본문 바로가기
KERD
논문KCI 등재

A Single Flow Re-direction Endoluminal Device for the Treatment of Large and Giant Anterior Circulation Intracranial Aneurysms

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류의학일반

초록

Purpose: The purpose of this study was to report the author’s experiences in treating large (10–25 mm) and giant (>25 mm) intracranialaneurysms (IAs) using a single Flow Re-direction Endoluminal Device (FRED) without assistant coiling, with a focus onprocedure-related complications. Materials and Methods: A total of 33 patients who were treated with FRED between January 2018 and July 2020 were retrospectivelyreviewed. The timing of procedure-related complications was chronologically categorized as acute (within 7 days), subacute(8 to 21 days), and delayed (after 21 days) periods. Follow-up angiography was performed at 2 to 27 months (mean 9.7months), and clinical follow-up was performed at 1 to 31 months (mean 14.1 months) in all patients. Results: Six (18.2%) patients experienced procedure-related complications, including 2 (6.1%) in acute period, 1 (3.0%) in subacuteperiod, and 3 (9.1%) in delayed period. Thromboembolic complications occurred in 5 (15.2%) patients and hemorrhagiccomplications in 1 (3.0%). Permanent morbidity and mortality rates were 3.0% each. Non-internal carotid artery (ICA) location ofIAs (odds ratio 6.532; 95% confidence interval, 1.335–17.816; p=0.034) was the only independent risk factor for procedure-relatedcomplications on multivariate logistic regression analysis. Conclusion: The procedure-related complication rate was 18.2% in this study. Procedure-related complications might increasewhen treating large and giant IAs located on a non-ICA, especially on the middle cerebral artery. Therefore, it may be suggestedthat neurointerventionists and endovascular neurosurgeons should pay attention to the location of IAs when treating large andgiant IAs with a single FRED.

Abstract

Purpose: The purpose of this study was to report the author’s experiences in treating large (10–25 mm) and giant (>25 mm) intracranialaneurysms (IAs) using a single Flow Re-direction Endoluminal Device (FRED) without assistant coiling, with a focus onprocedure-related complications. Materials and Methods: A total of 33 patients who were treated with FRED between January 2018 and July 2020 were retrospectivelyreviewed. The timing of procedure-related complications was chronologically categorized as acute (within 7 days), subacute(8 to 21 days), and delayed (after 21 days) periods. Follow-up angiography was performed at 2 to 27 months (mean 9.7months), and clinical follow-up was performed at 1 to 31 months (mean 14.1 months) in all patients. Results: Six (18.2%) patients experienced procedure-related complications, including 2 (6.1%) in acute period, 1 (3.0%) in subacuteperiod, and 3 (9.1%) in delayed period. Thromboembolic complications occurred in 5 (15.2%) patients and hemorrhagiccomplications in 1 (3.0%). Permanent morbidity and mortality rates were 3.0% each. Non-internal carotid artery (ICA) location ofIAs (odds ratio 6.532; 95% confidence interval, 1.335–17.816; p=0.034) was the only independent risk factor for procedure-relatedcomplications on multivariate logistic regression analysis. Conclusion: The procedure-related complication rate was 18.2% in this study. Procedure-related complications might increasewhen treating large and giant IAs located on a non-ICA, especially on the middle cerebral artery. Therefore, it may be suggestedthat neurointerventionists and endovascular neurosurgeons should pay attention to the location of IAs when treating large andgiant IAs with a single FRED.

