본문 바로가기
KERD
논문KCI 등재

Perioperative Stroke, In-Hospital Mortality, and Postoperative Morbidity Following Transcatheter Aortic Valve Implantation: A Nationwide Study

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Background and Purpose Perioperative stroke is a significant complication of transcatheter aortic valve implantation (TAVI). This study aimed to quantify perioperative stroke as an independent risk factor for in-hospital mortality and postoperative morbidity in patients receiving TAVI. Methods A retrospective cohort study was conducted using the National Inpatient Sample. Patients undergoing TAVI during 2012 and 2013 were identified using diagnostic codes of International Classification of Diseases, ninth revision. Univariate and multivariate analyses were performed using patient demographics and comorbidities to identify predictors of mortality and morbidity, defined by a length of stay of >14 days and/or discharge to a place other than home. Results Data were obtained from 7,556 patients undergoing TAVI during 2012 and 2013. The incidence rates of mortality and morbidity were 4.57 and 71.12%, respectively. Perioperative stroke was an independent risk factor for mortality [odds ratio (OR)=3.182, 95% confidence interval (CI)=1.530–6.618, p=0.002], as were infection (OR=17.899, 95% CI=9.876–32.440, p< 0.001) and pericardial tamponade (OR=7.272, 95% CI=2.874–18.402, p<0.001). Stroke also predicted morbidity (OR=5.223, 95% CI=2.005–13.608, p=0.001), which was also associated with age, being female, being Asian, moderate and high Van Walraven scores (VWR), and infection. Conclusions In conclusion, perioperative stroke was found to be independently associated with in-hospital mortality and postoperative morbidity, as are age and high VWR. Our findings support the use of further preoperative, intraoperative, and postoperative management strategies during TAVI.

Abstract

Background and Purpose Perioperative stroke is a significant complication of transcatheter aortic valve implantation (TAVI). This study aimed to quantify perioperative stroke as an independent risk factor for in-hospital mortality and postoperative morbidity in patients receiving TAVI. Methods A retrospective cohort study was conducted using the National Inpatient Sample. Patients undergoing TAVI during 2012 and 2013 were identified using diagnostic codes of International Classification of Diseases, ninth revision. Univariate and multivariate analyses were performed using patient demographics and comorbidities to identify predictors of mortality and morbidity, defined by a length of stay of >14 days and/or discharge to a place other than home. Results Data were obtained from 7,556 patients undergoing TAVI during 2012 and 2013. The incidence rates of mortality and morbidity were 4.57 and 71.12%, respectively. Perioperative stroke was an independent risk factor for mortality [odds ratio (OR)=3.182, 95% confidence interval (CI)=1.530–6.618, p=0.002], as were infection (OR=17.899, 95% CI=9.876–32.440, p< 0.001) and pericardial tamponade (OR=7.272, 95% CI=2.874–18.402, p<0.001). Stroke also predicted morbidity (OR=5.223, 95% CI=2.005–13.608, p=0.001), which was also associated with age, being female, being Asian, moderate and high Van Walraven scores (VWR), and infection. Conclusions In conclusion, perioperative stroke was found to be independently associated with in-hospital mortality and postoperative morbidity, as are age and high VWR. Our findings support the use of further preoperative, intraoperative, and postoperative management strategies during TAVI.

참고문헌 (32)

