Analysis of Acid Sphingomyelinase Activity in Dried Blood Spots Using Tandem Mass Spectrometry
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Background: Niemann Pick disease (NP) is a rare, lysosomal storage disorder due to deficiency of the intra-lysosomal enzyme acid sphingomyelinase (ASM) resulting in intracellular accumulation of sphingomyelin. We evaluated a tandem mass spectrometry (MS/MS)method to analyze ASM activity in dried blood spots (DBS) that may be suitable for laboratory diagnosis of NP including high throughput screening of at-risk populations and potentially for newborn screening. Methods: ASM activity was measured in 3.2 mm punches from DBS. The eluate was incubated with the ASM substrate (N-Hexanoyl-D-erythro-sphingosylphosphorylcholine [C6- sphingomyelin (C29H59N2O6P)]) and an internal standard (N-butyroyl-D-erythro-sphingosine [C4-ceramide (C22H43NO3)]). ASM product and IS were analyzed using MS/MS in multiple reaction monitoring mode for transitions m/z 370.6>264.3 (ASM internal standard) and m/z 398.6>264.3 (ASM product). Results: ASM activities were stable for up to 2 months at or below 4˚C. Position of the punch in the DBS and/or hematocrit of the DBS had a limited effect on ASM activities. Both intraand inter-assay variability were below 10%. There was no carry-over. The median ASM activity in 2,085 newborn infants was 9.5 μmol/h/L (mean 10.6) with a SD of 5.06 μmol/h/L. Six of 2,085 (0.3%) infants were found to have ASM activities below the cut-off of 2.5 μmol/h/L. ASM activities were below the cut-off level in all 10 previously diagnosed cases with NP (range: 0.16 to 2.08 μmol/h/L). Conclusions: This MS/MS method for the measurement of ASM activity in DBS is robust and suitable for laboratory diagnosis of NP.
Abstract
Background: Niemann Pick disease (NP) is a rare, lysosomal storage disorder due to deficiency of the intra-lysosomal enzyme acid sphingomyelinase (ASM) resulting in intracellular accumulation of sphingomyelin. We evaluated a tandem mass spectrometry (MS/MS)method to analyze ASM activity in dried blood spots (DBS) that may be suitable for laboratory diagnosis of NP including high throughput screening of at-risk populations and potentially for newborn screening. Methods: ASM activity was measured in 3.2 mm punches from DBS. The eluate was incubated with the ASM substrate (N-Hexanoyl-D-erythro-sphingosylphosphorylcholine [C6- sphingomyelin (C29H59N2O6P)]) and an internal standard (N-butyroyl-D-erythro-sphingosine [C4-ceramide (C22H43NO3)]). ASM product and IS were analyzed using MS/MS in multiple reaction monitoring mode for transitions m/z 370.6>264.3 (ASM internal standard) and m/z 398.6>264.3 (ASM product). Results: ASM activities were stable for up to 2 months at or below 4˚C. Position of the punch in the DBS and/or hematocrit of the DBS had a limited effect on ASM activities. Both intraand inter-assay variability were below 10%. There was no carry-over. The median ASM activity in 2,085 newborn infants was 9.5 μmol/h/L (mean 10.6) with a SD of 5.06 μmol/h/L. Six of 2,085 (0.3%) infants were found to have ASM activities below the cut-off of 2.5 μmol/h/L. ASM activities were below the cut-off level in all 10 previously diagnosed cases with NP (range: 0.16 to 2.08 μmol/h/L). Conclusions: This MS/MS method for the measurement of ASM activity in DBS is robust and suitable for laboratory diagnosis of NP.
참고문헌 (8)
- Schuchman EH, "Niemann-Pick Disease Types A and B: acid sphingomyelinase deficiencies, In The metabolic and molecular bases of inherited disease. 8th ed", pp.3589~3610 (2001), McGraw-Hill
- Simonaro CM, "The demographics and distribution of type B Niemann-Pick disease: novel mutations lead to new genotype", phenotype correlations, 2002, pp.71, 1413~1419
- Vanier MT, "Niemann-Pick disease type C", Orphanet J Rare Dis, 5, pp.16~ (2010)
- Schuchman EH, "The pathogenesis and treatment of acid sphingomyelinase-deficient Niemann-Pick disease", Int J Clin Pharmacol Ther, 47(S1), pp.S48~S57 (2009)
- He X, "A fluorescence-based, high-performance liquid chromatographic assay to determine acid sphingomyelinase activity and diagnose types A and B Niemann-Pick disease", Anal Biochem, 314, pp.116~120 (2003)
- Gelb MH, "Direct multiplex assay of enzymes in dried blood spots by tandem mass spectrometry for the newborn screening of lysosomal storage disorders", J Inherit Metab Dis, 29, pp.397~404 (2006)
- Mechtler TP, "Neonatal screening for lysosomal storage disorders: feasibility and incidence from a nationwide study in Austria", Lancet, 379, pp.335~341 (2012)