공기청정기의 현장적용평가를 통한 의료기관 내 공기오염물질 저감효율 파악
Identification of air contaminants removal efficiency in medical institution through field application evaluation of air cleaner
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
According to a recent report on indoor air quality map conducted by the Ministry of Environment (2016-2017), the importance of indoor air quality in hospitals has emerged, with total airborne bacteria (82.3% and 149 cases) showing the highest number of facilities exceeding maintenance standards by contaminant. In particular, interest in the hospital environment is increasing as it is the living space of patients who are mostly vulnerable to pollutants. This study introduced an air purifier with decontamination function within the hospital facility, and the site application evaluation of the air purification system is given as a table of contents. The measurement items for the site application evaluation are fine dust, gross airborne bacteria, fungi, temperature and humidity, and the measuring equipment for each item is grimm dust spectrometer (model 1.108), Mars-100, and HOBO MX 1101. In the case of fine dust, the variation of fine dust can be seen through the measurement of the mining equation, and in the case of floating microorganisms (total airborne bacteria, bear Pangi) the impact method specified in the indoor air quality process test standards was collected, cultivated and quantified. Data were collected for conversion to CFU by counting after incubation of bioaerosol in case of temperature and humidity. The reduction efficiency is presented by comparing data before and after operation of the air purifier
Abstract
According to a recent report on indoor air quality map conducted by the Ministry of Environment (2016-2017), the importance of indoor air quality in hospitals has emerged, with total airborne bacteria (82.3% and 149 cases) showing the highest number of facilities exceeding maintenance standards by contaminant. In particular, interest in the hospital environment is increasing as it is the living space of patients who are mostly vulnerable to pollutants. This study introduced an air purifier with decontamination function within the hospital facility, and the site application evaluation of the air purification system is given as a table of contents. The measurement items for the site application evaluation are fine dust, gross airborne bacteria, fungi, temperature and humidity, and the measuring equipment for each item is grimm dust spectrometer (model 1.108), Mars-100, and HOBO MX 1101. In the case of fine dust, the variation of fine dust can be seen through the measurement of the mining equation, and in the case of floating microorganisms (total airborne bacteria, bear Pangi) the impact method specified in the indoor air quality process test standards was collected, cultivated and quantified. Data were collected for conversion to CFU by counting after incubation of bioaerosol in case of temperature and humidity. The reduction efficiency is presented by comparing data before and after operation of the air purifier
참고문헌 (7)
- 이복진, "중량법과 베타선 흡수법을 이용한 온라인 광산란 미세먼지 측정기의 PM10과 PM2.5의 정확도 평가", 한국대기환경학회지, 35(3), pp.357~369 (2019), 한국대기환경학회[DOI]
- 송용우, "기류분석을 통한 종합병원(외래)진료부의 공기 감염 개선 연구", 설비공학 논문집, 31(6), pp.246~257 (2019), 대한설비공학회[DOI]
- 조용민, "미세먼지 노출에 의한 건강영향과 공기청정기의 효율적 사용", 의료정책포럼, 12, pp.45~54 (2014)
- 김기연, "종합병원의 실내공기에 분포하는 부유 세균과 진균의 입경별 종류와 특성", 한국산업보건학회지, 16(2), pp.101~109 (2006), 한국산업보건학회
- 강선행, "제3주제: 병원 실내공기질 향상 방안", 대한환경위생공학회 정기총회 및 학술발표회, pp.25~30 (2008)
- 고효율필터(HEPA Filter) 폐기물의 저준위화 및 감용 기술현황, "최왕규", 한국원자력연구원, 3~16 (2010)
- 노광철, "병원 환기량 및 필터효율에 따른 병실미생물 농도 예측", 대한설비공학회 학술발표대회논문집, pp.1176~1179 (2011)