  1. Leon MB, "Transcatheter or surgical aortic-valve replacement in intermediate-risk patients", N Engl J Med, 374, pp.1609~1620 (2016)
  2. Arnold SV, "Predictors of poor outcomes after transcatheter aortic valve replacement: results from the PARTNER (Placement of Aortic Transcatheter Valve) trial", Circulation, 129, pp.2682~2690 (2014)
  3. Rodés-Cabau J, "Long-term outcomes after transcatheter aortic valve implantation: insights on prognostic factors and valve durability from the Canadian multicenter experience", J Am Coll Cardiol, 60, pp.1864~1875 (2012)
  4. Lansky AJ, "A prospective randomized evaluation of the TriGuardTM HDH embolic DEFLECTion device during transcatheter aortic valve implantation:results from the DEFLECT III trial", Eur Heart J, 36, pp.2070~2078 (2015)
  5. Jones BM, "Neurologic events after transcatheter aortic valve replacement", Interv Cardiol Clin, 4, pp.83~93 (2015)
  6. Tchetche D, "Cerebrovascular events post-transcatheter aortic valve replacement in a large cohort of patients: a FRANCE-2 registry substudy", JACC Cardiovasc Interv, 7, pp.1138~1145 (2014)
  7. Reynolds MR, "Cost-effectiveness of transcatheter aortic valve replacement with a self-expanding prosthesis versus surgical aortic valve replacement", J Am Coll Cardiol, 67, pp.29~38 (2016)
  8. Ailawadi G, "Contemporary costs associated with transcatheter aortic valve replacement:a propensity-matched cost analysis", Ann Thorac Surg, 101, pp.154~160 (2016)
  9. Dua A, "Predictors of poor outcome after carotid intervention", J Vasc Surg, 64, pp.663~670 (2016)
  10. Walsh JA, "Risk assessment in patient selection for transcatheter aortic valve replacement", Interv Cardiol Clin, 4, pp.1~12 (2015)
  11. Nwachuku EL, "Diagnostic value of somatosensory evoked potential changes during carotid endarterectomy: a systematic review and meta-analysis", JAMA Neurol, 72, pp.73~80 (2015)
  12. Thirumala PD, "Diagnostic accuracy of EEG changes during carotid endarterectomy in predicting perioperative strokes", J Clin Neurosci, 25, pp.1~9 (2016)
  13. Chimowitz MI, "Stenting versus aggressive medical therapy for intracranial arterial stenosis", N Engl J Med, 365, pp.993~1003 (2011)
  14. Elixhauser A, "Comorbidity measures for use with administrative data", Med Care, 36, pp.8~27 (1998)
  15. Saia F, "Causes and timing of death during long-term follow-up after transcatheter aortic valve replacement", Am Heart J, 168, pp.798~806 (2014)
  16. Xiong TY, "Causes of death following transcatheter aortic valve replacement: a systematic review and meta-analysis", J Am Heart Assoc, 4, pp.e002096~ (2015)
  17. "Online STS adult cardiac surgery risk calculator" (2007)[URL]
  18. "Healthcare Cost and Utilization Project" (2017)[URL]
  19. "Healthcare Cost and Utilization Project" (2017)[URL]
  20. Jilaihawi H, "Meta-analysis of complications in aortic valve replacement: comparison of Medtronic-Corevalve, Edwards-Sapien and surgical aortic valve replacement in 8,536 patients", Catheter Cardiovasc Interv, 80, pp.128~138 (2012)
  21. Patel HJ, "Aortic valve replacement in the moderately elevated risk patient: a population-based analysis of outcomes", Ann Thorac Surg, 102, pp.1466~1472 (2016)
  22. Leon MB, "Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery", N Engl J Med, 363, pp.1597~1607 (2010)
  23. Tamburino C, "Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis", Circulation, 123, pp.299~308 (2011)
  24. Stortecky S, "Cerebrovascular accidents complicating transcatheter aortic valve implantation: frequency, timing and impact on outcomes", Euro-Intervention, 8, pp.62~70 (2012)
  25. Chaturvedi S, "Are the current risks of asymptomatic carotid stenosis exaggerated?: further evidence supporting the CREST 2 trial", JAMA Neurol, 72, pp.1233~1234 (2015)
  26. Arrowsmith JE, "Brain Protection in Cardiac Surgery. Vol 1", pp.83~111 (2011), Springer-Verlag London
  27. Thirumala PD, "Carotid artery disease and periprocedural stroke risk after transcatheter aortic valve implantation", Ann Card Anaesth, 20, pp.145~151 (2017)
  28. Kleiman NS, "Neurological events following transcatheter aortic valve replacement and their predictors: a report from the CoreValve trials", Circ Cardiovasc Interv, 9, pp.e003551~ (2016)
  29. Adams DH, "Transcatheter aortic-valve replacement with a self-expanding prosthesis", N Engl J Med, 370, pp.1790~1798 (2014)
  30. Hemmann K, "The STS score is the strongest predictor of long-term survival following transcatheter aortic valve implantation, whereas access route (transapical versus transfemoral) has no predictive value beyond the periprocedural phase", Interact Cardiovasc Thorac Surg, 17, pp.359~364 (2013)
  31. Mandava P, "A method to determine stroke trial success using multidimensional pooled control functions", Stroke, 40, pp.1803~1810 (2009)
  32. König IR, "Predicting long-term outcome after acute ischemic stroke: a simple index works in patients from controlled clinical trials", Stroke, 39, pp.1821~1826 (2008)

관련 논문AI추천

Recent updates in transcatheter aortic valve implantation김웅, 조정환영남대학교 의과대학 · Journal of Yeungnam Medical Science2018 · 제35권 제1호Transcatheter Aortic Valve Replacement versus Sutureless Aortic Valve Replacement: A Single Center Retrospective Cohort Study이삭, 고영국, 곽영란, 심재광, 심지영, 안철민, 이승현, 정영학, 홍그루, 홍명기연세대학교의과대학 · Yonsei Medical Journal2021 · 제62권 제10호Comparison of Early Clinical Outcomes Following Transcatheter Aortic Valve Implantation versus Surgical Aortic Valve Replacement versus Optimal Medical Therapy in Patients Older than 80 Years with Symptomatic Severe Aortic Stenosis이삭, 임의, 고영국, 곽영란, 김병극, 김중선, 신동호, 심재광, 심지영, 장병철, 장양수, 장혁재, 최동훈, 홍명기연세대학교의과대학 · Yonsei Medical Journal2013 · 제54권 제3호Impact of Atrial Fibrillation on Patients Undergoing Transcatheter Aortic Valve Implantation (TAVI): The K-TAVI Registry권현철, 김원장, 김은경, 김주한, 김준홍, 김지훈, 김효수, 박성지, 박승우, 박종선, 박택규, 박훈식, 안태훈, 양태현, 오성진, 유철웅, 윤영원, 이상록, 이상윤, 이재환, 이한철, 장기육, 채인호, 최기홍, 최병주, 최승혁, 최영진, 최철웅, 허승호연세대학교의과대학 · Yonsei Medical Journal2023 · 제64권 제7호Clinical Outcomes of Transcatheter Aortic Valve Implantation for Native Aortic Valves in Patients with Low Coronary Heights고영국, 김병극, 김중선, 김형수, 심지영, 안철민, 이승준, 장양수, 최동훈, 홍그루, 홍명기, 홍성진연세대학교의과대학 · Yonsei Medical Journal2021 · 제62권 제3호Transcatheter Aortic Valve Replacement with Minimal Contrast Dye in Patients with Renal Insufficiency고영국, 김병극, 김중선, 심지영, 안철민, 장양수, 최동훈, 최자연, 홍그루, 홍명기, 홍성진연세대학교의과대학 · Yonsei Medical Journal2021 · 제62권 제11호