Foreign Body Removal in Children Using Foley Catheter or Magnet Tube from Gastrointestinal Tract
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
Foreign body (FB) ingestion of children is a common pediatric emergency requiring medical attention. Pediatric emergency physicians and gastroenterologists often encounter nervous and distressed situations, because of children presenting with this condition in the common clinical practice. When determining the appropriate timing and indications for intervention, physicians should consider multiple patient- and FB-related factors. The utilization of a flexible endoscopy is considered safe and effective to use in these cases, with a high success rate, for the effective extraction of FBs from the gastrointestinal tract of a child. Additionally, a Foley catheter and a magnet-attached Levin tube have been used for decades in the case of FB removal. Although their use has decreased significantly in recent times, these instruments continue to be used for several indications. Using a Foley catheter for this purpose does not require special training and does not necessarily require sedation of the patient or fluoroscopy, which serve as advantages of utilizing this method for foreign object retrieval. An ingested magnet or iron-containing FB can be retrieved using a magnet-attached tube, and can be effective to retrieve an object from any section of the upper gastrointestinal tract that can be reached. Simple and inexpensive devices such as Foley catheters and magnetattached tubes can be used in emergencies such as with the esophageal impaction of disk batteries if endoscopy cannot be performed immediately (e.g., in rural areas and/or in patients presenting at midnight in a facility, especially in those without access to endoscopes or emergency services, or in any situation that warrants urgent removal of a foreign object).
Abstract
Foreign body (FB) ingestion of children is a common pediatric emergency requiring medical attention. Pediatric emergency physicians and gastroenterologists often encounter nervous and distressed situations, because of children presenting with this condition in the common clinical practice. When determining the appropriate timing and indications for intervention, physicians should consider multiple patient- and FB-related factors. The utilization of a flexible endoscopy is considered safe and effective to use in these cases, with a high success rate, for the effective extraction of FBs from the gastrointestinal tract of a child. Additionally, a Foley catheter and a magnet-attached Levin tube have been used for decades in the case of FB removal. Although their use has decreased significantly in recent times, these instruments continue to be used for several indications. Using a Foley catheter for this purpose does not require special training and does not necessarily require sedation of the patient or fluoroscopy, which serve as advantages of utilizing this method for foreign object retrieval. An ingested magnet or iron-containing FB can be retrieved using a magnet-attached tube, and can be effective to retrieve an object from any section of the upper gastrointestinal tract that can be reached. Simple and inexpensive devices such as Foley catheters and magnetattached tubes can be used in emergencies such as with the esophageal impaction of disk batteries if endoscopy cannot be performed immediately (e.g., in rural areas and/or in patients presenting at midnight in a facility, especially in those without access to endoscopes or emergency services, or in any situation that warrants urgent removal of a foreign object).
참고문헌 (40)
- Seo JK, "Endoscopic removal of gastrointestinal foreign bodies in 3 newborn infants immediately after birth", Korean J Gastrointest Endosc, 18, pp.87~91 (1998)
- Choe BH, "Endoscopic removal of foreign bodies from the upper gastrointestinal tract in children : management of 78 cases in Taegu, Korea", Korean J Gastrointest Endosc, 20, pp.6~13 (2000)
- Gummin DD, "2016 Annual Report of the American Association of Poison Control Centers' National Poison Data System (NPDS): 34th annual report. Clin Toxicol (Phila)", Clin Toxicol(Phila), 55, pp.1072~1252 (2017)
- Choe BH, "Rescue of child with accidental overingestion of iron tablets by gastroscope", Korean J Gastrointest Endosc, 17, pp.801~805 (1997)
- Tringali A, "Pediatric gastrointestinal endoscopy : European Society of Gastrointestinal Endoscopy(ESGE)and European Society for Paediatric Gastroenterology Hepatology and Nutrition(ESPGHAN)Guideline executive summary", Endoscopy, 49, pp.83~91 (2017)
- 김정옥, "디스크 전지를 삼킨 소아에서내시경적 이물 제거술의 비교", Pediatric Gastroenterology, Hepatology & Nutrition, 10(2), pp.147~156 (2007), 대한소아소화기영양학회
