본문 바로가기
KERD
논문KCI 등재

In Vitro Diagnostics Certification for Creatinine Assays in Korea over 7 Years: Achievements and Future Outlook

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류병리학

초록

Background: An international reference measurement laboratory network for creatinine (Cr) is lacking; therefore, Korea developed an independent evaluation and certification system. The in vitro diagnostics (IVD) certification program, launched in 2017, formed part of a broader Cr standardization initiative intended to enhance accuracy at the manufactur- ing stage. Methods: The program was designed to evaluate analytical systems, including all reagent lots, calibrators, and instrument models, twice annually. Bias, imprecision, total error (TE), and linearity were evaluated based on established acceptance criteria. A post-certification process allows submission for a second challenge and validation of corrective actions. Results: Between 2017 and 2023, 489 analytical systems were evaluated. Average ac- ceptance rates for bias, imprecision, TE, and linearity were 70.8%, 95.9%, 87.7%, and 87.8%, respectively. The lowest acceptance rate for bias evaluation was 8.7% for the ki- netic Jaffe method without compensation in 2018. Over the 7-year period, the mean abso- lute percentage bias (absBias%), coefficient of variation (CV), and TE were 4.62%, 1.37%, and 7.29%, respectively. The highest absBias% (7.94%) was observed in the 0.0≤Cr<1.0 target value range. Since 2019, a consistent reduction in absBias% has been observed. Conclusions: This program is a pioneering response to the absence of a global certifica- tion program for Cr assays. It offers significant advantages, including comprehensive eval- uations, fee-free participation, and a robust post-certification process. Continuous partici- pation and improvement efforts by manufacturers have contributed to enhanced accuracy in Cr assays.

Abstract

Background: An international reference measurement laboratory network for creatinine (Cr) is lacking; therefore, Korea developed an independent evaluation and certification system. The in vitro diagnostics (IVD) certification program, launched in 2017, formed part of a broader Cr standardization initiative intended to enhance accuracy at the manufactur- ing stage. Methods: The program was designed to evaluate analytical systems, including all reagent lots, calibrators, and instrument models, twice annually. Bias, imprecision, total error (TE), and linearity were evaluated based on established acceptance criteria. A post-certification process allows submission for a second challenge and validation of corrective actions. Results: Between 2017 and 2023, 489 analytical systems were evaluated. Average ac- ceptance rates for bias, imprecision, TE, and linearity were 70.8%, 95.9%, 87.7%, and 87.8%, respectively. The lowest acceptance rate for bias evaluation was 8.7% for the ki- netic Jaffe method without compensation in 2018. Over the 7-year period, the mean abso- lute percentage bias (absBias%), coefficient of variation (CV), and TE were 4.62%, 1.37%, and 7.29%, respectively. The highest absBias% (7.94%) was observed in the 0.0≤Cr<1.0 target value range. Since 2019, a consistent reduction in absBias% has been observed. Conclusions: This program is a pioneering response to the absence of a global certifica- tion program for Cr assays. It offers significant advantages, including comprehensive eval- uations, fee-free participation, and a robust post-certification process. Continuous partici- pation and improvement efforts by manufacturers have contributed to enhanced accuracy in Cr assays.

관련 논문AI추천

Recent Trends in Creatinine Assays in Korea: Long-Term Accuracy-Based Proficiency Testing Survey Data by the Korean Association of External Quality Assessment Service (2011–2019)Cho Eun-Jung, Chun Sail, Jeong Tae-Dong, Lee Kyunghoon, Lee Woochang, Min Won-Ki, Song Junghan, Yun Yeo-Min대한진단검사의학회 · Annals of Laboratory Medicine2021 · 제41권 제4호Siemens CRE2 시약의 Creatinine 측정 수행능 평가구선회, 권계철, 김선영, 김지명, 김현진, 임진숙대한진단검사의학회 · Laboratory Medicine Online2019 · 제9권 제1호Jaffe법과 효소법으로 측정한 Roche Modular D, Cobas 8000 c702 및 Beckman Coulter AU5800 장비 간의 혈청 Creatinine 비교박형두, 오종원대한진단검사의학회 · Laboratory Medicine Online2020 · 제10권 제1호Standardization Status of Total Cholesterol Concentration Measurement: Analysis of Korean External Quality Assessment DataChun Sail, Kim Sollip, Lee Kyunghoon, Lee Yong-Wha, Min Won-Ki, Park Hyung-Doo, Yoon Young Ahn대한진단검사의학회 · Annals of Laboratory Medicine2021 · 제41권 제4호Quantitative Evaluation of the Real-World Harmonization Status of Laboratory Test Items Using External Quality Assessment Data김솔잎, 송정한, 전사일, Cho Eun-Jung, Chung Jae-Woo, Jeong Tae-Dong, Lee Kyunghoon, Lee Seunghoo, Min Won-Ki대한진단검사의학회 · Annals of Laboratory Medicine2024 · 제44권 제6호Schemes and Performance Evaluation Criteria of Korean Association of External Quality Assessment (KEQAS) for Improving Laboratory TestingChun Sail, Kim Sollip, Lee Kyunghoon, Lee Yong-Wha, Min Won-Ki, Park Hyung-Doo대한진단검사의학회 · Annals of Laboratory Medicine2021 · 제41권 제2호

이 간행물의 다른 논문 (11건)