발전소 온배수 난방시스템을 적용한 아열대과수의 생육정보에 대한 연구
A Study on the Growth Information of Subtropical Fruit Trees using Power Plant Thermal Effluent Heating System
0
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
We conducted a study on the possibility of using the power plant's thermal effluent system by using a heating system to utilize the thermal effluent from Jeju Power Headquarters of KOMIPO. In this study, growth information such as the size, leaf area, fresh weight and dry weight of subtropical persimmon fruit (A) in the facility cultivation complex were measured. In the comparison group (B), the growth information of the same crop was measured and compared in an unheated greenhouse near Harye-ri, Namwon-eup, Seogwipo. Fruit size was measured at monthly intervals, and leaf area, fresh weight, and dry weight were measured at new shoot season. Measurement results of A and B growth information, 1) Fruit diameter & length, A grew 7.3% and 9.4% than B, 2) Leaf area, A grew 4.7% than B, 3) Fresh weight, the decrease was 8.9%, but the dry weight was 3.6%, indicating that A contains more nutrients than B. Therefore, if the heating control by supplying thermal effluent to the facility greenhouse, it can contribute to reducing the energy cost and improving quality.
Abstract
We conducted a study on the possibility of using the power plant's thermal effluent system by using a heating system to utilize the thermal effluent from Jeju Power Headquarters of KOMIPO. In this study, growth information such as the size, leaf area, fresh weight and dry weight of subtropical persimmon fruit (A) in the facility cultivation complex were measured. In the comparison group (B), the growth information of the same crop was measured and compared in an unheated greenhouse near Harye-ri, Namwon-eup, Seogwipo. Fruit size was measured at monthly intervals, and leaf area, fresh weight, and dry weight were measured at new shoot season. Measurement results of A and B growth information, 1) Fruit diameter & length, A grew 7.3% and 9.4% than B, 2) Leaf area, A grew 4.7% than B, 3) Fresh weight, the decrease was 8.9%, but the dry weight was 3.6%, indicating that A contains more nutrients than B. Therefore, if the heating control by supplying thermal effluent to the facility greenhouse, it can contribute to reducing the energy cost and improving quality.
참고문헌 (5)
- 김은정, "발전시설과 온배수 관리를 위한 제도 개선에 관한 연구", 환경법과 정책, 21, pp.79~100 (2018), 비교법학연구소[DOI]
- "UN Convention on the Law of the Sea", ~ (1994)
- 이연건, "제주 시설온실 냉난방을 위한 발전소 온배수 활용 열펌프 시스템 구축 및 냉방성능 평가", 에너지공학, 27(4), pp.70~79 (2018), 한국에너지학회
- 김연중, "발전소 온배수를 활용한 온・열대 신선과일 수입대체 정책 방안", 한국산학기술학회논문지, 18(10), pp.48~53 (2017), 한국산학기술학회[DOI]
- "Nongsaro"[URL]