참고문헌 (33)

  1. Gruber A, "Clinical and angiographic results of endosaccular coiling treatment of giant and very large intracranial aneurysms : a 7-year, single-center experience", Neurosurgery, 45, pp.793~803 (1999)
  2. Sluzewski M, "Coiling of very large or giant cerebral aneurysms : long-term clinical and serial angiographic results", AJNR Am J Neuroradiol, 24, pp.257~262 (2003)
  3. van Rooij WJ, "Predictive value of angiographic testing for tolerance to therapeutic occlusion of the carotid artery", AJNR Am J Neuroradiol, 26, pp.175~178 (2005)
  4. Becske T, "Pipeline for uncoilable or failed aneurysms : results from a multicenter clinical trial", Radiology, 267, pp.858~868 (2013)
  5. Becske T, "Long-term clinical and angiographic outcomes following pipeline embolization device treatment of complex internal carotid artery aneurysms : five-year results of the pipeline for uncoilable or failed aneurysms trial", Neurosurgery, 80, pp.40~48 (2017)
  6. Brinjikji W, "Risk factors for ischemic complications following Pipeline embolization device treatment of intracranial aneurysms : results from the IntrePED study", AJNR Am J Neuroradiol, 37, pp.1673~1678 (2016)
  7. Ye G, "Meta-analysis of the efficiency and prognosis of intracranial aneurysm treated with flow diverter devices", J Mol Neurosci, 59, pp.158~167 (2016)
  8. Zhou G, "Efficacy of flow-diverting devices for cerebral aneurysms : a systematic review and meta-analysis", World Neurosurg, 85, pp.252~262 (2016)
  9. Pierot L, "SAFE study(safety and efficacy analysis of FRED embolic device in aneurysm treatment) : 1-year clinical and anatomical results", J Neurointerv Surg, 11, pp.184~189 (2019)
  10. Kallmes DF, "International retrospective study of the pipeline embolization device : a multicenter aneurysm treatment study", AJNR Am J Neuroradiol, 36, pp.108~115 (2015)
  11. Rouchaud A, "Delayed hemorrhagic complications after flow diversion for intracranial aneurysms : a literature overview", Neuroradiology, 58, pp.171~177 (2016)
  12. Lv X, "A systematic review of pipeline embolization device for giant intracranial aneurysms", Neurol India, 65, pp.35~38 (2017)
  13. Sheen JJ, "Microsurgical treatment strategy for large and giant aneurysms of the internal carotid artery", Clin Neurol Neurosurg, 177, pp.54~62 (2019)
  14. O’kelly CJ, "A novel grading scale for the angiographic assessment of intracranial aneurysms treated using flow diverting stents", Interv Neuroradiol, 16, pp.133~137 (2010)
  15. Kallmes DF, "Safety and efficacy of the Pipeline embolization device for treatment of intracranial aneurysms : a pooled analysis of 3 large studies", J Neurosurg, 127, pp.775~780 (2017)
  16. Pumar JM, "Treatment of intracranial aneurysms with the SILK embolization device in a multicenter study. A retrospective data analysis", Neurosurgery, 81, pp.595~601 (2017)
  17. Wakhloo AK, "Surpass flow diverter in the treatment of intracranial aneurysms : a prospective multicenter study", AJNR Am J Neuroradiol, 36, pp.98~107 (2015)
  18. Choi JH, "Treatment outcomes of large and giant intracranial aneurysms according to various treatment modalities", Acta Neurochir(Wien), 162, pp.2745~2752 (2020)
  19. Nossek E, "Concurrent use of the Pipeline embolization device and coils for intracranial aneurysms : technique, safety, and efficacy", J Neurosurg, 122, pp.904~911 (2015)
  20. Oishi H, "Flow diverter therapy using a Pipeline embolization device for 100 unruptured large and giant internal carotid artery aneurysms in a single center in a Japanese population", Neurol Med Chir(Tokyo), 58, pp.461~467 (2018)
  21. Song J, "Antiplatelet drug resistance did not increase the thromboembolic events after stent-assisted coiling of unruptured intracranial aneurysm : a single center experience of 99 cases", Neurol Sci, 38, pp.879~885 (2017)
  22. Gandhi CD, "Platelet function inhibitors and platelet function testing in neurointerventional procedures", J Neurointerv Surg, 6, pp.567~577 (2014)
  23. Bender MT, "P2Y12 hyporesponse(PRU>200)is not associated with increased thromboembolic complications in anterior circulation Pipeline", J Neurointerv Surg, 9, pp.978~981 (2017)
  24. Skukalek SL, "Effect of antiplatelet therapy and platelet function testing on hemorrhagic and thrombotic complications in patients with cerebral aneurysms treated with the pipeline embolization device : a review and meta-analysis", J Neurointerv Surg, 8, pp.58~65 (2016)
  25. Adeeb N, "Use of platelet function testing before pipeline embolization device placement : a multicenter cohort study", Stroke, 48, pp.1322~1330 (2017)
  26. Delgado Almandoz JE, "Pre-procedure P2Y12 reaction units value predicts perioperative thromboembolic and hemorrhagic complications in patients with cerebral aneurysms treated with the Pipeline embolization device", J Neurointerv Surg (2013)
  27. Texakalidis P, "Flow diversion with the pipeline embolization device for patients with intracranial aneurysms and antiplatelet therapy : a systematic literature review", Clin Neurol Neurosurg, 161, pp.78~87 (2017)
  28. Berge J, "Flow-diverter silk stent for the treatment of intracranial aneurysms : 1-year follow-up in a multicenter study", AJNR Am J Neuroradiol, 33, pp.1150~1155 (2012)
  29. Brinjikji W, "Lack of association between statin use and angiographic and clinical outcomes after Pipeline embolization for intracranial aneurysms", AJNR Am J Neuroradiol, 38, pp.753~758 (2017)
  30. Cagnazzo F, "Treatment of middle cerebral artery aneurysms with flowdiverter stents : a systematic review and meta-analysis", AJNR Am J Neuroradiol, 38, pp.2289~2294 (2017)
  31. Lin N, "Treatment of distal anterior circulation aneurysms with the pipeline embolization device : a US multicenter experience", Neurosurgery, 79, pp.14~22 (2016)
  32. Cagnazzo F, "Treatment of distal anterior cerebral artery aneurysms with flow-diverter stents : a single-center experience", AJNR Am J Neuroradiol, 39, pp.1100~1106 (2018)
  33. Cagnazzo F, "Treatment of unruptured distal anterior circulation aneurysms with flow-diverter stents : a meta-analysis", AJNR Am J Neuroradiol, 40, pp.687~693 (2019)