- Seo JK, "Endoscopic management of gastrointestinal foreign bodies in children : a clinical practice guideline", Korean J Pediatr Gastroenterol Nutr, 10, pp.64~69 (2007)
- 강지현, "소아의 식도 동전 제거에서 내시경 전에 시도한Foley 카테터의 유용성", Pediatric Gastroenterology, Hepatology & Nutrition, 14(3), pp.251~257 (2011), 대한소아소화기영양학회
- Joyamaha D, "Managing pediatric foreign body ingestions", Mo Med, 112, pp.181~186 (2015)
- Conners GP, "Foley catheter and esophageal foreign bodies", Pediatrics, 96, pp.791~ (1995)
- 이준희, "Foreign Body Ingestion in Children: Should Button Batteries in the Stomach Be Urgently Removed?", Pediatric Gastroenterology, Hepatology & Nutrition, 19(1), pp.20~28 (2016), 대한소아소화기영양학회
- Kramer RE, "Management of ingested foreign bodies in children : a clinical report of the NASPGHAN Endoscopy Committee", J Pediatr Gastroenterol Nutr, 60, pp.562~574 (2015)
- Magalhães-Costa P, "Endoscopic management of foreign bodies in the upper gastrointestinal tract : an evidence-based review article", GE Port J Gastroenterol, 23, pp.142~152 (2015)
- Bigler FC, "The use of a Foley catheter for removal of blunt foreign bodies from the esophagus", J Thorac Cardiovasc Surg, 51, pp.759~760 (1966)
- Macpherson RI, "Esophageal foreign bodies in children : diagnosis, treatment, and complications", AJR Am J Roentgenol, 166, pp.919~924 (1996)
- Agarwala S, "Coins can be safely removed from the esophagus by Foley's catheter without fluoroscopic control", Indian Pediatr, 33, pp.109~111 (1996)
- Little DC, "Esophageal foreign bodies in the pediatric population : our first 500 cases", J Pediatr Surg, 41, pp.914~918 (2006)
- Mariani PJ, "Foley catheter extraction of blunt esophageal foreign bodies", J Emerg Med, 4, pp.301~306 (1986)
- Stack LB, "Foreign bodies in the gastrointestinal tract", Emerg Med Clin North Am, 14, pp.493~521 (1996)
- Conners GP, "A literature-based comparison of three methods of pediatric esophageal coin removal", Pediatr Emerg Care, 13, pp.154~157 (1997)
- Schunk JE, "Fluoroscopic foley catheter removal of esophageal foreign bodies in children : experience with 415 episodes", Pediatrics, 94, pp.709~714 (1994)
- Towbin R, "Esophageal edema as a predictor of unsuccessful balloon extraction of esophageal foreign body", Pediatr Radiol, 19, pp.359~360 (1989)
- McGuirt WF, "Use of Foley catheter for removal of esophageal foreign bodies. A survey", Ann Otol Rhinol Laryngol, 91, pp.599~601 (1982)
- Equen M, "A new magnet for foreign bodies in the food and air passages", JAMA, 127, pp.87~88 (1945)
- Silber S, "The peroral removal of certain swallowed foreign bodies without endoscopy; introducing a new device utilizing the alnico magnet", N Y State J Med, 47, pp.1122~1124 (1947)
- Kuhns DW, "Button battery ingestions", Ann Emerg Med, 18, pp.293~300 (1989)
- McDermott VG, "Orogastric magnet removal of ingested disc batteries", J Pediatr Surg, 30, pp.29~32 (1995)
- Volle E, "Therapeutic approach to ingested button-type batteries. Magnetic removal of ingested button-type batteries", Pediatr Radiol, 19, pp.114~118 (1989)
- Mowry JB, "2014 Annual Report of the American Association of Poison Control Centers' National Poison Data System (NPDS): 32nd annual report", Clin Toxicol (Phila), 53, pp.962~1147 (2015)
- Talvard M, "Magnet ingestions in children : a French multicenter study", Arch Pediatr, 22, pp.32~38 (2015)
- Waters AM, "Surgical management and morbidity of pediatric magnet ingestions", J Surg Res, 199, pp.137~140 (2015)
- Agbo C, "Magnet-related injury rates in children : a single hospital experience", J Pediatr Gastroenterol Nutr, 57, pp.14~17 (2013)
- Strickland M, "Magnetic foreign body injuries : a large pediatric hospital experience", J Pediatr, 165, pp.332~335 (2014)
- Arana A, "Management of ingested foreign bodies in childhood and review of the literature", Eur J Pediatr, 160, pp.468~472 (2001)
- Volle E, "Removal of swallowed metallic foreign bodies by orogastric magnetic intubation", Z Kinderchir, 42, pp.346~349 (1987)
- Volle E, "Ingested foreign bodies : removal by magnet", Radiology, 160, pp.407~409 (1986)
- Kim MK, "Clinical evaluation of foley catheter technique for removal of blunt esophageal foreign bodies", Korean J Otolaryngol-Head Neck Surg, 28, pp.793~795 (1985)
- Ham PB 3rd, "Analysis of 334 cases of pediatric esophageal foreign body removal suggests that traditional methods have similar outcomes whereas a magnetic tip orogastric tube appears to be an effective, efficient, and safe technique for disc battery removal", Am Surg, 84, pp.1152~1158 (2018)
- Kim GW, "Removal of esophageal blunt foreign bodies by using a foley balloon catheter in the emergency department", J Korean Soc Emerg Med, 12, pp.359~368 (2001)
- Dokler ML, "Selective management of pediatric esophageal foreign bodies", Am Surg, 61, pp.132~134 (1995)