performance liquid chromatography- mass spectrometry technology", J Anal Toxicol, 35, pp.411~423 (2011)

관련 논문AI추천

이 간행물의 다른 논문 (9건)