관련 논문AI추천

Feasibility and efficacy of coil embolization for middle cerebral artery aneurysms고준경, 이재일, 이태홍, 최창화, Chae Wook Huh, Jae Young Choi영남대학교 의과대학 · Journal of Yeungnam Medical Science2019 · 제36권 제3호Development of New Endovascular Devices for Aneurysm TreatmentDae Chul Suh, Deok Hee Lee, Hai Bin Shi, Jae Jon Sheen, Joong-Goo Kim, Shigeru Miyachi, Sun Moon Hwang, Yun Sun Song, Zhen Yu Jia대한뇌졸중학회 · 대한뇌졸중영문학회지2018 · 제20권 제1호Clinical Risk Factors Affecting Procedure-Related Major Neurological Complications in Unruptured Intracranial Aneurysms김용배, 서상현, 장이욱, 정준호, 주진양, 홍창기연세대학교의과대학 · Yonsei Medical Journal2015 · 제56권 제4호Long-Term Clinical and Angiographic Outcomes of Wrap- Clipping Strategies for Unclippable Cerebral Aneurysm김용배, 정준호, 주진양, 허승곤, 홍창기연세대학교의과대학 · Yonsei Medical Journal2014 · 제55권 제2호Endovascular Treatment of Ruptured Dissecting Basilar Artery Aneurysm: One Case Report박복환, 변우목영남대학교 의과대학 · Journal of Yeungnam Medical Science2007 · 제24권 제2호Unfavorable Vascular Anatomy during Endovascular Treatment of Stroke: Challenges and Bailout Strategies이진수, Adson Freitas de Lucena, Diego de Almeida Bandeira, Fabricio Oliveira Lima, Felipe de Araújo Rocha, Francisco José Arruda Mont`Alverne, Henrique Coelho Silva, Raul Gomes Nogueira대한뇌졸중학회 · 대한뇌졸중영문학회지2020 · 제22권 제2호

이 간행물의 다른 논문 (11건)